14 PATTON RD - BUILDING INSPECTION . � ' . q. ,F � , �. (���I� � The Commonwealth of Massachusetts . ,• �F'� J °„1,. Board of Building Regulations and Standazds CITY OF Q �` Massachusetts State Building Code,780 CMR SALEM Revised Mar 20!1 Building Permit Application To Construct, Repair, Renovate Or Demolish a ' One- or Two-Family Dwelling � This Section For Official Use Only , � Building Permit Number. ate Applied: ... � � A�,,� 1� .����e,,.�. !L�,�., ' �/n Building Official(Print Name) Signatu � Date , � SECTION 1: S[TE INFO � TION � t.l Property Address: 1.2 Assessors Map& Parcel Numbers 1�1 �t er� KOqd , 1.1 a Is this an accepted stt'eet?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions. � . Zoning District Proposed Use Lot Area(sq ft) Frontage(R) 1.5 Building Setbacks(ft) Front Yard . Side Yards Rear Yard Required Provided Required Provided� Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1,8 Sewage Disposal System: ' , Public❑ Private❑ Zone: _ Outside Plood Zone? Municipal ❑ On site disposal system ❑ . �Check if yesO SECTION 2: PROPERTY OWNERSHIP� 2.1 Owner�of Record: �n;ctiae� Cq9a iano So%.., /�1¢, o�47a am� e(Print) �� . . _ City,State,ZIP /4/ Po ffbn �oad g7S- 7S�o-/obU No.and Street �. Telephone - 8mail Address � . SECTION 3: DESCR1PTlON OF PROPOSED WORK=(check all[hat apply) New Constmetion ❑ Existing Building❑ OwnerOccupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition 0 � Demolition ❑ Accessory Bldg. ❑ � Number of Units Other � Specify: V � BriefDescriptionofProposedWorkZ: *..rSf9// 0�6 So/4r B/CC.�riL �O4✓/B/s On - o Of i ; orn e C i fr cOs�n e ed �v: h � o�,s e P/�f.�ico / Su f errr . V SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials 1.Building $ � 7 p �D 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee o� "U 00 ❑Total Projec[Cost (Item 6)x moltiplier x 3.Plumbing $ 2. Other Fees: $ . . 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ � � Su ression Total All Fees: $ Check No. Check Amount: Cash AmounY. � 6.Total Projeet Cost: $ , 3— v G� ❑paid in Full ❑ Outstanding Balance Due: �� , � ��' �.�T �il ��l �� �,-T /d ���T� �D�(�� C.%`T/ �aG�� i%�/f,��fJd � � Yf�//L�. � > ; , SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 9a�' 97 ii Ib�.k,i3 LeS�e� Lv� 6�- �S�L LicenseNumber ExpirationDate Name of CSL Holder � . � Lis[CSL Type(see below) l� I o`RwHScr �- i rc, �C o.and Stree Type Description U Unrestricted(Buildin s u to 35,000 cu.ftJ g b �AI Q4 vvti o U '� �l. 1M4 O o1�9 D R Restricted I&2 Famil Dwellin C�ty/Town,St te,ZIP M Mason RC Roofin Coverin � . WS WindowandSidin � � - SP Solid Puel Buming Appliances � scfr3tro-vabg �aw��k �So�RfCi�{n. �LOvn I Insulation Tele hone � Gmail ad ress D Demolilion 5.2 Registered Home Improvement Contractor(HIC) �L SS 7� 3/b/ao�3 c�a1Qf�.;a,.co,��. /Les�e� � . G�i 1�' �_ HIC Registration Number Expiration Da[e �I�Cso�an�r HIC Registrant Name � � � �►nwr+r� s+ elaa� lJn'� k �� Da,:/te2b/ �"� No.and Street 4.^ � i G f)o+'� Marl �poVtavak M4.p/7Sd- S'ox��o-4��9 Bmailaddress _ Cit /Town,State,ZIP Tele hone � SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted wi[h this application.�Failure ro provide this affidavit will resul[in the denial of the Issuance of the building permi[. Signed Affidavit Attached? Yes ..........� No ...........❑ � SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject proper[y,hereby au[horize L e�}G r E. Lfi.'�� V�. - to act on my behalf, in all matters relative to work authorized by this building permit application. Print Owner's Name(Electronic Signamre) � Uate SECTION 7b: OWNER�OR AUTHORIZED AGENT DECLARATION � By en[ering my name below, I hereby attest under[he pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. L�S�ic� �G.;/-l-5�. �e�. GP� �/� �s, � /o ao/a Prin[ wner's or Authorized AgenPs Name(Electronic Signature) � Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered con[rac[or � ' (no[regis[ered in the Home Improvemen[Contractor(HIC)Program),will nof have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important infortnation on the HIC Program can be found at www.mass. o� v/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps � 2. When substantial work is planned,provide the infortnation below: Total floor area(sq.ft.) � (including garage,finished basemenUattics,decks or porch) Gross living area(sq.ft.) Habitable room count . � Number of fireplaces Number of bedrooms � Number of bathrooms Number of half/baths Type of heating�system Number of decks/porches . Type of cooling system � Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Projec[CosP' ��eey " „ ��=��SolarCity Nolan Richardson � Permit Runner . r (888)765-2489 x2358 � m p74)2ffi-0769 r (508)460-0318 - nrichardson�solarc ity.com I� � ,f�� �:� . � �;, a. . . � � . � � .i�,., .�::;. � �:.�f • 1 a.i . 1 ��'� ✓l?,F; �U�'fl�/1?/!'!?.(aO2l.Ul�,.t�'.l�L ,fJj�• i./!/t.<.xdJf",1',!'�loP.�,� - ' OJiice of Consumer �111`�u�s aa�d Busin.ess Regulat�on j`Pye� 10 Park Plaza - Suite 5170 � Boston, Massachusetts 02116 �Iome Improvement Contractor Registration Repisiration: 188572 , � _ Type: Supplement Card Expiratlon: 3/6/2073 SOLARCITY CORPORATION LESTER WILT JR. 17 STERLING RD. BELLERICA, MA 01821 , Updafe Addresa and return cerd.Merk reaeon for change. � � � Address � Renewal � Employment [� Y.ostCard >rs.ce� t� swnoaroa.cuoi�m �/�C ��09Nf��OVeNKY/l�� t��� ����IOtYIII.HI��d - �='+ Om�e of l:oueumer Affafre bi Buaioese Regulalloo License or registration valid for individul uae only � ��,���MOME7MPROVEPAEMT COPIYRACTOR � before the expirallon dete. IP Pound return to: O�ce of Consumer Affairs and Busineas Regulation Registraqon: �gg572 �YPO- 10 Park Plaze-Suite 5190 Expiratlon: ;i/B/2093 Supplement Cerd Boston,N1A 02116 SOLARCITY CORPORATION . � � LESTER WILT JR. . �- G� Q� ��� ���(�/' 3055 CLEARVIEW WAX �`��.-��- "q' l ��"�t • SAN MATEO,CA 94402 � ' Undersecrctary Plot valid without signeture \I;u.:iclnisi•tl. - Dc��nrinn•iii ul'1'u1Hi�� tiuli•n � � � )p Iluard ul' Buildin7l Itcs:ul:��inn� and �I��ud�ird. � � ��{. Conxlructicin ti�q�r,�visoi 1 ir.enso . � � 1 ican!.c: CS 92597 . � c_ . ` .. . . � : � . 1 ql �:�rt ' LESTERE WILTJid ��i:'�,� 10 RAtdGER CIRCLE �(' +:�+ • u' � SO WEYMOUTH, MA 02990 "`" �"`� " i ' �T,.G- -d.�yE i A��Iralinn: 17/B/2073 � . .��.t ,nnmi.,i�m�.r.•...— tNh 7422 . . � ' � ` ° T�e Commonwealth ofMnssachusetts Print Form Department ofindustrial Accidents ' D�ce oflnvestigations ' 1 Congress Street, Suite.l DO Boston,MA 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Le�iblv Name (Business/Organization/[ndividuaq;$olarCity Corporation _ Address:3055 Clearview Way Cily/StatclZip:San Mateo, CA 94402 Phone#:650 963-5100 Are you an employer?Check the appropriate box: Type of project(required): I.❑� [am a employer with �500 4. Q I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.❑ I am a sole proprietor or paitner- ��sted on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g, � Demolition working for me in any capacity, employees and have wotkers' 9. ❑ Building addition [No workets' comp. insurance comp. insurance.= required.] 5. � We are a corporation and its 10.❑ Elecuical repairs or additions 3.0 [ am a homeowner doing ali work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4), and we have no Solar Installation employees. [No workers' 13.❑� Other comp. insurance required.] •Any applicent[hat checks box#1 must elso fill out the seclion below showing their workers'compensation policy info�mation. t Homeowners who submit Ihis affidavil indicating ihey ere doing all work and then hice outside contractors must submit a new a�davi[indicati�g such. =Contractors[hat check this box must attached an addi[ional sheet showing the neme of the sub-contracrors end state whether or mt those entities have� employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer lhat is providing warkers'compensation insurance jor my emp[oyees. Below is the policy and job site infnrmation. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins. Lic. #wC96734670 Expiration Date:9�01/2012 Job Site Address: / �� Yq�/On �04e� CitylState/7ip:�q�� /{�/,�,D/�JQ Attach a copy of the workers' wmpensation policy declaration page(showing t6e policy number and ezpiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead[o the imposition of criminal penalties of a fine up to$1,SOO:OOand/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereLy cerJi v under the in'ra*-m d � i nllies n '�c�r'ar�that the i�r brimr(ion provided above is true and correct. _ _ �,��,f,t�,_ �� . _ �,« y�9/��. �1 Phone#;802 299-5885 O�cia!use only. Do not wri�e in this areq ta be completed by city or town o�ciaL City or Town: PermitlLicense# Issuing Aut6ority(circle one): ' 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: DATE(MAND�IYYYY� ,a►co o° CERTIFICATE OF LIABILITY INSURANCE oe�=5�=01= 7HIS CER7YFICATE IS 18SUED AS A MATTER OF INFORMAiYON ONLY AND CONFERS NO RIGHTB UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOEB NOT AFFIRMATIVELY OR NEGATIVEIY AMEND, EXTEND �OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE 18SUING INSURER�81, AUTHORIZED � REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE NOLDER. � � IMPORTANT: If the eeRificate holder is an ADDI710NA1 INSURED,the poliey(lea)muct be endorsed. If SUBROGATION IS WANEO,subJed to the terme end conditlons of the policy,certein polieles may requlre en endorsement. A etalement on lhis certiFlcete does not confer rights to the certiFlcate holder In Ileu of such endorsement e. PRODUCER 0726293 1-415-546-9300 NRMEAC AEthuY J. DellBgher & Co. PNONE Ineurance Brokaze of California, Inc., Licenee k0726293 � � NO' MHR One Market P188a, Speei TONBY R 6� ' 9Uit0 300 � INBURERB AFFORDINGCOVEMOE ' NAICA 6an Frencieco, CA 94105 � INBONERA: ��=CH AM6R IN6 CO 16535 INBURE� .