Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
28 MOONEY - BUILDING INSPECTION
r3 � `� - 16�f� � 3� zs s s sj The Commonwealth of Massachusetts Board of Building Regulations and Standards CITY OF Massachusetts State Building Code,780 CMR SALEM Revised Mar 1011 Building Permit Application To Construct,Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Vse Only Building Permit Number: Date A lied: Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 '��"�(V Pro erty Alddress: L2 Assessors Map&Parcel Numbers � —1.la is this an acceptedgb street?yet s no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Z `Coning District Proposed Use Lot Area(sq R) Frontage(tl) 1.5 Building Setbacks(ft) a fn Front Yard Side Yards Rear Yard /3 Required Provided Required Provided Required Pro, d . 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: t.8 Sewage Disposal System. rnn Zone: _ Outside Flood Zone? Public❑ Private❑ Check if yes❑ Municipal❑ On site disposal sy7cm ❑'� SECTION 2: PROPERTY OWNERSHIP' p. 2.1 Owner of Record: r' q M Elroy Halfrey V� 1 Name(Print) City,Slate,ZIP No.and StreeL - Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction ❑ Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ Other ❑ Specity: Brief Description of Proposed Work'-: SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: (Labor and Materials) Official Use Only 1.Building $ nci1 ,0b 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ 6.Total Project Cost: $ y Check No._Check Amount: Cash Amount: �� 'y� 0Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) �\'(�� (�i. r��'� � - License Number ` Expiration Date Name{of CSL Holder V List CSL Type(see below) No.and Street •U ) Type Description `-"�U p'.EV� 4uln iy 1 U Unrestricted(Buildings u to 35,000 cu.tL I /1 R Restricted I&2 Famil Dwelling City/Town,State,ZIP M Mason ry r am` a t^ iC k//n rA �`[�/�{Q RC Roofing Covering LU i v WS Window and Siding SF Solid Fuel Burning Appliances I Insulation j Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) k-[C r p— (V Vk V—�'—l.a Y ^�� HIC Registration 6Number Expiration Date HIC Comp y o HIC egistmnt Name qllNo.and Street Qn` Email address .City/Town,State,ZIP Telephone U1U SECTION.6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.g 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. ', Signed Affidavit Attached? Yes..........❑ No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize y', y h4 Syt�PL \ to act on my beh f,i al ers relative to work authorized by this building permit application. 10-6-14 Print Owner s Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this applicat on ' and accurate to the best of my knowledge and understanding. 10-6-14 Print Owner' uthorized Agent's Name(Electronic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. I42A.Other important information on the HIC Program can be found at www.mass.aovioca Information on the Construction Supervisor License can be found at www.mass.govv`d s 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) - Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"maybe substituted for"Total Project Cost" Av CERTIFICATE OF LIABILITY INSURANCE °1101/2013 Y"11ro120V THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 PHONE arc Not: DENVER,CO 80202-5534 E-MAIL Attn:DenvBr.certreglrest@mamh.com,Fax:212.94 ,4381 ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC4 462738-STND-GAWUE-13-14 INSURER A:Evanston Insurance Company 36378 INSURED National Union Fire Insurance Co of PA Vwlnl Solar,Inc. INSURER Is 4931 N 300 W INSURER C;New Hampshire Insurance Company 23841 Prow,UT 84604 INSURERD: INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002368030-06 REVISION NUMBER:O THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADOL SUER POLICY EFF POLICY UP LTR POLICY NUMBER MMIDD)YYYYj IMM(DDNYYYI LIMITS A GENERAL LIABILITY 13PKGN/E00274 11/01/2013 11/01/2014 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY MA 50,000 PREMISES(Ea occurrence) E CLAIMS-MADE M OCCUR VIED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 X POLICY PRO- LOC $ B AUTOMOBILE LIABILITY 9701087 1110112013 1110112014 COMBINED DrtSINGLE LIMITMe $ 1,000,000 B X ANY AUTO 9701008 11/012013 11101/2014 BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ X HIRED AUTOS X NOITNOSNMED PPROPE��DAMAGE E $ A UMBRELLALUU3 X BUR 13EFXWED0088 11101/2013 111012014 EACH OCCURRENCE $ 10,000,000 X EXCESS LIAR CLAIMS-MADE AGGREGATE Is 10,000,000 DED RETENTION$ $ C WORKERS COMPENSATION 029342334; 029342335 111012013 1110112014 X I 1A'C STATU- I OTH- AND EMPLOYERS'LIAMUITYER G ANY PROPRIETORIPARTNEWEXECUTIVE