Loading...
22 ORNE ST - BUILDING INSPECTION 1 I lit: Cbnnnonwcalthul'iV1;us;tchusclts �1 ' tj DuarJ of Duilding Regulations and SLutJ;trJs ( I I OF r is urhusctts� Slate Building CuJe, 73U('MR ALli�l ') (►U building Pcrnti( Application TO Construct. Repair. Renovate Or Demolish u /r.•ri.tr/ ILu 'n// 1 d l)ne-ur Tim-pinndt'Du�/rr.Y This ion For Ot: ciul Use Onl Building Permit Number: Date, p ied: �� v to .emu_ �Tzz , �� sit Building 0111viii(Print N,une) 1 — Si - batc SECTION is SITE INF IATION I,I Property Address: ?,2 1.2 Assessursp dt,Ni Parcel Numbers E I.la Is this an acre led stteet? es no hlap Number Parcel Nunthrr I.J Zoning Information: 1.4 Property Dinsenslonsi Luring District I'nrpuseJ ll--- --_ Lul Amu Is III 4 Pmntnge(Ill 1.5 Building Setbecka(R) Front Yard Site Yun4 Rryuired I'ruviJed Required Side Rryuimd Near YardProvlJed 1.6 Weter Supply:(M.G.1.c. a0,§!4) 1.7 Flood Zone Informations I.la Sewsgs Dlapossl System: Ihtblle❑ Private❑ zone: _ Outside Flood zone? Check IY es❑ Municipal❑ On site disposal s).uetn O SECT ON 2: P OPERTYOWNERSHIPt 2.1 Ownert of Re"rdt Ni"llu(print) Uq,SWtu,L.IP c?� -Zia�ssa Nu.unJ Strcrt fetrphons Einuil Address SECTION Jt DESCRIPTION OF PROPOSED WORK'(check all thst apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repoirs(s) ❑ Alterotlon(s) Addition ❑ Demolition ❑ Accessory Bldg,❑ Number of Units Brirf Description of Proposed Work-: •fez ir7 f/ 7M' — — Other O Specify: _ r--i\ 4/yf-F SECTION 4: ESTIMATED CO,VSTRVCTION COSTS 11cm Estintated Costs: ILabor and%Luerials) 0f31clal Use Only I OuilJing S I. BuilJing Perms:fee: f Indicate how fee is JetrnnineJ: 2. k'Iccirical S ❑Standard City:Tuwn Application Fee s Phunhiity S ❑Total Project Oust'Ulens 6).1 multiplier '. Other Fees: S J. \Icchdnicdl ill\ \('1 j List: \1"Imllivd Ifni Cu .re.>iunl S facd \II FCef: S_ n fatal Project Cn.l: i !?/ QOO Cla'cA \'u. -- .--< hecA .lmtnml: . _. .._. .('.I.h \,,I.wnC ❑ P.iiJ ro FuU ❑OalstanJing ❑dl.mce Due: ION SF.RVI( FS I I pe ed I Ilk"Idil s ti t "Ip 111r,"ll.11 05 4o. mij mrcVt \Ijsoll KC K,%WITI1 col 'ri nil %A injll%% uIJ Sidtill .SF sulij FUVI liuming Applia"CV9 I Illsuluilorl 1) Dellioliti0ft l'eie hunt entail address Irliprovenlerst Contractor(1110 1,2 Registered 110111 II IC 11ell.u.1tion NuallM 1:,limilion DAV III('C,,Illpjll) N'11110 r IIIC li4lill.strunt Nailla ------- ---Iumail addirvit Nu,wid SLMA rVIV hone City(row state ZIP INSURANCE AFFIDAVIT(r4.G.L C. 153-1 25CM) I Hown.S WORKERS' COMPENSATION SECTION 61 WORK C����,P�Iettdand submitted with�Ihls application. Failure to provide Workers Compensation Insuran a affidavit must be COO this atyidevil will result in the denial of the Issuance-of the building permit. Signed Affidavit Attached? Yes ..........a No...........Q loRIZATIONTOSEPCOMPLETED WHEN SECTION 7&1 OWNER AUTHORIZATION BUILDING PERMIT B OWNER'S AGENT OR CONTRACTOR APPLIES FOR 1. as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building Permit application. �Mts iiinutule) ------ ------ SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below. I hereby attest under the pains and penalties or perjury that all of the Information contained in this a icat on is t nd accurate to the best or my,knowledge and understanding. No ------ o%vner\vho hircsin unregistVred k:ooIr1%;I0r I. ------- 7abuilding permit to do his her o\vn %vark.oran\vill LU) have ac%:ess to the arbitr.itiun .\n 0\l,nerubtams (out registered in the Hume 11"PrOvII'll"t Curtractor(HIC) Program), Iifion on the HIC Program"a be round at progri I of guantlit) fund under 142,v Othcr iinporiant inforn an be found at�� he Constru0ion stipen-isor License c I information on I Is pI;uIllVj. provide the it lurn .ii It below: t'lllislwd basementdecks or romlil 2. \%litit substantial �lk)rx I ilw-luding garagt- rotai likwr area 1'4. 11 1 flabilable r0uln eutlllt Groij li%ingarealiq. \tIlliber ol'btArMill's NuIllbVir ol,hall'hatili \11nitivro(d"ki parches open I JIV,11,11vAling '),leill 1'110o,�d I\he„t cooling i),tctli - CITY OF SALE.tit PUBLIC PROPERTY DEPARTMENT U 10l1t/r O�OCIYi Wrae Ibv�7bilTfaaR�Suaai VAaAollsRt7Olf'0 iYL f'Lr�ifSf!