� IN6URER B: � BolarCity Cozporation INSURERc: - 3055 C1eaYv10w 47ey . � IN6URERD: � � INBURERE: 6ert [Qeteo . CA 94402 � � . INSURER F: COYERAGES CERTIFICATE NUMBER: 22e1�ass REVISION NUMBER: ' THIS IS TO CERTIFV THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICV PERIOD � INDICA7ED. NO'fWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTNER bOCUMENT WITH RESPECT TO WHICH THIS CERTIFICAT� MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDEU BY THE POLICIES OESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REOUCED BV PAID CLAIMS. � INSR rypEOFINBIIMNCE � $ B POLICYNUMBER PaUpVEFF M�p E%P LIMITS A pENERALL1A91LRY �L0967364403 09/Ol/1 09/01/1Y �CHOCCURitENCE E 1,000�000 O E� 1,000,000 R COMMERCl/�LGENERALLIA9ILITV " PRE 9 E oav E (%NMSMAUF �OCCUR � MEOEXP(Myone rson) E 10,000 X OedLLOCib10: $25,000 pERSONnLBADVINJURY g 1,000,000 GENERALAGGREGATE $ Z.000,000 GENIAOGREGATELIMITFPPLIESPER: , PRO�UCTS�COMP/OPAGG $2.000,000 X POLICY PRO-. LOC - $ A AUTOMOBILE4ABILT' �Q 8293170 0 WMBI,NtlEO51NC+LEUMIT 1,000.000 X �,A�� . BOOILYINJURY(Perperson) S ALLOWNEO SCHEDULED � BO�ILYINJURY(Peraccitlen� $ X HREDAUTOS X AUTOS�EO � PRw�a�dentONM1V1GE s f UM9RELLAllAB OCCUft r FACHOCCURRENCE $ EXCESSLIAB CLAIMS-MAOE AGpftEOFTE S DE� RETENTION � � S A WORKERSCOMPEN6ATION p7C967396703 , p9/O1/1 09/O1/12 X WCSTATU- OTH� ANDEMPLOYERS'W191LI1V ANYPROPRIETORIPARTNEfUE%ECUTNE ��N � E.I.EACHACCIDEM $ 1,000,000 OFFICERIMEMBERE%CLUDEOi N� N�p , (MantlatoryinNX) . E.L.OISEASE-EAEMP�OVE S 1,000�000 Ifyes tlescrl4eundet E.L.DISEHSE-POLICVLIMIT § 1,000,000 �ESCftIPTION OF OPERATIONS balow OESCRIPTION OF OPEMilON3.l LOCATIONS I VEHICLES(AHech ACORU 101,Atlditlonal Remarke Bdietlule,il more space is repulretl) � ' Proof of General Liability, Automobile and Workare Companeation Ineurance. - � CERTIFICATE HOLDER � CANCELLATION � ' SHOULD ANY OF THE ABOVE DESCkIBED POLIqES BE CANCELLED BEFORE ' Yrooi of lnerurance THE EXPIRATION UATE THEREOF, NOTICF WILL BE DFI.WERED IN - . ACCORDANCE WITH THE POLICY PROVISION6. AUTNORIZEO REPftESENTATIVE ,�,� a.,� � 01968-2070 ACORO CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are regletered marks of ACORD jijoean . � . - 22817495 . � Y + � � ' +�'/�, ■ . . �hIP '�! $olarCity. so�ar�ease 3055 Clearview Way, San Mateo, CA 9A402 r (888) SOL-Cf�Y F(650) G38-1029 SOLARCI IY.COM , Homeo�vner Name end Address� Co-Owner Name Uf Any) Installztion Location Contraclor Liccnse � Michael Caggiano 14 Patton Road MA: HIC 168572 14 Ratton Road Salem, MA 01970 Salem, MA 01970 1. INTRODUCTION calendar month, including the Interconnection Date. This SolarLease° (this "Lease") is the agreement We reTer to this period of time as the "Lease Term." between you and SolarCity Corporation (together with The Lease Term begins on the Interconnection Date. its successors and assigns, "SolarCity" or "we"), The Interconnection Date is the date that the System is covering the lease to you of the solar panel system turned on and generating power. SolarCity will notify (the "System") described below. The System will be you by email when your System is ready to be turned installed by SolarCity at the address you listed on. above. This Lease will refer to this address as the "Property" or your "Home." This Lease is up to 3. SYSTEM DESCRIPTION eleven (11) pages long and has up to three (3) Item Exhibits depending on the state where you live. This Lease has disclosures required by the Federal 6.240 kW DC (STC) photovoltaic system Consumer Leasing Act and, where applicable, state law. SolarCity provides you with a Performance Photovoltaic Modules Guaranty and Limited Warranty (the "Limited Inverter(s) II Warranty"). The Limited Warranty is attached as ' Exhibit 2. SolarCity will aiso provide you with a Mounting system System user manual entitled "Solar Operation and Maintenance Guide" (the "Guide"), that contains Monitoring system important operation, maintensnce and service Electric meter number: information. This is a legally binding agreement, so please read everything carefully including all of the Eztras: exhibits. If you do not meet your contract obligations under this Lease, you may lose your rights to the Lease Promotional Discouni System. If you have any questions regarding this Lease, please ask your SolarCity sales consultant. 2. LEASE TERM SolarCity agrees to lease you the System for 20 years (240 full calendar months), plus, if the Interconnection Date is not on the first day of a calendar month, the numberof days left in that partial 'I SolafLcaSc,Jauuary "13� "l_012 . . Copyright Q�20U8-2b12 SolarCily Corporahon.All Rights Rescrved. � . � � J 4. LEASE PAYMENTS; AMOUNTS A. Amounts Due at Lease Signing, Installation and B. Monthly Payments: Building Inspection: The balance of yourtotal Lease Prepayment(See Box �ments Due at Siening: 4A) is due when inspection is complete. There are no Amou�t Due at Lease Signing: $0.00 payments due after this payment. Delivery/Installation Fee: $0.00 Total Due at Lease Signingc $0.00 p,�yments Due at Installation: 50°h of Lease Prepayment: $3,068.79 � Tax: 0. 0 Total Due at installation: $3,068J9 Pavments Due after Insoectian: 50%of Lease Prepayment: $3,068.78 Tax: 0.00 Total Due aRer Inspection: $3,068.78 C. Other Charges: D. Total of Payments: $6,137.57 This is the total amount you will have paid by the end of this Lease. It includes taxes of $0.00. None. E. Purchase Option At End of Lease Term: F. Other Important Terms: You do not have an option to purchase the System at the See Section 2 above for additional infarmation on the end of the Lease Term. Lease Term and also see below for additional information on termination, purchase options, renewal options, maintenance responsibilities, warranties, late and default charges and prohibition on assignment without SolarCity's consent. Payments due upon installation are due immediately priorto commencement of installation. 5. LEASE OBLIGATIONS You agree to: (a) Notices SolarLease � 2 - , � � 20. NOTIC ES i es under this Lease shall be in writin and All not c g 23. NOTICE OF RIGHT TO CANCEL shali be by personal delivery, facsimile transmission, electronic mail, overnight courier, or certified, or YOU MAY CANCEL THIS LEASE AT ANY TIME PRIOR registered mail, return receipt requested, and deemed TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER received upon personal delivery, acknowledgment of THE DATE YOU SIGN THIS LEASE. SEE EXHIBIT 1, receipt of electronic transmission, the promised THE ATTACHED NOTICE OF CANCELLATION FORM, delivery date after deposit with overnight courier, or FOR AN EXPLANATION OF THIS RIGHT. five (5) days after deposit in the mail. Notices shall be sent to the person identified in this Lease at the z4. ADDITIONAL RIGHTS TO CANCEL addresses set forth in this Lease or such other address IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO as either party may specify in writing. Each party shall CANCEL THIS LEASE UNDER SECTIONS 6 AND 23, deem a document faxed or sent via PDF as an original YOU MAY ALSO CANCEL THIS LEASE AS FOLLOWS: document. At any time prior to 5 p.m. of the 14'h calendar day 21. ENTIRE AGREEMENT; CHANGES after the date you sign this Lease. $ 0 This Lease contains the parties' entire agreement FURTHER, IF YOUR 14 DAY CANCELLATION RIGHT regarding the lease of the System. There are no other HAS PASSED, YOU MAY ALSO CANCEL THIS LEASE agreements regarding this Lease, either written or oral. UNDER THE FOLLOWING CIRCUMSTANCES UPON Any change to this Lease must be in writing and PAYMENT OF THE FOLLOWING AMOUNTS: signed by both parties. If any portion of this Lease is If SolarCity determines after the engineering determined to be unenforceable, the remaining site audit oi your Nome that it has , provisions shall be enforced in accordance with their misestimated the System's size, cost or terms or shall be interpreted or re-written so as to annual production by more than ten percent make them entorceable. (10%)(See Section 6(b)) $0 22. PUBLICITY Prior to site audit: $500 SolarCity will not publicly use or display any images of A/ter site audrt, Prior to design: $1,000 the System unless you initial the space below. If you After design, prior to permit: $2,500 initial the space below, you give us permission to take pictures of the System as installed on your Home to After permit, prior to installation: $2,500 show to other customers or display on our website. plus permitting costs omeewnerak�itial . . . . i j' L/ Co-Owner's Name (if any): I have read this Lease and the Exhibits in their entirety and I acknowledge that I have received a complete copy of this Signature: Lease. Date: Owner's Name: Mich} I Caggiano nature: � Da e: � � 2 Solar�ease 10 . , , �.1 � � r � SOL.A9tCl'TY APPR011ED (SolarCitVS'n . •� � � � � � � � e LYNDON RIVE,CEO SolarLease �� Date: 3-0' �� � � � . solar4�ase 11 , , ABBREVIATIONS ELECTRICAL NOTES INDEX LEGEND LICENSE A AMPERE 1• WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET O (E) UTILITY METER (6) AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS — MP1 INVERiER W/ INTEGRATED DC DISCO & CONC CONCRETE OF THE HAZARDS PER ART. 690.17. PV4 UPLIFT CALCULATIONS �"" WARNING LABELS. (3),(4),(5),(6) � COMBINER BOX 2• EACH UNGROUNDED CONDUCTOR OF THE PVS SINGLE LINE � DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENiIFIED PV6 ELECTRICAL CALCULAiIONS BY PHASE AND SYSTEM PER ART. 210.5. PV7 CUTSHEETS p DC DISCONNECT (4),(5) DC DIRECT CURRENT 3. A NATIONALLY—RECOGNIZED 7ESTING PV8 CUTSHEETS EGC EQUIPMENT GROUNDING CONDUCTOR LABORATORY SHALL LIST ALL EQUIPMENT IN PV9 CUTSHEETS A� (E) EXISTING COMPLIANCE WITH ART. 110.3. � AC DISCONNECT (3),(4),(5),(6) JURISDICTION NOTES EMT ELECTRICAL METALLIC TUBING 4. CIRCUITS OVER 250V TO GROUND SHAIL G SOLAR GUARD METER � JUNCTION BOX — ALL W�RK SHALL GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) O GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER C❑MPLY WITH THE GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES O DC COMBINER BOX (7),(9) MASSACHUSETTS STATE HD6 HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC BUILDING C�DE, I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). � 7}{�S SYSTEM IS GRID—INTERTIED VIA A o DISTRIBUTION PANEL i Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WIlH STRAIN UL—LISTED POWER—CONDITIONING INVERTER. � � �'�2� — ALL ELECTRICAL W❑RK i INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS SHALL C❑MPLY WITH THE 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY " LOAD CENTER (3),(4),(5),(6) 2011 NEC, kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE GROUNDED. kW KILOWATT UL—LISTED LOCATION PROVIDED BY THE 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED O DEDICATED PV SYSTEM MEiER LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 5. ALL ELECTRICAL WORK SHALL COMPLY WITH THE MIN MINIMUM HARDWARE. � CONDUIT RUN ON EXTERIOR (N) NEW 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, 2011 NATIONAL ELECTRIC CODE. --- CONDUIT RUN ON INTERIOR NEC NATIONAL ELECTRIC CODE RAIL, BOXES, ETC. SHALL BE 6ROUNDED USING 6. WORK TO BE DONE TO THE 8TH EDITION OF MA — GATE � STATE BUILDING CODE. --- �NTERIOR EQUIPMENT NIC NOT IN CONiRACT UL LISTED LAY—IN LUGS LISTED FOR THE 7. UL 1703 — SOLAR MODULES NTS NOT TO SCALE PURPOSE. POSTS SHALL BE MADE g. UL 1741 — INVERTERS OC ON CENTER ELECTRICALLY CONTINUOUS WITH ATTACHED p PANEL BOARD RAIL , p� PROPERTY LINES 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PV PHOTOVOLTAIC BONDED WITN EQUIPMENT GROUND CONDUCTORS PVC POLYVINYL CHLORIDE AND GROUNDED AT THE MAIN ELECTRIC PANEL. SCH SCHEDULE 10 SHALLCBERSOIZEDIACCORDINGO�TO ARTDUCTOR VICINITY MAP I', SS STAINLESS STEEL 250.166(B) & 690.47. p r� .; e1� �g .