72 CHAMPLAIN ROAD - BUILDING JACKET cl . M �tf'i" r , FEB �F) 28 �t� �++tre Drpartmettt 7.4rabquarters ,�fatnee X. ,Srennxn CITY OF SALEM,MASS• 4 5i �t . Date FP ,,,a L, 19Z8 Names Lucy icy i fou rp Res 72 Champlain Rd yli.�tl Addresss 72 Champlain Road, Salem, Ma. Salem, Ma. As a result of an inspection this date of the premises, structureV. ` : open land area or vehicle owned, occupied or otherwise under your `efx'` control, the following recommendations are submitted and shall ee" ' ' as a notice of violation of fire laws. These recommendations are fico' made in the interest of fire prevention and to correct conditions ' ' that that are or may become dangerous as a fire hazard or are in violat" 0 of law. You are hereby notified to remedy said violations named below �l 44` within a reasonable time of the above date, / Such furthur action will be taken as the law requires, for failure M to comply with the above requirements within the stipulated time. " (Reference: s >r..era1 Taws of Commonwealth of P:lassachusetts,. Chapter,.y248, Section 30, and the Salem Fire Code .Article l. ) Recent blow batik of oil burner and start of serious partition fire on 2/14/78 y" at 0228 caused serious concern to Cn-duty Deputy chief Robert Crowley and a request of Fire Prevention Bureau to follow up complaint on this oil burtAmrig .`' furnace. , 1. Basement has numerous violations. It appears this property is being used as a two-family occupancy without proper exits out of basement apartirent:' 2. In my opinion this lennox furnace and burner has been altered from`;. . s <+ original installation. Apparent lack of approved controls on burner. thermal cut-off above unit. Fuel tank could not be located, was told 275 ,E gallon tank was outside building, which is not an approved installation. , .i Wooden enclosure surrounds furnace boxing unit in. combustible rated partition to replace what is now present., Lack of fresh air in enclosed furnace .roam has added to improper combustion of this heating.unit. " 3. No further repairs to this unit will be pa permitted as it does not with provisions of FPR #3. Automatic damper on flue pipe shows evidence of having been locked in open position. Heavy coating of soot shows {' that gases and fumes never reached chimney and ware vented in basement. * '` Chimney cleanout had broken bricks and debris inside. Building Inspector will have to evaluate this condition. 4. It appears wiring in basement does not meet code requirements. Further investigation by Electrical Inspector required. . S. 'Gas installation of domestic hot water heating unit appears improper and exhaust of this unit seems to empty inside building. Gas Inspector to � reinspect same. � ." - - , �•:. co. Elec. IInnsp. Nr. Condon Gas Inspector ��or nc Dansreau, Sa em Fire Dept File k" V' l `� c