�F.u,f'L)J67e1e HOMEOWNER LICENSE EXE.MW10N P1eaw Fri.t Dam /_ 20/ 2- Job Locadoe ZZ eVi�' r Home Owner Address - Home Owner Telephone 6 /7- ZY/3 Presaot Mailing Address A9 e The current exemption of"Homeowners"was extended to include owner-occupied dwellings of two Unite or fear and to allow such homeowners to engage an individual for hire who does not possess a lteenso provided that the owner acts as supervisor. DEFINITION OF HOMEOWNER Person(s)who owns a parcel of land on which he/she resides or intends to reaide6 on which that is, or is intended to be6 a one or two family dwa tng. ansched or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two year period shall not be considered a homeowner. Such "Homeowner"shall submit to the Building Official, on a form acceptable to the Building Ofllcial, that he/she be responsible for all such work performed under the Building Permit The undersigned "homeowner"wames responsibility for compliance with the State Building Code and other applicable by-laws and regulations. The undenigned "homeowner"certifies that he/she understands the City of Salem Building Department minimum inspection procedures and requirements and that he/she will comply with said procedures and requirements. HOMEOWNERS SIGNATURE APPROVAL OF SUILDING NSPECTOR ` Sce other side for state code Project 4 1.2-227 McBrie LLc 160 Sylvan Street ...... Telephone:978-646-0097 Danvers,MA 01923 Structural Design &:Sales Fact:978-6464087 wwwmcbriexorn October 03,2012 Mr. Steven Feldmann 22 Ome Street Salem, MA 01970 Steven.feldmanm ap-mail.com RE: Visual Structural Inspection—Bearing Wall Removal 22 Orne Street Salem,MA McBrie, LLC'Project# 12-227 Dear Mr. Feldmann: Per your request, McBrie, LLC performed a visual structural inspection of the above referenced residence on October 1, 2012. The inspection was performed to determine the beam size for removal of a portion of a load bearing wall in the kitchen area. Directions indicated throughout this report assume the building is viewed from Orne Street. EXISTING CONDITIONS The residence consists of a wood framed three story living space structure with a full basement. It appears that a portion of the rear entry room/kitchen may have been a screened in porch or similar based upon McBrie, LLC's observations, however,it is all within the original footprint of the residence. a �` h- Y 3 _4 Rear Elevation Elevation view of wall being removed 12-227 report Page I of 2 1 Project 4 12-227 cBrie LLC 160 Sylvan Street Telephone: 978-646-0097 Danvers, MA 01923 Structural Design& Sales Fax. 978-646-0087 uww.nwbrie.cam a A a .r Right end—new column required Left end—load over foundation wall Based upon McBric,LI—Us observations,it is McBric, LLC's opinion that the wall can be removed and replaced with a beam consisting of 3-1 3/4"x l4"LVLs to meet the 8"M1' edition of the MA building code. The LVI-s should be nailed together per the manufacturers recommendations far a 3-ply beam. The beam should be posted at each end with a 51/4`x 5r14" PSL post. The PSL;posts should beset over spreader plates of LVL 7"x5,25"to spread the load over the existing beam/sill. At the exterior wall.the PSL will bear on the existing sill/bearn that bears on the foundation wall. On. the interior, the PSL will bear on the existing beam which will re-quire a new lallycolumn and footing below it, The lally column should have a minimum 6"x8" Springfield top plate (or similar)and bear on a new 2'-6"x2'-6"x 18" thick footing, This footing can be installed via cutting a hole in the existing basement slab of smaller size, digging out/under the slab and casting the new concrete through the smaller hole. If a well graded gravel soil that can be compacted to over a 2ton/sf capacity exists-as a subgrade, then a 2'x2'xl2"thick footing can be used. The above referenced renovations/framing modifications involve a change in load path down to new column/footing under the supporting'basement beam, This load on a new footing may result in minor settlement and minor cracking in the finishes above,however,it will not be a structural concern due to the conditions observed and our design calculations. Also, it should be noted that this report is based upon a visual inspection of exposed framing members to assess their current condition(s). It does not imply that the framing/structure meets or does not meet any previous or current structural requirements of the Massachusetts State Building Code except.as noted specifically in this report. Please do not hesitate to contact our office if you require additional information. r Sincerely, `ys`Et L- y� p(<AHAM N �- P 51AUCTURAL No.41143 Michael Pe ham, PE FGlS1EPwo�`�Q Structural.:Engineer/Managing Member °" ya �G 12.227 report Page 2 of