� �, SSD SEE SiRUCTURAL DRAWINGS r k + �^^�<`Ao °� p STC STANDARD TESTING CONDITIONS + j'� 05�s , �'� ��'�a `� Sy,�-� SOLAR WATER HEATER � TYP TYPICAL + �QYB ~ � � UON UNLESS OTHERWISE NOTED ' � A¢ ,/ z o�� � e� V $ P¢ze�� Q UPS UNINTERRUPT18LE POWER SUPPLY I' � $ a s s; R y VOLT �J �e� � ' . Vmp VOLTAGE AT MAX POWER a M=�aa � ���' ����'e� r"� Voc VOLTAGE AT OPEN CIRCUIT fr • �Ra Mnak � W WATT ,/ s.� �.�,�' Q � f.�" � 3R NEMA 3R, RAINTIGHT /'�„d R° �� ' .� ��� �,r o s�a,�� � } • ' + . � . � �`•O' ��'� 6 �r Rlckmzn � �!. '� _ PBB t ,� F' a - MOlfa�rRd 'c c 4'�. l..-._.. � �; � � s, r 'a � e a `;,y REV BY DATE COMMENTS � �S /'� a Q v�atl q cranl @tl " � �dy��...� REV• � ����r 3 a f , s.o � , � 11�, �y/ a ,�_ `- `g � "�.� e° J � . . - p., 3tr 1. �Qd � ���c,�n�.-� � ��p, 1o�v F' .,:��ue� �f � .,: ��° PiUman� 9� . � � � a' c CONFlDFN7IRL — 7HE INFq2NA710N HERON Jp6 NUYBER J B-019 0 6 2 O O P�MISE OWNER AHd Salem DESCPoPTICN: p[y�ry; '��,�, CAGGIANO, MICHAEL CAGGIANO RESIDENCE vwoNc ����� SolarCity CONTAINED SHALL N0T BE USED FOR iHE �. BENEf1T OF PNYONE EXCEPT SOIARCIN INC., 4AIMEi: MODUIES: NOR SHALL IT BE DISCLOSm IN WHOLE IX2 IN RESI 26 YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Ar�ay ��� PMT TO O7HERS WT9DE THE REqPIENTS SALEM, MA 01970 ° ORCANIZA710N, E%CEPT IN CIXJNECTION N17H ��T uµA�� YWNIING SYS7EY: 7HE SALE AND USE OF 1HE RESPEC7IVE ECOFASTEN L—FOOT 2—LAG & SC RAIL � 3oss aea�;�„waY SOLARCIN EWIPl1ENT, VA7HWT THE VRtITTEN P�N�E: SNEET; REV: DATE: San Ma[m,CA99902 PERMISSION OF SOLARqTY INC. PA�ASEE �N 1 SMA SUNNY BOY 6000—US 978740108� 3 2� 2��2 T:(650)638-1028 I F:(650)638-1029 (� # COVER SHEET PV 1 / / (888)-SOL{Ryp65d989) I ���artiry.mm — Roof Mounted SEEPV3 DETAILS A,B,C MPl PITCH: 22 ARRAY PITCH:22 AZIMUTH: 175 ARRAY AZIMUTH: 175 MATERIAL: Comp Shingle Roof STORY: 2 Front Of House LEGEND Q (E) UTILITY METER (6) INVERTER W/ INTEGRATED DC DISCO & Inv �°° WARNING LABELS. (3),(4),(5),(6) AC ; � DC DISCONNECT (4),(5) , a , ,, � p AC DISCONNECT (3),(4),(5),(6) M � � � , � —-- Q JUNCTION BOX � DC COMBINER BOX (7),(9) Q DISTRIBUTION PANEI (1),(2) �c LOAD CENTER (3),(4),(5),(6) B PV3 O DEDICATED PV SYSTEM METER � CONDUIT RUN ON EXTERIOR • --- CONDUIT RUN ON INTERIOR M — GATE --- INTERIOR EQUIPMENT A PV3 SITE PLAN N Scale: 1/8" = 1' W E 0 1' 8' 16' S J B-019 0 6 2 0 o FRE1115E OYMEIt AHJ Salem DESCPoP710N: pEg�: ``' '' CONFlDENTIRL- THE INFq2NA710N HER�N �oe�uwaoc CAGGIANO MICHAEL VWONG �, � CONTAINED SHALL NOT BE USED fOR 7HE , CAGGIANO RESIDENCE ��",SolarCity BDIEFlT OF ANYONE EXCEPT SOLARCITY INC., ypq�T: MOWIES NOR SHALL IT BE DISCLOSm IN WHOLE OR IN RESI 2s YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array ►� PPRT TO O7HERS WTSIDE THE REqPIENYS SALEM, MA 01970 ° ORGANIZA710N, E%CEPT IN CONNEC710N N17H ���T W�A�' YWN7ING SYS1Fll r�e sa� uau use ov n+e eesacen� ECOFASTEN L—FOOT 2—LAG & SC RAIL 3055 Clearnew Way SOLARCITY EWIPIAENT. N17HWT THE WRITTEN PACE NAIIE: 9{�T: FEY: UAIE: San Mateo,U194402 PERA9SSION OF SOLARqtt INC. PA1I�ENT ME '"� '�: g787401 080 T:(650)638-1028 I F:(650)638-1029 LEASE �1 SMA � SUNNY BOY 6000—US SITE PLAN PV `2 3�2��20�2 (888)-SOL{ITY(]652489) I w�.:o�arciry.�om 4' BETWEEN FOO7INGS STAGGERED X� � —4� T� (E) 2x10 RAFTERS � i6" SPACING B FRONT VIEW OF MOUNTING PLANE Scale: 1/2"=1'-0" � . (E) 2x10 RAFTER � 16" O.C. C PV3 NOTE: RAIL TO BE PLACED IN THE UPHILL DIRECTION SOLAR PANEL INSTALLATION ORDER ATTACHED WITH MODULE LOCATE RAFTER, MARK HOLE REDGEXBOARD CLAMPS, �"—i6 BOLTS, (1) LOCATION, AND DRILL PILOT ° AND �" NUT (5) HOLES USING 1/8" BIT. 1x8 r 22' SOLARCITY SOLAR RAIL _ — _ _ �4) (z) PLACE THE QUIKF00T. & BOLT — — — LEVELING FOOT �3) (E) 2x8 CEILING �3� INSTALL POLYURETHANE ��, 12�_$� JOIST � 16" O.C. (E) COMP. SHINGLE SEALANT AND SCREWS. �E� �BW (4) INSTALL FLASHING. ECOFASTEN FLASHING RAFTER: 2x10 � U �5� INSTALL L—FOOT WITH SEALING SUPPORT: ix8 (E) ROOF DECKING WASHER. MAX SPAN: 12'-8" Tf21ANGLE FASTENER #14 (2) c>> SIDE VIEW OF MP1 WOOD SCREW (3" EMBED, MIN) � (E) RAFTER /'1 C STANDOFF SCALE: °�—� Scale: 1 1/2" = 1' J B-019 0 6 2 0 0 �E°�°�� �= Sa�� OESCPoP710N: DE9GN: �� � CONFlDEN7IAL — 1HE WFORNA710N HERQN JOB NUYBEk VWONG `�„�' e� } CONTAWED SHALL NOT BE USED FOR 1HE CAGGIANO, MICHAEL CAGGIANO RESIDENCE I��,SOIA�I ` o BQJEFlT OF ANYONE E%CEPT SOLARCI7Y INC., YpPo(ET; NOq11ES I NIXt 91N.L IT BE DISCLOSEO IN NHOLE OR IN RESI 2s YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array � PART TO O7HER5 W79DE THE REqPIFNT'S p��CT YANACER �a,r,nN�5n�,,: SALEM, MA 01970 ORGANIZA710N, EXCEPT IN CONNEC110N W1TH 3055 CleaMe.�way iHE SALE AND USE OF THE RESPECIIVE ECOfASTEN L—FOOT 2—LAG & SC RAIL sa�wM�,cn9amz SOLARqTY EW�PIIENT, YAIHWT iHE NRITTEN PA.��T�E w,� �, . PAGE NAYE: SHEET: REV: DAIE: r:(sso)638-1028 I F:(65o)6se-ioz9 PvxMrssion oF so�aean iwc. LEASE (�� SMA # SUNNY BOY 6000—US 9787401080 STRUCTURAL VIEWS — MP1 PV 3 3/2i/2oi2 (888)-SOL{Ry(7654489) I �+�'so�arciry.mm UPLIFT CALCULATIONS INPUT VARIABLES C.4LCULATIONS AND UALUES Requi�ed �ariables Design wind pressures based upon: Mean Roof Height: Z5 ASCE 7-05 Chapter 6 Wind Loading Exposure Category: � Equation 6.5.13.3: Component and Cladding Elements Basic wind speed (or city in the future): 100 W�nd pressure P=qh*Cn*G Importance factor(1 for residential): 1 6.5.10: Velocitv pressure qh =0.00256'Kz'Kzt'Kd`V^2`I Roof shape: pitched From Table 6-3: Roof Angle(degrees): 22 Kz=0.95 Roof zone: 3 From Fipure 6-4: Contiguous sq. feet of array: 105 Kzt=1.00 Least width of the building: 31 . Obstruded wind flovJ� TRUE From Table 6-4: Kd =0.85 Local Topog�aphical Features (choose "standaN"orreferto pictures nght, and below) From figure 6-1: V= 100 Type of hill: none Hill height(h)(ft): From table 6-1: Slope of hill (degrees): I = 1 Horizontal distance from hilltop to house(x): From VelociN Pressure Eauation . Height from bottom of hill to mean.roof height(z): qh=20.63 Design Wind P�essure From Figure 6-196 P(Ibs. per sq.N.)=qh'Cn•G Cn (uplift)_-1.41 Pd (downforce pressure)= g,77 Cn(down)=0.50 � Pu(uplift pressure)= 24J8 From 6.5.8.1 G=0.85 Max TributaryArea Feet Inches Individual Rows in Portrait X(E-W distance between standoffs)= 4 0 Yingli YL235 P-29b Y(N-S distance between standoffs)= 2 6 Amax(sq.ft.)=0.5*L'X Staggered Penetrations= Yes L(length of panel in ft. perpendicular to reil) 5.41 Module Rail Max. Span/Cantilever(in)= 48 19 X = 4.00 v= z.so Max UpliR Force on a Sinqle Standoff �- N�A Pmaz(Ibs.)=Amax`Pu Amax= 10.83 268 Dead Load Calculations Factor of safety =FI•�'NI/Pmax DL(Ibs/sq.ft.)_(Mm+Mh)/(L"Mn 1/4 x 4 in. = Lag size and length 375 =Capacdy(Ibs)of 1 lag (NDS) L(length of modules) 5.41 Z = NI(number of lags per standof� W(width of modules) 3,Z5 z.80 = Factor of safety � Mm (weight of modules)43.65 Point Load Calculations Mh (weight of hardware per module)= 4.15 PL(Ibs)=Amax*DL DL= 2.72 29 J B-019 06 2 00 PREYISE OMNFR �� ��em o�Pn�: ��,, � CONFlDEN7IAL - 7HE INFIXtMA71IXJ HERFIN JOB NUYBER: `���I� fANTAINED SHALL NOT BE USED FOR 1HE CAGGIANO, MICHAEL CAGGIANO RESIDENCE VWONG . SOI��I ` NORESHrll11TN9ENDI5CLOSEO ISNIRIWE ORCIN ��ET: y��S 14 PATTON ROAD �I�� GART TO O7HER5 WTSIDE 1HE REqPIENYS RESI 26 YINGLI YL240P-29b 6.24 KW PV Array a ORGMlIZA710N, EXCEPT IN CONNECTION KttH ���T Y�A� �WN¶N�Sn,�: SALEM, MA 01970 7HE SALE RND USE OF THE RESPEC7IVE ECOFASTEN L—FOOT 2—LAG & SC RAIL 3055 CleaMewWay SOLARCITY EWIPMENT, N17HWT iHE WRITIEN PAGE NANE: $HEET; REV: DAIE: 5an Mateo,cA944o2 PERMISSION OF SOLARCITY INC. PALEASEE� M��"SMA # SUNNY BOY 6000—US 9787401080 UPLIFT CALCULATIONS PV 4 3/2i/2o�2 �888)6�OlLRYp654q89)���650�3�'a02� � OUND SPE MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #6 EGC/GEC TO (N) GROUND (E) 200A MAIN SERVICE PAN0. Inv 1: DC Negatively Grounded INV 1 —����A!�NNY B Y 6000-US �ggp,, — 6 11NqJ /YL240P-2 ROD AT PANEL WITH IRREVERSIBLE CRIMP (E) 200�2P MAIN CIRCUIT BREAKER Inv�`-2011� 6000W, 277j�ao/2�V, 96.OR/9S51G/95.5% Voc: 37.5Nodule (-2011 : 240W, 215.9W PTG H4, 5011M,Black Frame Panel Number.MURRAY LC230PC Vpmax:29.5 Meter Number.gg 652 621 iMODULE CURRENT RA71NG5 ARE SHOWN AS Isc AND Imp IN 1HE DC STRINGS IDEN7IFlER OF 7HE SINGLE UNE DIAGRAM. MAIN SERVICE PANEL SOLARGUARD Inverter 1 (E) WIRING CUTLER—HAMMER ME7ER 200A/2P Disconnect 3 SMA SUNNY BOY 6000—US (E) LOnoS g C � z�� AMPHENOL m� �+ Y Branch Connector i r� � GFP/GFCI �{ 35A/2P � eca DC+ ❑ r p�+ 2 SMrg(s)Of 13 On MP 1 I ___' GN� _ ___ 6ND _ _____________—___________ ___ __ � A � GEC � A I N L___ �C_—_—____---___--___________ _______�___ �� I B � GN� __ EGC EGC __—_—___----________________ ___________ ____________________J I I I N � I I EGGGEC � o — — z z � _ '___l i ___ GEC __� 70 120/240v � SINGLE PHASE � . i U7ILITY SERVICE i i i i i _� OI ���W71.ER-HANMQt /BR235 PV BAq(FEID BREAKER B (i)W TI.ER-HANMQt /DG222URB A (1)AAIPHFNOL I H4ri � Breaker 35A/2P„ 2 �paces DiscanneHct 60A,s240Va Nm-Fuemla, NFAfA JR AC Y Branch C/onnecta: H4, Nale DC — 1)(.Yaund�toA; 5/8 x 8, Capper —���Wro�und/N�eu�tr�al Kit 6�000. General Duty(DG) —����Y Brundai Conn�tor; H4, Female C (1)SOLARCITY M SG ME7FR —(I)AWG /10, 7HNN-2, Bladc (SH) Mmitain 'E u' enk ZPB/Z40 2-wire —(i)xa�,w�a$�"aa —(i)nwc t�o, nixr�-a R�a (sn) EndosurC NDAA 3R —�2�uu�/1�4 AYM.,�Some side,Pln�sulated —�I)AMIG /10, 7HNN-2, Aean (Sft) T(1)AN'G /8, 7HNN-2, Bladc 2)AWC/10, USE-2/RHW-2, Black Voc =q87.5 VDC Ix =D.3 ADC (4)AWG /10, USE-2/RHW-2, Blak Voc =487.5 VDC Isc =8.65 ADC OIq�(1)pN'G /8, 1HNT!-2, Red � O�(I)AWG/10, Salid Bare Cappa EGC Vmp =383.5 VDC Imp=16.28 ADC O�(I)AWC /10. Sdid Bme Capper EGC Vmp =383.5 VDC Imp=8.14 ADC �L(1)AWG/10. 7HNN-$ Nfiite NEUIRAL Vmp =240VAC ImP=25 AAC . . . . ��(I)Conduit,KiL.3/4',EYT.. . . .. . .. . .. ... . .. . . .. . . .. .. .. . .... . .. �J .... . ... .. .. . ... . . .. . . .. . . .. . . .. . . .. . ... . . . . . . .... . -f!)awc.ia..n�wr+-z.c.�.Ecc�c�c. .-(t).co�a�x.K�4.3/<'�7.. . ... .. . J B-019 0 6 2 0 0 �u���� µ� �lem o�Pn�: ��,: �► , CONFlDENTIAL - THE MFORNRTION HER�N JOB NIIY�k VWONG `�„�' q } CONTAINED SHALL NOT BE USED FOR iHE CAGGIANO, MICHAEL CAGGIANO RESIDENCE ��,SOIG�I ` o BENEf1T OF ANYONE EXCEP7 SOLARCITY INC., MMIQT: YOWIES I NIXt SNALL IT BE DISCIOSED IN NHOLE OR �N RESI 26 YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array PART TO OTHERS WT9DE THE REqPIENTS ��T M�� uwxnNc srs�u: SALEM, MA 01970 ORGANIZR710N, EXCEPT IN CONNECIIpI N17H THE SALE RND USE OF 7HE RESPEC7IVE ECOFASTEN L—FOOT 2—LAG & SC RAIL 3055 Clearview Way SOLARCITY EWIPNENT, W11HWT 7HE MRITTEN PAGE NAYL $HEET: REV: DAIE: 5an mateo,CA 994az PERMISSION OF SOLARq7Y INC. PALEASEE �N(1) SMA # SUNNY BOY 6000—US 9787401080 SINGLE LINE 3 21 2012 T:(650)636-1028 I ;�II650)638-3029 P V 5 / / (888)-SOL{[ry(765-2489 www.solamry.com 1. Conductor Sizing per Art 690.8(B1f11 ELECTRICAL CALCULATIONS a. Conductor must have 30 deg. C ampacity >= 125� of continuous current per Art 215.2(A)(1). Module: �26�1'ingli YL240P-29b-i�- 215.9 Inv Pwr W PTC StrLen Volfaqe Drop Calculations Version 5_8.16 b. Conductor must have (ofter corrections tor conditions OT U50� >= Imerterl: 11SMASB-6000US(240� 95.5% 6;000 5,36 11 Vdrop= (Imp) ` (2"Length)'(Resislance) / (Vmp) continuous wrrent per Table 310.15(B)(i6). Moduie: � � Imp(A) Mau. Length(ft) Wire Imerter 2: �"'�j���`String: 8.14 50 C AWG 10 at Max Aee Hi: 82 deg F Module: ` + Vdrop= (8.14 A " 100 ft "0.00124 Ohms) / 355 V= 0.25% c. Evaluate conductor temperature at terminations per 110.14�C�. In�erter 3: �'T Branch: 16.28 40 C AWG 10 at Max A�e Hi: 82 deg F Ampacity of wire derated for conditions of termination must be �= Module: 4 _�,p g��, � Vdrop= (1628A • aoe •0.00�2a onms> i 355V= 0.45% continuous current*1.25. All string terminotions are roted Ot 90' C. Imerter 4: _ _ _� ] __�r�f� Total wltage drop in DC conductors= 0.74% ------------------------------------------ . � � Inverter. 25.00 10 C AWG 10 at 240V 2. OCP Sizinqper Art 690.8(B)(1) Total: 26 modules Total Inv Pwr 6,000 �361 PTC Vdrop= (25.00 A ` 20 ft '0.00120 Ohms) / 240 V 025% a. RoUnd Up to next size per Art 240.4(B) Photovolfaic Module Electriwl Soecifications: Total STC � 6,240 Combined 25.00 0 E AWG 06 at 240V Voc= � ���37.5 V deg F deg C Vdrop= (25.00 A ' 0 fl '0.00049 Ohms) / 240 V 0.00% Vm - 29.5 V Record Low Tem : 9 22.778 Total wltage drop in AC conductors= 0.25% 3. CondUClof Sizing per Art 690.8(61(i l Isc P � 8.65 A Max A�erage Hi Temp: 82 2T.7778 Total wltage drop in AC aM DC conductors = 0.99% a. Conductor must have 30 deg. C ampacity >= 125% of continuous Imp= 8.1 n current per Art 215.2(A)(1). Twc= -o:a3ae videy c Tisc= �5A9 mA/deg C b. CondUClof mUst haVe �offef CoffeCfions fOf Condili0ns of Use� >= SVing Tvpe A and 2 Combined Strinas Tvpe A Voc Correction Method: Manuf Twc data Branch Circuit Tvpe A 1-way wire length: 40�fl SMA SB-6000US(240V) � �- � 2 strings per branch 1 COntinuoUS CllffBflt Pef TObIB 310.15�6��16�. 13�Yingli YL240P-29b Imeder Min Vdc Input: 25� Vdc M 13 modules per series string Voc= 487.5 V Min Vmp at Max Temp: � �355 Vdc Voc= 487.5 V c. Evoluote COfIdUCIOf temperoture at terminations per Art 110.14(C). vmP= 3e3.5 v Max Voc at Min Temp: 574 Vdc Vmp= 383.5 V Ampacity of wire derated for conditions of termination must be >= isc= a.s5 n Imerler Max Vdc Input: 600 Vdc Isc= 17.3 A continuous current�1.25. All bronch terminotions ore roted ot 75' C Imp= 8.14 A Max String Size: _ 13 Imp= 1628 A min. Icont= 10.81 A AA 690.8(A)(1) 1-wa wire length: � 50'ft Icont= _ 21.63 A Art 690.8(A)(1) __________________________________________ 1.a CorWuctoc C AWG 10 USE-2/RMN-2 at 90 deg C: Table 310.15(B)(16) 2.a CorMuctor 1:C AWG 10 7}iWN-2/USE-2 at 90 deg Q Table 310.15(B)(16) 4. OCP Sizina Conducror 1: a. Round up to next size per Art 240.4(B) icont'1.25=(Amps) �3s2 Iconl"1.25=(Amps) 2zo3 ------- ------------------- 30 deg C ampacity= 40 30 deg C ampacity= 40 ' 5. Conductor Sizingper Art 690.8(B)(1) 1.b Icont= (Amps) 10.87 2.b Icont=(Amps) 27.63 a. Conductor must hove 30 deg. C ompocity >= 1257 of continuous start ampaciry ao start ampaciry a cu��ent pe� A�t 215.2(A��1�. Temperature derate(%=F) 0.76 Temp. derate(%=F) 0.76 ConduR fill derate(%_#) 1 Cndt. fill derate(%_#) 1 b. Conductor must hove (ofter corrections for conditions of use) >= oerated amPaciry 30.40 Derated ampacity 30.4 Tertn 1 Term 2 continuous current per Toble 310.15(B)(16). t.c Icon�"1.25=(Amps) 13.52 Temptable 75 egC 75degC Ampacity 40 2.c Iconl'1.25= (Amps) 27.03 27.03 c. Evaluote conductor temperoture ot terminotions per Art 110.14(C). Ampacity __ 35 _ 35 Ampacity of wire derated for conditions of termination must be >= t.d Icont"1.25=(Amps) 19.52 2.d E�c C AWG 10 C AWG 10 Art.250.122 continuous currentx1.25. All inverter output terminations are rated at OCP size= 75" oca size= 30 75' C. ___________________________________________ InverterTVPe A OutPut 6. OCP SiZina SMA.SBEOOOUS (240V) 1-way wire length: 10'ft Icont= 25.00 A Art 690.8(A)(t) o. Round up to next size per Art 240.4(B) 3.a icont'1.25=(Amps) 3L25�A nrt sso.s(s)(�) OCP size= '36 A Art. 240.6(A) 7. Conductor Sizing per Art 690.8(B)(il s.n conductor C A�NG 10 THWfw2 at 90 deg C:Table 310.15(B)(16) a. Conductor must have 30 deg. C ampacity >= 125% of continuous icont' 1.25= (Amps) 31.25 current per Art 215.2(A)(t). 3o de9 c ampacit = ao 3.c Icont=(Amps) [ . 25.00 Starl ampacity � 40 . . . _ _ b. Conductor must have (ofter corrections for conditions of use) >= remPerature derate�°i=q o.si continuous current per Toble 310.15(B)(76). Conduit flu derete(°io=#� � Derated ampacit 36.4 c. Evaluate conductor temperature at terminations per Art 710.14(C). a.d icont'1.25=(Amps) _ 31.25 Ampocity of wire deroted for conditions of terminotion must be >= Ampacity _�35 continuous currenf'�1.25. All inverter output terminations are roted al 3.e EGC/GEC = DAWG 08 Art. 690.47(C)(3),250.166(B) 75' C min. CONFlDEN7IRL- 7HE INFORNATION HERON ,q8 NUYCER J B-019 06 2 O O ���OMNEA: R44! Salem OESCPoPPON: OE9CN: �� � CONTAINED SHALL NOT BE USED fOR 1HE CAGGIANO, MICHAEL CAGGIANO RESIDENCE VwONG "��`' BENEFlT OF ANYONE EXCEPT SOLARCI7Y INC., NARI�L N�DUlES: ',1�SolarCity NIXt SHALL IT BE DISCLOSm IN VMOLE Oft IN RESI 2s YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array PART 70 O7HER5 WT9DE 7HE RECIPIENYS ��T��A�R uwNnr�c mhu: SALEM, M A 01970 ORGANIZA710N, EXCEPT IN CONNECTION 1NTH 3055 Clearnew Way THE SALE AND USE OF 7HE RESPECTIVE ECOFASTEN L-FOOT 2-LAG & SC RAIL SOLARCITY EWIPNENT. WITHWT THE WRIT7EN PAVLENT IYPE: IN7EF7ER: PAGE NANE yIEET: REN. DAIE: San Mateo,CA 94402 v�Missiorr o� so�axan iNc. LEASE (1) SMA � SUNNY BOY 6000-US 9787401080 ELECTRICAL CALCULATIONS PV 6 3/2i/2o�2 (Bg8)SOICIiY(]65Z2989)��650�o-a°�� �� � 2�� YL240P-29b � ( �('„� E Z�O SERIES Y1235R29b YIN "IG{,_,��W.AR � YL230P-296 �' /1\ �f SERIES YL225P-296 3�ELECTRICAL PERFORMANCE �"'e.`�°.w"� � . GENERAL CHARACTERISTICS Med 1 nanie � YGENO YGE1I5 YGEtlO YGE3]5 O�manYem�lM1'//1� N,96n(16'Am�/3398i�NGOnmj/ . __ —.. — __ _. ' _." ._ — .. _ ____ __ Mad lelype VLd10V89b VLiJSPdVb rit30P396 Y1225P33h . IW..I50�...) COMPANY Po output P,w W p�p US 330 3]5 Wei9ht -- — ad01dsp9.5kg� r � u�.p� i ,� - - - � �nv..� x .i-a � '- ' . .. Yingli Green Energy(NYSE:YGE)is one ofthe world's largestfully meame<mae� � o- x ��.> >u i..i in.e verticallyintegratedPVmanutacturers.Withover2GWofmodules °h=e•.�� � v..,� v � ns � n.s � �zvs zvs � PACKAGING SPEQFICATIONS •. , ^� . ..��� ' C ntnFnua . T_ � �Amm... B BA6 ).9) ).80 ).El Numberelmedule�perpallm N � installed globally,we are a leading solar energy company built upon — — -- -- __ __,_ ._ __ provenproductreliabilityandsus[ainableperformance. Founded �YOK�nuhvWuge �� V« V l).5 3].0 3].0 16.5 _ ry�pnalpa0a¢pr53'mmim.� se� snw-e.sunam.em ir n a.es es� e.ao s.za in7998,YingliGreenEnergyservescustomersthroughourU.5. s*u,caownx���.�u�,zrc�,� -- � �� - - � � �� "M'^e'^e°^�e�n�,iuwmr n�mn,ao,,.�uiasi�u,so�mmv yeiuu[.PM ISy yxay..n ayad=g�o EN 60.GE-1 )n UlSpmrN subsidiary,Yingli Americas,co-headquartered in New Vork and '"�^wmP��a�o^��^b�a� �u��^�. San Francisco.We are the first renewable energy company and the eo.�,.sm T _ _ vai imwz:ugi. � first Chinese company to sponsor the RFA WoAd Cup' � � � � � � � ' Po.o.o�npm v�.,. w '� i��� no.� iszo +m.e Units:inchlmm) ; _ . .. _. . — __— __ ..___ _. . _ _ _ . _.'___ �. ven.y..�v... v.,,, v ¢a.e ze e ze e 36-0 i PERFORMANCE u,,;e„�rd_.- — M„ a - ese ewz ezv a.ie �9�j9�°� -Industry leading in-house manu(acturing of polysilicon,ingots, oo.�<��.,,n.auy. v_ v � s�.z ao.e 3J.8 13.3 3?P�Oap� vm{sm wafers,cells and modules ensures tight convol of our material snon-�;.<��e..,.�.m � i. n oni e.oz e.ei e.n and production quality. uocr��a�<:�W�q.<.�re.a�.e„a.,.e.,.�mowi�+:,de.rc�,mc,,,s.�,��a,x•rc.���.»mx,tta � ' -High performance,multicrystalline solar cells deliver a module senes eHiCiencyofuptot4J%,reducinginstallaUoncostsandmaximizing 7HERMALCHARACTERISTICS ^ � thekWhoutputperunitarea. �e�..ieo«.ei��.nmma„m�. wocr c �•��� I I -Powertoleranceoi+/-3%minimizesPVsystemmismatchlosses. T.mw�.<�,.�oMn.��erv... v *rc a.as LI— g Tampaneum eo.lfkimt a(Vv 6.� '/�'� � -0.l) x-aO.Ise�Ib1�• ^ QUALITY & RELIABIUTY r.mp..,.,,..<o.m<i.�„rk +.K --- o.a� ---- a g a -Robust,cormsion resistant aluminum frame independendy tested towith5tandwindandsnowloadsofupt850psiand113psi, ppERATING CONDITIONS ^"�^^�'�'^� respectively,ensuring a stable mechanical life. ^-o.2sa.^�„s Mai.ayvtam rNtago �Vu �� � -Manufacturing facility cerfified to 1509001 Quali[y Managemeni �,so,��p �Ma �� ,. . System standards. -- - � -- - -�- � - ---. . . __. . - _ °'au�em� <. q a �I �� Opo �r�geemp.aaran�ge <o �va•F4-W�osvG � 0-°4'�5��"� — -Modulepackagingoptimizedtoprotectproductduring Maas�etl[baClmntlog�vwwendrM) 113pz1�$CWPa� s � � < transportation and minimize on-site waste. m...n.n�m,a.�k i..g.,..��m S�psf R400 Pa� ---- WARRANT�E.S W�htonefmpaa In�25mm)a�flmp�(13Mil �'Oq��p ```• -EMensive Sryear limited produc[warranty and a 25-year limited power T . � � , warranty. CONSTRUCTION MATERIAlS !' s ,; -LimitedpowerwartanTy* =90%oftheminimumratedpoweroutput F�°"e�.�m,w.�.��urE�a,.y �a..:,��gt,aimm¢o�at3.smm ', s sE�N°-" ; �, for 10 years,80%of tke minimum raied power output for 25 years. 4^��tw.�+�rim.+..�V.rcadim�uwd.�,� aa�a yscm��R.,n�,y�aic��i \ (� P 15L mm a i 56 mm{3E].�un� 'Inw IiarcewMiourwarran rermsandmMficionz. E� ^w �Y PwHn�ima�aRa) E�hyi�mNrMuanmlEVN �� : fnmeU�am.�aVicelM NumMwnaBaYlarodaeduTerorb6d._�. . \•� ��et��% ` d ClUA41FICAT10N5 & CER7IFICATE5 ,�n��so.w.o�.��.s..., ��� f� Wa.��gReadiAemsidbuo�a�wUurMmuainnsem'very � UL1703andULCV03,UlFireSaferyClassC,CEC:FSEC,15090012008, �,yie��p,,,,piyy,,,y,/mns�ed'ame�ed pvwuel<�zamptoommlliaawGl6zaa'n(e.zmmi ���orehandlvg,msWlvg,andope�awgYny6modulez. .��__.� ._..... ..�. �50�Q���:Z���BS�5f�15�0��:2�7.51��� VluBcaniw0.0 MnPhCMIlH<IIPtH fman+�xN'w/%Pa/O�ndien ALq+iN C UL U8 _ _ O�.Panners Iqa�g� �I ..wrfg� � •_ 'Thespecificat�a�uinthisdacasheetaenotyuaim�eedaMarewHjeciwchar�gevlhartprwrnonce. � aon"ro :� --_. Yingli Green Energy Americas,Inc. �� � - V� ' � info�yingliamericas.com � �� \ Te1:+11888I686-8820 ��N�p�� ..� ���'� ---� , YINGUSOLAR.COM � NYSE:YGE ,1� YIN(�iLISOLAR.C�M I Yny�iAme�icas __�` � � - _ �-`�-�� gYngliWnenEm�g/HOIJgCUL11 � rsEzmsn,„�€rizmio�wi ' i CONfIDENTIAL - 7HE INFORNATION HERON Jp9 NUYBER J B-019 0 6 2 O O ����OMNER: AHJ Salem DESCltlP710N: OE9GN: -�� �' CONTAINED SHALL NDT BE USED FOR 7HE CAGGIANO, MICHAEL CAGGIANO RESIDENCE VwoNG ���� SOI��I ` BENEFlT OF ANYONE E%CEPT SOLARCITY INC., ypp�F. YODUIES: NOR SHPLL IT BE DISCLOSm IN NHOLE OR �N RESI 2s YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array PRRT TO O1HER5 W751DE 7HE REqPIENYS SALEM, MA 01970 � ORCANIZAlION, EXCEPT IN CONNECTION N17H ���T M�A� MWN7ING SK1EM: 7FIE SALE FHD USE Of THE RESPECTIYE ECOFASTEN L-FOOT 2-LAG & SC RAIL 3055 Clearview Way SOLARCIN EWIPNENT, Ni7HWT 7HE NRITIEN PAtLENT TPE: IN 7Qt: PAGE NAME: 91EEi: REV: DAIE San Matm,Cq 99902 PERMI$$ION OF SOLARqTY INC. � SMA SUNNY BOY 6000-US 9787401080 CUTSHEETS PV 7 3/2� 'ZQ�2 T��650)638d028 I F:(650)638-1029 LEASE ( # / (888)-SOL{Ry(765-2989) I �.solarcity.com � re�hn��elemn sunnreorwaaus sannreoreooaus s�nnreorlooaus svnnrsey6000+ls aaev�c vov�c mv.�t amv�c zaovnc �nv�c �mvnc vov�c mvnc vov,�c mvuc SUNNY BOY 5000-US / 6000-US / 7000-US / 8000-US ��P������ Maw.�ecommmded PV powtt(O module 51C� 6250 W ]SOO W BJSO W I OOOO W Mox.DCpower�bmeq-1� 5300W 6JSOW 1a00W 8600W .••" �' ^ - . . _ � ^ .. • � —� Max.DCrdage 600V 600V 600V 600V � DCnom'unlydae� 310V JIOV JIOV 3d5V � 1 MPPrelaBemnae 250V-GBOV t50V-<BOV 250V-480V 300V-IBOV � MinDCrdmpe/a�nroNuge 250V/]ODV 250V/JOOV ]SOV/300V JOOV/365V � Y bbx.tnpncwmm/Pns"^BIaiDCdimwv�eel 21A/40A YSA/40A 30A/YOA 30A/YOA ,I; � '�.r,�. 36Amwmbined�amtml ]6AOwmbinnd�amiml J6AOcombMdimmiml 36AOcenbined�mn:nl � M b�y Nambm d MPP�mcke../ - . � ,'�� . �.( ' I/41DCfamnnea) ¢ Imed ur ngn par MPY wdo E I �e. ��'t,# . � OmPm(AQ i _ y,,,,� ,: AC nom�ml pawo SOOO W 6000 W ]OOO W J680 W BOOO W s - . �`�r,�3' ° Moy AC opporeni power SOOO VA AOOO VA ]OOO VA B�OO VA y �. , "'x�} �'% NammlACvohaee/odluYoble mrv/. xnvi. znv/• mwi• xnri. xnvi• m�v/. z<v/. mv/• :nv/. mvi• � I �� A�rOBi8���9� I�i-RVV tl� 1HV tY-MSV I�]-LOv ill b�v Y4 bfV Ib 330V 111 L�v SY V E11.3C�V 24 i0fv � ' 4£ qC ndlro e m 60H 59.3-60.SH: 60H 59.]-6D.SMz 60H �59.J-60.SHn' 6pH 59.3-60.SNz � .3 .:'. 9 W ncY �e c � z L & & � y ,� `����'�!�� ,• .. Moa ompe�arren� 24A 11A IBA ]9A 25A 12A 3dA TVA 25A 32A r; � � Pewerlanorl��tl 1 I I 1 � � K PAommndunan/mnnanionpbw. I/] 1/2 1/1 1/P 1/P I/I 1/] I/] I/I 1/2 1/1 � ' " q, ��i�y'�S� Hoemomn <4% �aX <dy ad% _ � rb y+F� E(Huanq � '� 4�S Moa fi�vmry 96.)N. 968l4 9ABM 96.916 968X G].OK V].IX 9494 9].OX 943% 9A5X ; •'�,_ CEC effdenry 95.5% 95.5X 95.5% 953% D53X G6.VL 955K 940% VS.OK pA0% 96.OX f �''�, � vrmeq�on den�es � y r ,�+ DCrweneqabniypo�eaon • • • • > '. � AC�horl rncui proleq on • • • • F ,.. :'e ,�, CvMr:mlVy�.cbkd/nllpdexma..emm�»«�ng�m� �/- •/- �/- �/- g lw:,£ , ri, r,o�eno��b../o.n.daevo,��eory i/m i/m i/m i/m � Gan ral dma Dimmuom(W/H/D�nmm�in� 4]0/615/P40 �I8.5/2n/Vj � �� DCD�uannead'mem�om�W/H/D�inmm�in� 18]/19�/190 �]/12/].5� g s .y ,,.� ; Pod.�Bdmenxen��W/H/D�inmm(m) J90/SBO/800 �16/23/31.5� � ' k� � �'�t;,- ��}u'. ocolzomenpeci.Ygdtna.ero�v/M/olammlW 3Jo/zao/Yeo (Is/9/111 � - . .. �:.. .N ..V. . .... �. . . . Wai M OCDncmnwwei M k IE11 . . .a. .. . 64 6 3.54 816 66 1a516 ].5k BIb ` / . . , a I V I 1 I 1 I � . � � � � w��4, .. � . r y� fba4ngwmpM/DCD'ornmeepoAmgwsgM 6llq 114JR�/<kB 19161 . • 6Gkp1152m%<kg�9161 & � : �a OOcmime�empemmre mnee Ilull power) -25 C..�AS C I 13 F. +113 il ' 4`�� y°G'�,��� Nalw emi»�on�ryp�wl� E4 dB�A� 45 dB�A� d6 dB�Af a9 dB�p) j x, � � im.�i�a�.�,�,a�,m��ow o.i w o.�w o�w o.t w c ��� ., tepology If�m�ulom.0 IF i�onilamer IF imnd<m�er If wndoemer � '' w.0 �; ' � .• CodngmnaP� Op�iCeel OpuCeal OpuCool OpiiCod � il ! M � Elemcmnpmieawnm�mg/mnnedomrw NEMA3R/NEMA3R NEMA3R/NEMA]R NEMA]N/NEMA30. NEMA]R/NEM�3¢ , �� ' FeuNrea . �c s�e''a.�'x �3� D+ b iew4�e/em •/- • • • �� 'r''�"`,� x,�'"�;'-r� w r v6'� /- /- /- B i���daa>aSdes/ah.+oan o/o o/o o/o o/o Y ULCertified Efficiem Safe Sim la wa,,,my:�o/is/zoym.. ./o/o ./o/o �/o/o Ho/o g P Cenilim�v.andpermaa�mwaow�tableon¢qeeq� UIV4I,ULI998JEEE154],FCCPaniS�CIouA6B�.C5AQ43No.101.12001 NOIE:US imenen ilu wnh 4dv e • FwcountrieslhdreqaimUl •97XpedeBitlenry •Gdoanici�dmim •Pmm�eda�amaicgnd V BpY 8 wni(icmion�ULV41/IEEE1547� •Op�iCaal'"aei.elemparaure �vd�apedetetlim' Dawoi�omu�olco�datom S mmapememayaiem •IntegaedDCdnconnedsand� •5ando�dlwwm. oOprtomlleam,a, -Nmo.9bNe Typedev�vl�on SBSOOd15 586000U5 SB)OOOUS SBBOOWS %} k � a ��.�"!--I Accessories i ��=_._—__� SUNNY BOY 5000-US / 6000-US / 7000-US / 8000-US � � � - — _ _ ' :^��°��N° I� ^°�^'~�'�' � Versatile performer wiih UL certification Lap `� ` � � � (L' � • — ^-' , • 'TL Co NS.rcF � Cemkbr8a� ae�.awa�dw s.Ru�w.�qk,ode.d .� The Svnny Boy 5000-U5,6000-US,7000-U$and 8000-US invertars are UL certified and feaNre excellenl eHicienry.Gmdo- � � �' o„m,,,�,y„ � ,d,d,�. „ — v -uovx 88 . - y� mrmsvircM secnaae..secau� aledpower dasses provide flexibilily in rystem design.Avtomotic gridvoltaga defeclion' and an integmfed DC dis<onnecl I -^ v.•o�ovx � m�� �I - s swilch simplify insbllalion,ensoring safey as well as saving time.ihesa models featore galvonic isolation and can be used � � � v' mr� �M s' � I000 Y000 300D aOJO SGOp l000 Nm F with oll lypes oF modoles-cryslalline as well as�hio-film. I -- -- Pc� -_� p a Toll Free+1 888 4 SMA USA www.SMA•America.<om $MA Amerita,LlC •US Pofere U5135t5eVB I CONFlDEN7IRL - 7HE INFORNr1110N HERON Jp6 NUMBFR J B-019 0 6 2 O O PRENlSE OMNEk AH�[ Salem DESf70P110N: DE9fY7: ���� VWONG �=���6� CON7AINED SHALL NOT BE USED FOR lliE CAGGIANO, MICHAEL CAGGIANO RESIDENCE /����,SolarCity BENEFlT OF ANYONE E%CEPT SOLARCITY INC., MRPo�i: YODUIES: Noa sHau ir ae oisaosm iN vmaF ars iN 14 PATTON ROAD 'r� RESI 26 YINGLI YL240P-29b 6.24 KW PV Array PMT TO O7HERS Wi51DE THE RECIPIENTS ��T�µA� �WN�,�m,�: SALEM, MA 01970 ORGANIZA710N, E%CEPT IN CONNEC710N X17H THE SALE AND USE OF iHE RESPECTVE ECOFASTEN L—FOOT 2—LAG & SC RAIL 3055 Clearview Way SOLARqTY EWIPAIENT. W17HWT THE WRITiEN PAYIENT IYPE IN 7FR: p PAGE NAYE: $NEET: REY: DAIE: T san Mateo,�A999oz PERMISSION OF SOLARqtt INC. 97U74O�OHO 3 (650)638-1028 I F:(650)638-1029 LEASE (1 SMA # SUNNY BOY 6000—US CUTSHEETS PV $ �2��2��2 (888)-SOL{JTy(]65-2989) I �.�,.��aR�.�am • • • . � � � The SolarCity L-Foot with Eco-Fasten QuikFoot optimizes strength,performance and aesthetics while structurelly attaching solar panels to composition shingle roofs. This engineered connection uses Eco- Fasten's"QuikFoot"technology to achieve a robust,watertight connection. Stainless steel baseplate combined with 6000 series aluminum L-Foot offers superb structural and fatigue strength,which in conjunction with anodization offers excellent corrosion resistance even in coastal environments. • Allows for 2 screws per standoff • Anodized L-Foot for long term corrosion resistance and best aesthetics • Na shingle wtting required i • Fast and error-proof installation reduces overall impact on roof I • Compatible with SolarCity Canopy Rail � • Rail is attached using Stainless Steel Fasteners Components Installation Instructions A. Stainless steel sealing washer&nut 1. Drill pilot holes in raker B. L-Foot � 2. Seal pilot hole with roofing sealant � , � C. QuikFoot Flashing 3. Insert QuikFoot baseplate and drive screws D. (2)t114 Wood Screws 4. Install QuikFoot flashing E. S[ainless Steel Baseplate 5. Install L,Foot with sealing washer and nut g A � • � 4� � B � ei' � � � C ° � 1 � E c :��: ���`SolarCity. JB-019062 00 PREYISEOMNEA AHdSalem o�on�: �g�,: ► , CONFlDENTIAL — 1HE INFpiMAl10N HEREIN JOB NUM�R =��.�� CONTAINED SHALL NOT BE USED fOR 7HE CAGGIANO, MICHAEL CAGGIANO RESIDENCE vwoNG .SOI�1 VI ` BENEFlT OF ANYONE E%CEPT SOLARCITY INC., YARI(ET: MOWLES ���`� NOR SHALL IT BE DIS0.05ED IN NHOLE OR IN RESI 2s YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array �� PART TO O7HER5 WTSIDE 7HE REqPIENYS - a ORGANIZAPON, IXCEPT IN CONNEC710N N17H �cr u,waax reouxnr�c snm: SALEM, MA 01970 iHE SAIE AND USE OF THE RESPEC7IVE ECOFASTEN L—FOOT 2—LAG & SC RAIL 3055 Clearview Way $OLARGTY EWIPMENT, IN7HWT 7HE MRITIEN pp�ENT 7TPL IN�ER7ER: PA'�� SI�ET: REV: DAIE: 5an Mateo,ca94a0z PQ2MISSION OF SOLARCItt INC. 'I sMA SUNNY BOY 6000—US 9787401080 CUTSHEETS PV 9 3/2i 20�2 T��650)638-1028 I F:(650)636-1W9 LEASE � � # � (eae�-so�cmpss-z4e9> I �+++*mlarcity.wm , . ABBREVIATIONS ELECTRICAL NOTES INDEX LEGEND _ LICENSE 1. WHERE ALL iERMINALS OF THE DISCONNECTING PVi COVER SHEET AC AMTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN � (E) UTILITY METER (6) BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS — MP1 INVERTER W/ INTEGRATED DC DISCO & CONC CONCRETE OF THE HAZARDS PER ART. 690.17. PV4 UPLIFT CALCULATIONS �"" WARNING LABELS. (3),(4),(5),(6) � COMBINER BOX 2• EACH UNGROUNDED CONDUCTOR OF THE PV5 SINGLE LINE D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 ELECTRICAL CALCULATIONS � DC DIRECT CURRENT BY PHASE AND SYSTEM PER ART. 210.5. PV7 CUTSHEETS � DC DISCONNECT (4),(5) EGC EQUIPMENT GROUNDING CONDUCTOR 3. A NATIONALLY—RECOGNIZED TESTING PVB CUTSHEETS (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN PV9 CUTSHEETS � AC DISCONNECT (3),(4),(5),(6) JURISDICTION NOTES EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL Q JUNCTION BOX — ALL W❑RK SHALL GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) � GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER C�MPLY WITH THE GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES O DC COMBINER BOX (7),(9) MASSACHUSETTS STATE HDG HOT DIPPEO GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC BUILDING C❑DE, I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). 1. THIS SYSTEM IS GRID—INTERTIED VIA A � DISTRIBUTION PANEL (1),(2) — ALL ELECTRICAL W�RK Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN UL—LISTED POWER—CONDITIONING INVERTER. O INVS INVERTERS RELIEF AT ALL ENiRY INTO BOXES AS SHALL C❑MPLY WITH THE Isc SNORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. iHIS SYSTEM HAS NO BATTERIES, NO UPS. �c LOAD CENTER (3),(4),(5),(6) 2011 NEC� kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY kW KILOWATT UL—LISTED LOCAiION PROVIDED BY iHE GROUNDED. MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED O DEDICATED PV SYSTEM METER LBW LOAD BEARING WALL 5. ALL ELECTRICAL WORK SHALL COMPLY WITH THE MIN MINIMUM HARDWARE. � CONDUIT RUN ON EXTERIOR 2011 NATIONAL ELECTRIC CODE. (N) NEW 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, 6. WORK TO BE DONE TO THE 8TH EDITION OF MA _ �A�UIT RUN ON INTERIOR NEC NATIONAL ELECTRIC CODE RAIL, BOXES, ETC.) SHALL BE GROUNDED USING STATE BUILDING CODE. — INTERIOR EQUIPMENT NIC NOT IN CONTRACT UL LISTED LAY—IN LUGS LISTED FOR THE 7, UL 1703 — SOLAR MODULES NTS NOT TO SCALE PURPOSE. POSTS SHALL BE MADE g. UL 1741 — INVERTERS OC r::ON CENTER ELECTRICALLY CONTINUOUS WITH ATTACHED p 'PANEL BOARD RAIL. pL PROPERTY LINES 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS PVC POLYVINYL CHLORIDE AND GROUNDED AT THE MAIN ELECTRIC PANEL. g SUBPANEL 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP SCH SCHEDULE SHALL BE SIZED ACCORDING TO ART. SS STAINLESS STEEL 250.166(B) & 690.47. i � SSD SEE STRUCTURAL DRAWINGS ���/F�°°dH� � �'`� � STC STANDARD TESTING CONDITIONS J tl � 0��s �� �'+�a `� gyN� SOLAR WATER HEATER j ''?�a , a. TYP TYPICAL ��� UON UNLESS OTHERWISE NOTED 1' � 4 A� � ; � o�o�r� � �afi01d UPS UNINTERRUPTIBLE POWER SUPPLY � � ` � °"'a V VOLT �/ �Pe `' ' Vmp VOLTAGE AT MAX POWER Y ' '' ° ""'�"�° • � � o�����°' �, Voc VOLTAGE AT OPEN CIRCUIT /� �*. ��:�"" *" � Ae � 1 . F�rs" W WATT ,/ `�,Ra �,s�' O ��,.. ` 3R NEMA 3R, RAINiIGHT 1'� � M� + . f � o� �p' � 5tatm�� ! - � Plckman� �F . � � -m� jr Pork , �5�� I � ��e .M1bXali Ae � . .c� � ���9 � . � v..e F � 9' , r ° �° , � REV BY DATE COMMENTS � a ¢� va�ftl�f 4 GrantRd yd' yyy��� REV• • ����� s � � ' �� ��` �-� . � � 3 , �� - y9a �. °4 �?e 7 °'aa °'Frma`^,,... s [ . .°� '�o V£�` .R��aae� _ ! n . � �r� . . $ �- ...�,yi''� � Pctman� �9�•. � � a � �. CONiIDEN7IAL- 7HE INFORYAlION HER�N Jp6 NUYBEk J B-019 06 2 O O PREN6E ONNQ2: N4[ Salem DESQtlP110N: OESIGN: '�� �' CONTAINED SHALL NOT BE USEO FOR 7HE CAGGIANO, MICH'AEL CAGGIANO RESIDENCE VWONG ������SOI��I� BENEf1T OF qNYONE E%CEPT SOLARq7Y INC., MRPoQL YWUIES: �' Na� s�u��r ee o�sc�os�o �N �ac «+ �N RESI 2s YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array '�� � IXtGANZA710N, E%CEPT�NECONNEC710NVA7H ��Tu�,A�R - .�WNnN�snhW: SALEM, MA 01970 � ° � iHE SALE AND USE OF iHE RESPECTIYE ECOFASTEN L—F00T 2—LAG & SC RAIL 3a55 Clearview Way ' SOLARqttEWIPMQVT, NI7HWTTHENRITiEN PAWENTTYPE M - PAGENAAIE $HEET: REV: DAIE: SanMMeo,CA99402 v�issiarr a satarsatt iec. 1 SMA SUNNY BOY 6000—US 9787401080 COVER SHEET PV 1 3/21 20�2 T:(650)638-1028 I F:(650)638-1029 LEASE � � / (888)-SOL{[ry(765-2989) I m++'+�larcity.wm , � - Roof Mounted SEEPV3 DETAILS A,B,C MPl PITCH: 22 ARRAY PITCH:22 AZIMUTH: 175 ARRAY AZIMUiH: 175 MATERIAL• Comp Shingle Roof STORY: 2 Front Of House LEGEND Q (E) UTILITY METER (6) OINVERTER W/ INTEGRATED DC DISCO & Inv �°° WARNING LABELS. (3),(4),(5),(6) AC ; � DC DISCONNECT (4),(5) 1 ,�-�i � AC DISCONNECT (3),(4),(5),(6) M � � � \=- I Q JUNCTION BOX 0 DC COMBINER BOX (7),(9) Q DISTRIBUTION PANEL (1),(2) �� LOAD CENTER (3),(4),(5),(6) B PV3 �u DEDICATED PV SYSTEM METER i — CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR M — GATE --- INTERIOR EQUIPMENT A PV3 SITE PLAN N Scale: 1/8" = 1' W E 0 1' 8' 16' S J B-019 06 2 0 0 PRFYISE OMNfk AHJ Salem D6tlEP710N: �E9GN: � , WNFlDENIIAL — 7HE INFORNA710N HEREIN JOB NUYBEIt � =��.�� � CONTAINED SHALL NOT BE USW FOR 7HE CAGGIANO, MICHAEL CAGGIANO RESIDENCE VWONG �� SOIA�I ` i BENEFl7 OF pNYONE EXCEPT SOLARCIN INC., y�T: NOWIES ��`� � NOR SHALL IT BE DISCLOSEO IN NHOLE OR �N RESI 2s YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array '�� rnar ro on�eas ouTsoe n�e rsEaai�xrs SALEM, MA 01970 ° ORGrWIZA710N, IXCEPT IN CIXJNEC710N Ni7H PR0.1E�T YANACER' MWNTINC SK1EY: 7HE SALE AND USE OF iHE RESPEC7IVE ECOFASiEN L-FOOT 2-LAG & SC RAIL 3055 Clearvien Way SOLARCItt EWIPNENT, NITHWT 7HE WRITIEN PAriENT 7YPE IN�E 7FA: PAGE NAME $HEET: REV: DAIE: San Mateo,CA 94402 r��assia� a� so�u�an iNc. �EASE (i� SMA # SUNNY BOY 6000-US 9787401080 SITE PLAN PV 2 3/2i 2oi2 T:(650)638-1028 I F:(650)638-]029 / (888)-SOLLITV p654989) � wwwsoWrcify.com . , 4' BETWEEN F0011NGS STAGGERED � 1'-4" T1P (E) 2x10 RAFTERS � i6" SPACING � FRONT VIEW OF MOUNTING PLANE V Scale: 1/2"=1'-0" (E) 2x10 RAFTER � � 16" O.C. NOTE: RAIL TO BE PLACED IN THE UPHILL DIRECTION Pv3 SOLAR PANEL INSTALLATION ORDER ATTACHED WITH MODULE LOCATE RAFTER, MARK HOLE (E) 2x12 CLAMPS, �"—i6 BOLTS, (1) LOCATION, AND DRILL PILOT RID6E 80ARD � � AND }" NUT (5) HOLES USING 1/8" BIT. 1x6 _ �� SOLARCITY SOLAR RAIL _ _ _ - (4) 22 & BOLT — — (2) PLACE 1HE QUIKF00T. I (E) 2x8 CEILJNG LEVELING FOOT (3) �3� ISEALANT AND SCREMS. .k-1' �2'—g" JOIST � i6" O.C. (E) COMP. SHINGLE �� (E) LBW (4) INSTALL FLASHING. ECOFASTEN FLASHING RAFTER: 2x10 U U �5� INSTALL L—FOOT Wlhi SEALING SUPPORT: ix8 (E) ROOF DECKING WASHER. MAX SPAN: 12'-8" TRIANGLE FASTENER #14 �2� (1) WOOD SCREW (3" EMBED, MIN) �� SIDE VIEW OF MP1 (E) RAFiER �� STANDOFF � � SCALE: � �'' Scale: 1 1/2" = 1' JB-019062 00 PREIIISEONNEA AH� $alem DESCPoP110N: DESGN: ► � CONFlDENTIAL — 7HE MFq2MA710N HEREIN ,qB NUYCEk `������ CONTNNED SHALL NOT BE USEO FOR 7HE CAGGIANO, MICHAEL CAGGIANO RESIDENCE VWONG �- NOREFSHPll ITNBENDISCLOSEO ISNXHOLE ORCIN NN&EL N�� 14 PATTON ROAD 'I,�SolarCit RESI 2s YINGLI YL240P-29b 6.24 KW PV Array PART TO O7HERS W79DE 7HE REqPIENYS o aacar+iunorr, occerr iN coNr�cnori mm ��T�^�+^� ��+�+�Sn�Y: SALEM, MA 01970 7HE SALE AND USE OF iHE RESPECIIVF ECOFASTEN L—FOOT 2—LAG & SC RAIL 3055 Clearnew Way SOLARCITY EWIPNENT, YAIHWT 7HE YA21TiEN pA�y�T 7YPE: INYER7ER: PAGE NANE: $HEFf: REV: DAIE: San Mateo,cn 9ca0z r�RuissiorroFsov,�aniNc. LEASE (1) SMA # SUNNY BOY 6000—US 9787401080 STRUCTURAL VIEWS — MP1 PV 3 3/2i/2o�2 (888)SOL{[TY(765Z2489)�I650�6,3�I�aicity.wm , , UPLIFT CALCULATIONS INPUT VARIABLES CALCULATIONSAND l/ALUES Required �ariables Design wind pressures based upon: Mean Roof Height: Z6 ASCE 7-OS Chapter 6 Wind Loading Exposure Category: � Equation 6.5.13.3: Component and Cladding Elements Basic wind speed(or city in the future): 100 W�nd pressure P=qh*Cn`G Importance factor(1 for residential): 1 6.5.10: Velocity pressure qh=0.00256'Kz'Kzt*Kd"V^2*1 Roof shape: pitched From Table 63: Roof Angle(degrees): 22 Kz=0.95 � . . - . . . . . . . . . . .Roof zone: 3 - . . - . . . .. From Figure 6-4: Contiguous sq. feet of array: 105 ��= 1.00 Least width of the building: 31 Obstructed wind flow? TRUE From Table 64: Kd=0.85 Local Topographical Featu�es (choose "standard "orrefer to pictures nght, and below) From fipure 6-1: V= 100 Type of hill: none Hill height(h)(ft): From table 6-1: Slope of hill(degrees): I = 1 Horizontal distance from hilltop to house(x): From Velocitv Pressure Equation Height from bottom of hill to mean roof height(z): qh=20.63 � Design Wind Pressure From Figure 6-196 P(Ibs. per sq.ft.)=qh•Cn`G Cn (uplift) _-1.41 Pd(downforce pressure)= g,77 Cn (down)=0.50 Pu(upliH pressure)= 24.78 From 6.5.8.1 G=0.85 Max TributaryArea Feet Inches Individual Rows in Portrait X (E-W distance between standoffs)= 4 0 � Yingli YL235 P-29b Y(N-S distance between standoffs)= 2 6 � Amax(sq. ft.)=0.5`L'X Staggered Penetrations= � Yes L(length of panel in k. perpendicular to rail) 5.41 Module Rail Max. Span/Cantilever(in)= 48 19 X= 4.00 r= iso Max Up/ift Force on a Single SbndoH` L= N/A Pmax(Ibs.)=Amax*Pu � Amax= 10.83 Z6$ Dead Load Calculations Factor of safety = FI��*NI/Pmax DL(Ibs/sq.k.)_(Mm+Mh)/(L'V1� 1/4 x 4 in. =Lag size and length � 375 =Capacity pbs)of 1 lag (NDS) L(length of modules) 5.41 � Z = NI(number of lags per standof� � W(width of modules) 3,Z5 2.80 = Factor of safety Mm (weight of modules)43.65 Point Load Ca/culations Mh(weight of hardware per module)= 4.15 PL(Ibs)=Amax'DL DL= 2.72 29 J B-019 06 2 00 PREYI�OYMFR AH�L Salem OEWtlPIIpl: �E9GN: � , CONFlDEN7IAL - iHE MFORNA710N HEREIN JIIB NUYBER: ����� CONTAINED SHAl1 NOT BE USED FOR 7HE CAGGIANO, MICHAEL CAGGIANO RESIDENCE VWONG �= . �EF��I�BENDISCLOSm INaNH E IX2CIN ""�T: °�"'�s 14 PATTON ROAD 'ii� /� t PART TO O7HFR5 W151DE 7HE RECIPIENYS RESI 26 YINGLI YL240P-29b 6.24 KW PV Array SOIA�I ` o , PRWECT MANACfR: I ORGANIZA710N, EXCEPT IN CONNEC710N N1TH �WN¶N�Sn,�M: SALEM, MA 01970 7HE SNLE AND USE OF 7HE RESPEC7IYE ECOFASiEN L—FOOT 2—LAG & SC RAIL 3055 Clearvmew Way . SqARCIIY EWIPNENT, YAIHWT THE MRITIEN , PAGE NAME $NEEf: REV: DAIE: San Mateo,CA 94402 � PAriFNT IYP. INYERTEk E T:650 636i028 F.650 638-1029 v�Missia+ o� so�axcrn iNc. LEASE (1) SMA # SUNNY BOY 6000-US 9787401080 ( ) I ( ) UPLIFT CALCULATIONS PV 4 3/z�/2012 (888)-SOL-CITV(7654489) I ��solarciry.mm � ROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) �B EGC/GEC TO (N) GROUND E 200A MAIN SERVICE PANEL Inv 1: DC Negatively Grounded (i)sMp SUNNY B Y 6000-US p — 6 NNqJ /YL2�OP-�b ROD AT PANEL YA1H IRREVERSIBLE CRIMP �E; 200/2P MAIN GRCUIT BREAKER INV 1 — In�x(-2011� 6000W, 277 2�208V, 96.OR/95.Sx/95.SS PV Nadule ( 2011 ; 240W, 215.9W PTC. H4, SOMM, Black Frame Voc: 37.5 Panel Number.MURRAY LC230PC Vpmaz:29,5 Meter Number.gg 652 621 �MOOULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN 7HE DC STRINGS IDENTIFlER OF THE SINGLE UNE DIAGRAM. MAIN SERVICE PANEL SOLARGUARD Inverter 1 (E) WIRING CUILER-HAMMER MEIER - � 200A/2P Disconnect 3 SMA � (e) �onos g C � SUNNY BOY 6000-US AMPHENOL • �� "0V Y Branch Connector 1 I� • N GFP/GFCI A D� 35A/2P Z �--- � � —___ �GND — _ — GND — __________--_—_—__— ._EGG _ � DCa ❑ pCa 25Mo9(s)OF130nMPl � A GEC — � ___ B � DC-____ _____________ _______�___ �C I I IGND __ EGC _________________'________ '__'_______ _ EGC_____________� I � I N � I 1 EGCIGEC � o _ _ z z � ' ____l i ___ GEC __ y — T TO 720/240V � SINGLE PHASE � U7ILITY SERHCE i � i i i i �_ OI ���WTIFR-HAMMQ� /BR235 PV BAqCfEED BREAKER B (1)CURIIt-HANMER /DG222URB AC ("��a/�rr DC Breaker 35A/yP„ 2 gpacea DiscmneHc• 600. 240�ac, Nm-Fuemle, NF1AA 3R A Y Branch Connector, H4, Mde —(1)Q�anA tfod: 5/6 z 8'. CapDer —���Gro�nd/NA��d�t; 6o-100A, Ge�al Duly(DG) —�1)�B Ndai ConHn�ta; H4, Femme C (ilsanacm y�sc uemt -(i)ax�c po, nivm-a e�aa� (sn) Mmitamq u�n mt; 208/240 2-Mue —(I)HOFFTAAN /A�R64 —(1)AN'G if0, THYM-2, Red (SftJ Endosice; NEIAA 3R —(2)Nu��4 AWG�Same sidePr�mAated —�1)AWG i10, THNN-2, (7een (sn) OT(1)ANG /8, 7HWN-2, Blad� 2)AWG /10. USE-2/RHW-2, Bladc Vac =q87.5 VDC Ix =17.3 ADC (4 AN'G /10, USE-2/RHW-2, Black Voc =q87.5 VDC Csc =8.65 P,DC IaF(1)ANG /8, 7HWN-2. Red O�(I)AWG /10. Solid Bare Cappc EGC Vmp =383.5 VDC ImP=16.28 ADC O�(I)AM'G /10. Sdid Barc Coppa EGC Vmp =383.5 VDC ImP=8.14 ADC �l.(I)AWG /10, 7HYM-2, Nfiite NEU7RAL Vmp =240 VAC Imp 25 MC . . . . ��(I)ConEuit qt: 3/4' ENT �I . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .. . . .... . .. . . . . . . . .... . . .. . . .. . . . . . . . . . . .. . . .. . . . . . . .. . . .. . . . . . . .. . .. . . . . . . . .. . . .. . . . -fi)awc_/e, niwr�z,.cre�. EccicEc. .-(l).co�a�n_gi4.?/4'�7...... . . . CONFlDENTIRL - 7HE 116qtMRTION HERON JOB NUYBEk J B-019 06 2 O O P�ISE ONNFIC AH�k Salem DESCPoP710N: �E9GN: `�� �� CAGGIANO, MICHAEL CAGGIANO RESIDENCE vwoNc �;,,,, CONTAMED SHALL.N07 BE USED FOR 7NE �- . BENEFIT OF ANYalE EXCEPT SOLARCItt INC., YpRKE7: MODUIES Solar�ity NIXt SHALL IT 6E OISCLOSFD IN MHaE IXt IN RESI 2s YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array ��� PART TO O7HfR5 WTSIDE 1HE RECIPIENYS SALEM, MA 01970 ° ORGRNRA710N, EXCEPT IN CONNEC110N N1TH ����µ�' WWN7ING SK7EY: 7HE SN.E AND USE OF 1HE RESPEC7IYE ECOFASTEN L-fOOT 2-LAG & SC RAIL 3055 Clearview Way SOLARpTY EWIPNFNT, N17HWT THE MRITfEN PAGE NAYL $HEEC REV: DAIE: 5an Mateo,CA9aao2 PQtMISSION OF SOLARq7Y INC. PA�ASEE �(i�"`SMA # SUNNY BOY 6000-US 9787401080 SINGLE LINE PV 5 3/2i/2o�2 T:(650)638-1W8 I F:(650)638-1029 (888)-SOL{Ry(]654489) I �'+w'solarciry.com 1. Conductor Sizing oe� Art 690.8(Bl(11 ELECTRICAL CALCULATIONS a. Conductor must have 30 deg. C ampocity >= 125% of continuous current per Art 215.2(A)(1). Module: `26"Yirgll YL240P-29b � 275.9 Inv Pwr W PTC StrLen Voltaae Drop CalculaBons Version 5_8.16 b. Conductor i7lUSl hOVC (ofter corrections for conditions Of USB� >= Imerter 1: 1�SMA SB8000US(240� �95�5"h 6,000 ,361i 11 Vdrop= (Imp) ' (2'Lenglh)'(Resistance) / (Vmp) Module: ! � Imp(A) Ma�c. Length(ft) Wire continuous current per Table 310.15(B)(i6). + Imerter 2: �. _ � ^�SVing: 8.14 50 C AWG 10 at Max A�e Hi: 82 deg F Module: f � ��Vdrop= 8.14 A ' 100 ft "0.00124 Ohms) / 355 V= 028% c. Evoluofe conducfor lempero{ure af ferminations per 110.14�C�. Imerter 3: ��111 � � Brench: 1628 40 C AWG 10 at Max Aee Hi: 82 deg F Ampacity of wire derated for conditions of terminotion must be >= Module: I ` ' � �vdrop= (16.28 A • ao 8 •o.00t2a ohms) / 355 V= o.45%a continuous current�1.25. All string terminotions are roted at 90' C. imertera: � _ Total wltage drop in DC conductors= 0.74% ----------------------------------------- � i Inverter. 25.00 10 C AWG 10 at 240V 2. OCP Sizing per Art 690.8f Bl(11 Total: 28 modules Total Inv Pwr �_6 000 5 361 PTC Vdrop= (25.00 A ' 20 ft '0.00120 Ohms) / 240 V 025% a. Round up fo nexf size per Art 240.4(B) Photovolfaic Module Electrical Specifications: Total STC �6,240 � Combined 25.00 0 E AWG O6 at 240V Voc= �37.5 V deg F deg C Vdrop= (25.00 A ` 0 ft `0.00049 Ohms) I 240 V 0.00% ----------------------------------------- Vmp= 29.5 V Record Low Temp: -9 -22:778 Total wltage drop in AC conductors= 025% 3. Conductor Sizinqper Art 690.8(B)(11 Isc= 8.65 A Max Aeerage Hi Temp: 82 27.7778 Total wltage drop in AC and DC conductors = 0.99% a. Conductar must have 30 deg. C ampacity >= 125% of continuous imp= 8.1a n current per Art 215.2(A)(1). 7wc= -o.13s8 videy C Tsc= 5.19 mA/deg C b. CondUCfOf mUsf hove (ofter corrections for Condilions of use� >= Strina Tvpe A and 2 Combined Strinns Tvpe A Voc Correction Method: Manuf Twc dat Brench Circuit Type A �-way wire length: 40 fl SMA SBFi000US�(240V) ��� � 2 strings per branch 1 continuous current per Table 310.15(B)(16). �s'vinyii v�zaoP-zsb ImeRer Min Vdc Input: 250 Vdc � 13 modules per senes slring Voc= 487.5 V Min Vmp at Max Temp: � 355 Vdc Voc= 48 . V c. Evoluate COfIdUCLOf temperature at terminations per Art 110.14(C). vmP= 3s3:s v Max Voc at Min Temp: 574 Vdc Vmp= 383.5 V Ampacity of wire deroted for conditions of termination must be >= isc= e.ss n ImeAer Max Vdc Input: -600 Vdc Isc= 17.3 A continuous current*1.25. All branch terminotions are roted ot 75' C Imp= 8.14 A Max Slring Size: 13 Imp= 16.28 A mi�. Icont= 10.81 A Art 690.8(A)(1) 1-wa wire length: 50 ft Icont= __ _ 21.63 A Art 690.8(A)(1) __________________________________________ 7.a Conductor: C AWG 10 USE-2/RHW-2 ffi 90 deg C:Table 310.15(B)(16) 2.a Conduc�or 1:CAWG 10 THWN-2/USE-2 at 90 deg C: Table 310.15(B)(16) 4. OCP Sizina conductor t: a. Round up to next size per Art 240.4(B) Icont' 1.25=(Amps) 3.5z icont' 1.25=(Amps) 2�.03 ------------------------------------------ 30 deg C ampacity= 40 30 deg C ampacity= 40 5. Conductor Sizingper Art 690.8(B1(11 �.n Icont= (Amps) �o.st z.n Icont=(Amps) 2t.63 o. Conductor must have 30 deg. C ampacity >= 125% of continuous start ampacity 4o start ampacity 40 cu��ent p0� Arf 215.2(A�(1�. Temperature derate(%=F) 0.76 Temp. derale(°/=F) 0.76 CoMuit fill derate(%_#) 1 Cndt. fill derate(%_#) 1 b. Conductor must have (ofter corrections for COIICJRIOfIS Of 1158� �= Derated ampacity 3o.aD oerated ampacity so.a Tertn 7 Term 2 continuous arrent per Toble 310.15(B)(16). tc Icont"125=(Amps) 73.52 Temp table 75degC 75degC Ampacity 40 2.c Iconl'1.25=(Amps) 27.03 27.03 a Evaluate conductor temperature at terminations per Art 110.14(C). ampaciry ___._ 35. _____. 3_ Ampacity of wire derated for conditions of termination must be >= t.d icont' 125=(Amps) 13.52 2.d e�c CAWG10 CAWG10 nrt. zao.i22 . continuous current*1.25. All inverter output terminations are rated at ocP size= 7s ocP size= 30 75' C. ------------------------------------------ Inverter7vue A Outaut 6. OCP Sizina SMA SB-6000US(240V)�, 1-way wi2 length: 10 fl Icont= 25.00 A AA 690.8(A)(1) a. Round up to next size per Art 240.4(B) 3.a icom*125=(Amps) - 31.25fA Art690.8(B)(1) OCP size= 35 A AA. 240.6(A) 7. Conductor Sizing per Art 690.8(B)(il 3.b Conductor C AWG 10 71-IWI�2 at 90 deg C:Table 310.15(B)(16) a. Conductor must have 30 deg. C ampacity >= 1259 of continuous Icont"1.25=(Amps) 3t.z5 current per Art 215.2(A)(1). 3o de9 c ampacit = ao 3.c Icont= (Amps) 25.00 Slart ampacity '40 b. Conductor must hove (after corrections for conditions of Use� >= Temperature derate(%=F) o.si continuous current per Table 310.15(8)(16). Conduit eu derate(/=a) � Derated am acit 38.4 c. Evaluate conductor temperature at terminations per Art 110.14(C). 3.d icont'1.25=(Amps) 31.25 Ampacity of wire derated for conditions of termination must be >= Ampacit 3 con}inuous curren{*1.25. All inverter output terminations are raked af 3.e EGC/GEC = D AWG 08 Art. 690.47(C)(3), 250.166(B) 75' C min. CONFlDFNIIRL- 1HE INFORNR7IIXJ HERON J09 NUI�ER J B-019 0 6 2 O O PREYISE OMHEIC RHd Salem OESCRP7IW: OESIGN: `�� �' CONTAINED SHALL NOT BE USED FOR iHE CAGGIANO, MICHAEL CAGGIANO RESIDENCE vwoNG � ��� Solar�it o NIXtESHALL ITNBENDISCLOSm INaNHCOLE ORCIN u"�: "�"�s 14 PATTON ROAD 'n PART TO O7HER5 WT9DE 7HE REqPIENTS RESI 26 YINGLI YL240P-29b 6.24 KW PV Array ORGANIZA710N, EXCEPT IN CONNEC110N M7H �Ci MANAGLR �o�,nN�5,��: SALEM, MA 01970 7HE SNLE AND USE OF THE RESPEC7IVE ECOFASTEN L-FOOT 2-LAG & SC RAIL 3oss cieaM�w� SOLARCITY EWIPMENT, NITHWT 7HE WRITIEN PAriENT IYPE: W�(R7ER: PAGE NAYE: SiEET: REV: DAIE: San Mateo,Ca 9aa02 PERMI$$ION OF SOLARqtt INC. LEASE (1) SMA # SUNNY BOY 6000-US 9787401080 T:(650)638d028 I F:(650)638-1029 ELECTRICAL CALCULATIONS PV 6 3/21/2012 ceee,-So��mnbs-2989> i ,,,,�,,.��a2�n�.mm YL240P-29b � �� � ��� Y1235P-29b � � �� YC7E Z�O SERIES YL230P-296 VIN LAft � SERIE� YL225P-296 � EIECTRICAL PERFORMANCE �'mw"" GENERAL CHARACTERISTICS ModWerwme • YGE1/0 YGE235 � YGE230 YGE]SS oimemlmshrwMl Ifa%�tMwmN/38.vBurywMN/ _'._—__-__'___— '"'_"' . _'—_ _ .__"..___ ___"____.. MetlWelype YLNOP.296 YLi�SP-196 Y1 LZIOP-396 Y1115V336 I i.9)n150mm1 �`.�M PA N v °pw °'"^°` P w ' xm zas ao ns we�qw a.o�ncs kql . . ---- '-- -� -- - - --- � ---- - P romputmbr GP..� % / 3 � � . �. � _� -� �`_ YingliGreenEnergy(NYSE:YGE}isoneoftl�eworld'slargestfully M�•��Mr _ __ �o- x - ia� +aa ia.i us r . ■� verticallyintegratedPVmanutac[urers.Withover2GWofmodules v�ms•�.*R^+• � v.,, J zvs � � zas � ns zas . PACKAGING SPECIFICATIONS . --_�--.... , _..__ installed globally,we are a leading solar energy company built upon CinenO°'°ina � a e.ia o.v� o.eo o.w r+�,w,.w,�,e�ro,p«w�b� zo proven product reliahility and sustainable performance.Founded °pen`�""�"a"9°__ — _�" v __a�s � 3zo 3za ass H,,,,,�„�o,��srm,n.::. se snan.aai ��mm �- A aes esa ewo e.za m„ .-_-_—_ ----_- _— in1998,YingliGreenEner9YservescustomersthroughourLLS. s��,�o«���„m:,�tt.a•c����.,��.�,nm�sg�,����a:S�oeNswo<a - � �� - P""s'^a°eienb^�'°^��^'� sr�n:ao�.�ui.s��u,w�n� � subsidiary,YingliAmeritas,co-headquarteredinNewYorkand '�^v^v�aw�,�.=w��•wuaa.�,�. � a�anwom,,.� San francisco.We are the first renewable energy wmpany and the e�•��d�+ ___ ��sn is,uz>�i� . {irst Chinese company to sponsor ihe FIFA Worid Cup`. � � � �� romrewpue __"'__'__ vo. w u�3 no.v 16).0 163.! Units:iMh(mm) I� � van.q.xr..� v.,, v � ma aee zee me i PERFORMANCE --- - — -- — -- �� A� i Cumnt el F... 6av 4 6 SS 6 Q 629 !15 -� � -- -Industry leadi�g in-house manufacturing o(polysilimn,ingots, oc.,.�;,,,,n.,io¢a � vR v . ^ x� � aa.e �aa.e �' ana n.z. m� i.mmw � wafers,cells and modules ensures tight control of our material sn,n<���a�..�e k a �ui asz esi e.n and production quality. Hocr:wm.�:�.:�a�,�,�y�ienm�,�.�e�wi„2:.„n,.�.�.mc..�sm,�nm�.b�2.imi:m�W� 0 ;� -Higb performance,multicrystalline solar cells deliver a module series efficienqotupto14.7%,reducinginstallalionwstsandmaximizing 7MERMAL CHARACTERISTICS � [hekWhoutputperunitarea. r+�iw..•u�g��o,mo..m,n wcr �c ae.az -Powertolerance oi+/-3%minimizes PV system mismatGh losses. um�..mn.,.R�amerr.._ r +�'� �o.�s � TemWiatun�wflici�mofV� . . p.. . Y+'C.. . . . .0.]) .. . � . . . �2i�6�(61m6' � � � QUALITY & RE�IABILITY r,,,,..,,�„�„,�,,,,,,k ,., � a.�, a ; � -Robus[,cormsion resistant aluminum frame independenttytested — to withstand wind and snow loads oi up to 50 psf and 113 psi, I OPERATING CONDITIONS I respectively,ensuring a stable mechanical life. „A���a.w.�a s m,,.:y.e.m.a<ayo eoovoc — -Manufacturing facility cer[ified to 1509Wi Qua�ity Management m....o.p.w.a.�y isn � System standards. --__ _ __— .__ _ __.- _____ ________ _____--_-_—.__-_ - a-°rm rHi n n Oporallrrg tpnpwap,ro nnge .GO l0 190'F�-00�O 50'Q '�,.� � .__ _... - '. 4_ _. -Module aeka m o imizedto rotect mductdurin � � ---� -------�--�- -��--- — P 9 9 Pt P P 9 -r.,..ua<w.a,����ay �...,a.:�a�--_ -_. ii3N�uoare� .. ' a transpoftation and minimize oo-site waite. M,,,na4��.y,��p.s.,�;�� 5pps(Q400 Pal -- � :' ' �� _ ._.... _. .. . . . : 0.<)Pb � WARRANTIES ���.�.�, �:.a�,,.,,,,�s,m�uaM,� - '- -Extensive 5-year limited praduct wartanry and a 25-year limited power /`' : , warranty. CONSTRUCTION MATERIALS i � ; -Limitedpowerwarranry'=909ooftheminimumratedpoweroutput °iant°°`"'0"""�vy"°""�"°"j la�warongbsslmmpnodl3.]mm ;, s sE�"�"°-^ � E'� , for 10 years,80%of the minimum rated power output far 25 years. uuta�a��m+,�u�yoda�m�w�,�„i saicw�sm���,,,,n��y uumai � J iiammxtSAmmlla3.JmP •I�wmpla�ewidiourwarramymrmsandwrxfinans. Ene�p iam(msea�l Emyinmw.yiacv2ta(EV� _ P . ... �.�` t��'' : ' fmna4nrteriaViceb�i nMnimvndlN'lawdized�mbh6 �_'_ � Q.UA6IFICRTIONS &` �ERTIFICATE5 ���nw„eo.w�u�a<s.� iras L wm .�yaeae�o-.���dco��w�x.w��i�t�e��;e�r UL1703arrc1ULC1703,11LFireSaferyCWssC,CEC.FS€C,1509001:Za08, Cabielryo�g�dgn+ge/mm�ded eteq pv�e�n,3tm(�zppmMl��awGlO�ai�nldam� ��b handliginsullmg,andepevergYmgimod�kz_ _�,�,a_ _ ,�, 15014001:ZOOD,BSOSHA518001:2007.SA8000 PIu9�nnasw ,vnphemliwlirm (mawhttiraNtyPe�M�actlai aprW O OurPMr�ns C L u$ '.r~ �r � ��� •Thaspeci(kationsinthisdatasheetueaotguamnreedaedares�Ajectrochangewithwtpriarnmice. wom��w�umati �. NOD .d,� _ —_ . Yingli Green Energy Ameriws, Inc. /` � . � ��,�� . � info�yingliamericas.com � Tel:+1 (888J 686-8820 ��,,,_ �� � ' �—�--� � YINGLISOIAR.COM ( NYSEcYGE � � YINGLISOLAR.COM � YngliAmericas � __— -, � ` \ _ . � -� �Y��G�m.Ena�ss HNdro W Lui � YGE,2��Sa'cLFN IOnO)v51 CONiIDENTIAL - THE INFORNA710N HERQN ,pB NUMBER J B-019 0 6 2 O O PREYISE OWNEN: N!k Salem � DEStltlP710N: 061GX: `�� �' CONTAMED SNALL NOT BE USED FOR THE CAGGIANO, MICHAEL CAGGIANO RESIDENCE vwONG •- . BENEFlT OF ANYONE EXCEPT$OLARCITY INC., ypRKEF. YODUIES } NOR SHALL IT BE DISCLOSED IN YMIXf OR IN RESI zs YINGLI YL240P-29b 14 PATTON ROAD 6.24 KW PV Array ���,SOI��I ` PMT TO O7HERS Wi9DE 7HE REpPIENYS ��T�A� 40�,�,�5,5,�: SALEM, MA 01970 ° ORGANIZA710N, EXCEPT IN CONNECTION N1TH THE SALE AND USE OF 7HE RESPECTIYE ECOFASTEN L—FOOT 2—LAG & SC RAIL 3055 Clearriew Way SOLARqN EWIPNENT, Ni1HWT 7HE NRITIEN PAGE NAYE: SHEET: REV: DRIE: san nateo,ca 9aaoi PQtMI5510N OF SOLARqtt INC. PALEASEE M(��� # 9787401080 CUTSHEETS PV 7 3/2�/20�2 � 1 SMA SUNNY BOY 6000—US T:(650)638-3028 I F:650)638-3029 (888)-SOL-CRV(J65-2989) � wvnvsolarcity.mm � rad����damo s���reors000us s�o�reore000us s���reor�000us s���resya000us iOBVhC LOVRC ]IIV.K 308VAC LOVK fnYK xmVAC LOVK ]nVK LOVK xnVK SUNNY BOY 5000-US / fi000-US / 7000-US / 8000-US Inpu��DC� Ma..re<ommended PV pwa�O modub 5TQ 6250 W JSOOW B�SO W IOOpO W Mox.DCpower�0aaay-1� 5300W 6350W 1d00W 8600W r - � . � � " -�""��' -^� Ma�.DCrdwee 600V 600V 60pV 600v 1 4 _�_ � � OCnmmlmlvolwB� 310V �IOV 310V 345V � MPProboBemnBe ZSOV-480V ISOV-d80V RSOV-ABOV JOOV-d80V ' � � Min.DCrelepe/�mnralbae 250V/JOOV YSOV/JOOV 150V/300V JOOV/365V T MaxmpNexrtN/pmYring�olDCdirametl) 11A/POA 25A/20A 30A/20A 30A/YOA .. � '�� � 36AOaanb�edimm+rol 36A6combinad�em�onl 36AOmmbin�d�a�mtml �6AOcoAbinediamuwl � �' i �d �'. NumberdMPV�mden/ o i-��e �/4 IDC d�monroal ypZi� �3, � i;. . Iu�edm�np.�PerMVPimdm n ! � . :, �� *� a ' OutP��IAC) i ` �•4 �4 � � �� k� . AG nwniml pawa SOOO W 6000 W ]OOO W 1680 W BOOO W � r' ��'F.. :xs 1." �: .. t2x Maz ACoppa.enlpow« SOOOVA b000VA JOOOVA 9000VA E �.. . '��t* xr` �y�` ys : . Nemi�lAC.olme�/odrywbb ro�v/• vnvl. znvi. m�v/. .mri. :nvi. m�v/. zovi. znvi• xav/. novh i �°j'�' �]J � .. AC.oh.pem�ge in-ssssov m zuv v..owv iu-aov vi.xa.. au xsv iu.nev :i� un zu sev v� xa.v z...m�v 4 i �, � krt"���M�i`�`� 'y��� . ACetldirewen<Y.mnBe 60Ha593-605Mz 60Ha59.3 CO.SHz 60Xa593�60.5Mz 60Hc5G3-605Hz F - {�. _ . ��":. Mo..ou�pNane�n ]dA 11A 18A 29A 25A 1RA J4A ]9A ]SA J2N � t ,t : & � PowerladorlmsPl I 1 1 I i r. , e ' 5'k',,.� . . v�..w�a�na../�a,�,�mo,ab... i/z i/z i/i i/z �/z �/i i/a i�z i/i �/x i/i Sp � +. �J�2 � Ho.meNc. <dX �dY <dK �A% p �S ? Effldanry �, � . Ma�.elhnenq 96JX 96896 9G8% 96.9K 9G6X 9l.tlK 9].1% 96.9X 9).0'.K V6316 9ASX �. � � CECelfiai.nry 95.SK 95.5X 9i5% 95SX 953% 9G0'L 955K 9G0% 96.0X 96.0% 96.0% yP ^ �.� ProMtlian dav ua g � °jµ DCrmeno-pebirtypa�eaon • • • • I J �„ . nC ahon rircui pram�en • • • • � # � a � � i�, `� =`!f.��'{� Gel.er:mlly�.��ed/eupak.ema.emmawinpuna �/- �/- •/- �/- • ;�F,�s�;�, s # v.a�a�o�d,.,/o.n.dmaew��ory i/in i/m �/m i/m 6 n. .. General dala � D�men9om(W/H/D�mmm�in� A�0/5I5/2C0 p8.5/P</9) � DCDuconnead'm<m�orolW/M/DlNmmlinl I9]/24]/190 V/12/J.S� P Vack'ned�mmAen.�W/H/D��mm(m� J90/SBO/800 �16/Zl/3L5� E < < � �., ���'� �CO�cmenpv�tlgdma.oropv/N/D�hmwltil 3l0/IEO/280 115/9/111 F r ,m; We,eA�/OCDavmnedwaeh� 64ke P41161/J.Ske IBIbI 6640Ud5161/3.54g�816� q � °Fa;,`;�`',s'". ' VacBngvrepN/DCD'ernmvepoMgragM 6]kp (Id)bl/akB 19161 b�k8115]Aj/a481016� g � ^„,i�`y� , " Opemine�empaeWremnpeQdlpowe.l -YS'C._*d5'C (-13'F._�113'F� ' �ar Nol.a emianon�rypiwll d4 dB�A� d5 dB�A� d6 dB�Af d9 dB�A� y '"� In�errmlmnwmp�ona�mgN 0I W 0.1 W 0.1 W 0.1 W ¢ . � IoP�BY lf�mnilwmer lFtmndwmer lf�mndarmm lFEondarme� .! '� �� � CmfnBroMept Opt�Cool OpliCod Opt�Cool OpeCoal � t ElecfiomopeteNanmtin8/cen^eCionomo NEMA3Y/NEMA3R NEMA3R/NEMA�R NEMAJ0./NEMAJR NfMAJR/NEMAJR E ��'�T v � fevl�rn � � � � �"FY .q Oi�pby.�enline/yophk �/- •/- •/- �% � Imubce.45d85/Bh.laah o/o o/o o(o o/o ULCertified Efficienl $afe Sim Ie Woemmy.l0/IS/20ymn •/a/o �/o/o •/o/o �/o/0 9 P Cen�Cmbw�dpemealmwaawi6Weanwqus�� UlV<t,Ut199B,1EEE159],FCCPanIS�tivuABB�.C5ACP22Ne.10].6Y001 � • ForcoonfrieslhNreqvireUL •979:peo4eNi6enry •Gdvanicisdmion •Pmmledautanaicgid NOlf:USim.<nm.�h�vwtingmylid.. wnilicmim�UL1741QEEE1547� •OptfCod""vai.elemparmure .dmgederedlan' . Dawa�nom�ml<ondnon. .N mrnogamenisysiem .Inte�aedDCdsconneas..dfd� •Sa�do�dfmtme� oOP���llmmm -NmowJoble t Type dN�ofan . SB SOOOUS SB 6000U5 SB]OOOUS SB BOOOUS % � `��yrgpq�ppq%L-- Accessories . � f--�__ � Ipg . . �. �- . . _.. . �_. .. o PS�BSundu� SUNNY BOY 5000-US / 6000-US/ 7000-US / 8000-US � �^ _.__-•� •` ."°�'°�"<"" � °'"'""`�Y�' F Versatile performer with UL certification � � / d . + . . • . . LT � � Com6:5+,cF � moeneu,m^ 6 The$unn Bo 5000-U5,6000-U5,7000-USand8000-USinverfersareULcertiFiedandfeatureexcellenlefficienc Gmdo- r � �f �� ' & �" oce�e�w=eaw � s.qu�...eb.=.k.d .� Y Y Y� — r.-zovoc I a�r<a�'�r.�ee. a�dd.y ated power dasses provide flaxibility in syslem design.Aulomo�ic grid voltage delection' and on integmlad DC disconnecl w ' __ �. � coMm.svr�rch secnsn..secae� e norx !b -�" V.�.le6vu[ � Y�M c switch simpli(y installolion,ens�ring safety as well os saving time.These mode6 feaNre galvanic isolalion and<an be�sed W I IOOC �000 300p IOro SOGD EOW JOOG� a with oll lypes oI modules-crystalline os well os thimfilm. L _K� _____._...J � � Toll Free+1 888 4 SMA USA •usPo��..un�sss.vei www.SMA-America.com SMAAmerica, ��C J B-019 06 2 00 FREYISE OMMEIC �s ��� oE��: ��: �► , CONFlDEN7IAL- 7HE INFORMA710N HERFIN JOB NUI/BER ���r�I CONTAINED SHALL NOT BE USED FOR 1HE CAGGIANO, MICHAEL CAGGIANO RESIDENCE vwoNG •- . BENEFlT OF ANYONE E%IFPT SOLARCITY INC., yAR1�T: YODUIES 'I,�SolarCit o NIXt SHALL IT BE DISCLOSED IN WHIXE OR IN RESI zs YINGLI YL240P-296 14 PATTON ROAD 6.24 KW PV Array PRRT TO OTHERS WTSIDE THE REqPIENT'S pRQ�CT NANAGER wo�,nN�Sn,��: SALEM, M A 01970 ORGANRAPON, E%CEPT IN CONNECTION N97H 3055[learview Way iHE SALE AND USE OF THE RESPECTYE ECOFASiEN L—FOOT 2—LAG & SC RAIL PAGE NAYE: SHEET: REV: DAIE: san nateo,ca 9a402 SOLARqTY EWIPNENT, YA7HWT iHE NRITIEN PERMISSION OF SOIARqTY INC. PpwENTiYPE �"�SMA # SUNNY BOY 6000-US 9787401080 CUTSHEETS PV g g�2��2p�2 T�I650)638-1028 I F:(650)638-1029 LEASE (888)-SOL{ny��65d989) ( wvhvsolarcily.mm • • • • � • � The SolarCity L-Foot with Eco-Fasten QuikFoot optimizes strength,performance and aesthetics while structurally attaching solar panels to composition shingle roofs. This engineered connection uses Eco- Fasten's"QuikFoot"technology to achieve a robust,watertight connection. Stainless steel baseplate combined with 6000 series aluminum L-Foot offers superb structural and fatigue strength,which in conjunction with anodization offers excellent corrosion resistance even in coastal environments. • Allows for 2 screws per standoff • Anodized L-Foot for long term corrosion resistance and best aesthetics • No shingle cutting required • Fast and error-proof installation reduces overall impact on roof • Compatible with SolarCity Canopy Rail • Rail is attached using Stainless Steel Fasteners Components Installation Instructions � A. Stainless steel sealing washer&nut 1. Drill pilo[holes in raker B. L-Foot 2. Seal pilot hole with roofing sealant C. QuikFoot Flashing 3. Insert QuikFoot baseplate and drive screws D. (2�#14 Wood Screws 4. Install QuikFoot flashing E. Stainless Steel Baseplate 5. Install L.Foot with sealing washer and nut � A � - � � ! � B � '� � C � � D ' � � E �.�,, '���$OlarClty. CONFlDEN7IAL— 7HE INFORNA710N HEREIN ,pB NUY�R J B-019 06 2 O O �W�ONNER: AIAt Salem OESCPoPTION: pESIGl: `�► �. CONTAWED SHALL NOT BE USED FOR iHE �� BENEFlT OF ANYONE E%CEPT SOLARCITY INC., ypp�T: y��S CAGGIANO, MICHAEL CAGGIANO RESIDENCE VWONG �.,��; NOR SHALL IT BE OISCLOSED IN WHOLE OR IN 14 PATTON ROAD � ��� SolarCit RESI 26 YINGLI YL240P-29b 6.24 KW PV Array PART TO O7HER5 WTSIDE THE REqPIENTS o ORGPNIZAlION, E%CEPi IN CONNEC710N YA1H ���T��A� ��N�Sn,�: SALEM, MA 01970 7HE SALE AND USE OF THE RESPEC7IYE ECOFASTEN L—FOOT 2—LAG & SC RAIL 3055 Clearnew Way SOLARCIIY EWIPNFNT. YAIHWT 7HE NRITTEN PA111FNT TYPE IN\fR7ER: PACE NAME: $I�ET: REV: DAIE 5an Mateo,Ca9a4o2 r��issroNasow�aniNc �EASE (1) SMA # SUNNY BOY 6000-US 9787401080 CUTSHEETS PV 9 3/21/2012 �g88)SOL{ITYQ65Z2989) I650tt6Y38�1a¢Ry.mm