YIN 029342336; 029342337 111012013 i1101IZ014 E.L.EACH ACCIDENT $ 1,000,000 C OFFICEWMEMBER EXCLUDED? Efl NIA (Mandatory in NMI 029342338 11/012013 11MI2014 E.L.DISEASE-EA EMPLOYE $ 1,000'000 If yes,desaioe under - 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY UMIT $ A Enors&Omissions& 13PKGW00029 11/012013 lliOl/2014 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (Attach ACORD 101,Addidoned Rerrurks Schedule,N mare seam Is required) e Certificate Holder and others as defined in the written agreement are included as additional insured where required by wdtlen contract with respect to General Uabilily.This insurance is primary and Ion- nbibutory over any e)dsbng insurance anti limited to liability arising out of the operations of the named insured and where required by written contract.Waiver of subrogation is applicable where required by written tract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZE°REPRESENTATIVE of Man:h USA Inc. Kathleen M.Parsloe '3'r- fig"/sL ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 26(2010105) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents n�_ c Office of investigations I Congress Street, Suite 100 -:v Boston, MA 02114-2017 Y www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/lndividual): Vivint Solar Developer LLC Address: 4931 North 300 West Citv/StateZi Provo _UT 84604 Phone#: 801-704-9389 Are you an employer?Check the appropriate box: Type of project(required): 1. I am a employer with 10 4. ❑ I am a general contractor and I employees(full and/or part-time). have hired the sub-contractors 6. ❑New construction 2.❑ I am a sole proprietor or partner- listed on the attached.sheet. 7. ❑ Remodeling shipand have no employees I`hese sub-conumcuxs have 8. ❑ Demolition working for me in any capacity. employees and have workers' [No workers' comp. insurance comp. insurance.t 9. ❑ Building addition required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing a]I work officers have exercised their I LEI Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL P 12.❑ Roof repairs insurance required.] t c. 152, §I(4),and we have no employees. [No workers' 13.0 Other ^_- comp. insurance required.] `Any applicant that checks box#1 must also till out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating.such- tcontractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number I am an employer that is providing workers'compensation insurancefor my employees. Below is the policy and job site information. Insurance Company Name:— New Hampshire Insurance Company,__ Policy#or Self-ins. Lic. #: 029342228 Expiration Date: 11/01/14 Job Site Address:_._ �I�_l1L h/1 l Q _ _City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under pails I ul pena/ite.of perjury 1 i the information provided above is true and correct tiinature: Phone =: 01-704-9389 Official use only. Do not write in this area,to be completed by city or town official. City or Town: _Permit/License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other_ Contact Person: Phone#: i.l vaaacc vi %,vu3uuae,t aitu asuauxc�� aac�uxatxixu a 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/512016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, UT 84604 Update Address and return card.Mark reason for change. SCA 1 C 20M-05/11 Address Renewal Employment Lost Card 1�1 Massachusetts -Department of Public safety Board of Building Regulations and Standards Construction Supern'isor License: CS-045254 SAMES R SHERMA i i. 6 Fox Hollow Drife T!! _ SAUGUS MA 01506 =� a Expiration 08/28/2078 Commissioner 4931 North 300 West Structural Group Provo,UT84604 P: (801)234.7050 Scott E. Wyssling, PE Head of Structural Engineering scott.wyssling@vivintsolar.com September 29,2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Halfrey Residence 28 Mooney Road, Salem MA S-3998163 10.455 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a.Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 8 dimensional lumber at 16" on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 41 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure "B", Zone 2 per (ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. " Page 2 of 2 B. Loading Criteria 10 PSF=Dead Load roofing/framing 40 PSF=Live Load(around snow load) 5 PSF=Dead Load solar panels/mountina hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading Criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 '/2", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2 with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four(4) rafter spaces or 64"o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. ery truly yours, OF E T Y Scott E. Wy ling, cw MA License No. 0 50 9�F FGiSTEP� FSSIONAL F---- --- - -- --- ---- ---- ---- - - JUNCTION BOX ATTACHED TO I U o ARRAY USING ECO HARDWARE TO I m KEEP JUNCTION BOX OFF ROOF o� E z Zvi —0 NO U I I ti a U I I 110'OF 1"PVC CONOUIT 4 1 f FROM JUNCTION BOX TO ELEC PANEL ) I I � n 0 I I •e m PV INTERCONNECTION POINT, J LOCKABLE DISCONNECT SWITCH, I ANSI METER LOCATION, 8 UTILITY METER LOCATION I I a C m o n g ^ a Q f Q U I 12 m Z LL Z N J Z a a ; I I z i f o PV SYSTEM SIZE: SHEET NAME: (41)Vin9li EnerpY YL255-291,MODULES WITH A 10.455 kW DC Enphase M215-60-2LL-S2.ZC MICRO-INVERTER Z MOUNTED ON THE BACK OF EACH MODULE I W J -------- ---- ---- ---- -- ---�-- - � � a SHEET S NUMBER: 28 Mooney Rd , Salem MA 01970 1PV SYSTEM SITE PLAN 4 SCALE: 3/32"= T-0" > a � m COMP.SHINGLE o� (�m�m Roof Section 5 m Roof Azimuth:109 -i Roof Tilt:41 COMP.SHINGLE z n Z N COMP.SHINGLE J O U ` UQ ,V 2 J Roof Section 1 Roof Azimuth:199 V CIRCUIT#1: Roof T,It:41 A MODULES i U: Roof Section 2 RoofAarnW1'.109 v Roof T IL 41 Roof Section 4 RoofPvm.M:,09 •G , RmfTit 41 COMP.SHINGLE------,,,., V CIRCUIT#2: TIE INTO METER# 12 MODULES 96580892 `! m g m $o m N K U F ¢ m M1 m COMP.SHINGLE w� w m zzF 3 m m m z oz V CIRCUIT#3: SHEET 12 MODULES NAME: u- Z O ()f n. Roof Section 3 SHEET RoofA.m :199 NUMBER: Roo1Te:41 PV SYSTEM ROOF PLAN o N SCALE: 3/32"= T-0" 7 a MOUNTING SEALING CLAMP JAINLESS U PV3.0 DETAIL WASHERc m LOWER SUPPORTN o m Q�0 z 2El PV MODULES, TYP. MOUNT mo OF COMP SHINGLE ROOF, FLASHINGFa L PARALLEL TO ROOF PLANE21/2" MIN5115"P x 4 1/PV ARRAY TYP. ELEVATION STEEL LAG MINIMUM NOT TO SCALE TORQUE=13±2 ft-Ibs r^� 1 CLAMP ATTACHMENT J) NOT TO SCALE C � •o a CLAMP+ ATTACHMENT CANTELEVER U4 OR LESS o0 COUPLING J L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. e PERMITTED COUPLING CLAMP+ CLAMP CLAMP h a ATTACHMENT SPACING z m COUPLING PHOTOVOLTAIC MODULE m K K z z m W Z h z a ug z_ _z 2 o SHEET NAME: L=PORTRAIT t7F- GO CLAMP SPACING z Q F LLI ECO M m L=LANDSCAPE COMPATMODULE PV PV SYSTEM MOUNTING DETAIL SHEET NUMBER:' CLAMP SPACING MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 NOT TO SCALE d Inverter Ratings(Guide Section 4) 0 Conduit and Conductor Schedule Inverter 45 Were caGouw a wit Farm el 5npnoae mzlsag-zu-szxzc MODULE DETAIL Max GC Vmi Tag Downfallen re ofcondaemro Cendmt Type Condon size Max Pewer III 40°C 215 Wetly t Emphasis engage cobs-TXWN3 12AWG Q Cmd N/A-Free qlr A\ cc moment PC Vrai 240 Volts Y/ Yingli Energy VL255-29b Mez AC Cunent 0.9 gmps I Bare Copper Ground(EGCIGEC) agWGt N/p-Free Ab NIA-Free plr U SOLAR MODULE Max 01 Rating zo Amps 2 Ti 10 AWG 9 Pvc a-r /�� Max Number of PanelslCowit 1] 2 THWN-2-Ground BAWG I PVC ti'-1' Wce NOTES FOR INVERTER CIRCUITS(Guide Section 8 antl ii 3 THWN-2 BAWG J PVC V, � _3_THWNvz-Grountl 8AWG I PJCNBom 1.)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS PV Module Ratings Q STC(Guide Section 5) `o Emphasis M21&6D-2LL-S2x-ZC SWITCH MEETTHE REQUIREMENTS? Model MakelModel Yingll Energy VL25S296 2 MICRO-INVERTER AT YES NO XNA f m~Max Power-Point Cunent(Imp) B.J2 Amps Z EACH MODULE,ATTACHED Z)IF GENERATION METER REQUIRED,DOES THIS METER Max Power-Point Voltage(Vmp) 306 Volb °rqp WITH ECO HARDWARE SOCKET MEET THE REQUIREMENTS? U OpenLiuit Volbge(Vad 38J Volta YES NO X NA Shod-Circuit Current fact 8.88 Amps 3.)SIZE PHOTOVOLTAIC POWER SOURCE(DC)CONDUCTORS Max Series Fuse(OCPD) 15 Amps F BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Maximum Power at STC(Pmax) 253 Watts Co zi MICROINVERTER CONNECTION _ RATING AT DISCONNECT maximum System Voltage 1000(IECy900(UL) = j TO ENGAGE TRUNK CABLE 4.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Voc Temperature CoeRcient -0.32 %PC TO INVERTER OCPD AMPERE RATING(See Guide Section 9f V 5.)TOTALOF 3 INVERTER OCPO(s).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide Section 6 and 8 and Apparel Di PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN T)Lowest expected ambient temperature based on ASHRAE minimum mean extreme #fi BARE CU GROUND NEC 690.64(8)(2)(a)? XYES NO dry bulb temperature for ASHRAE location most longer to installation location: -19°C {' T (GROUNDINGARRAY) Signs(Sea Guide$BCII007) 2r,pegrture for Elocatt temperature based on ASHRAE highest39-C 2%dry bulb temperature br ASHRAE location most similar to Installation location 39°C a r, Sign for Inverter OCPD and AC Disconnect: 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47°C in the tea+ United States(Palm Springs,CA is 44.1°CL For less than 9 cument-darrying conductors L+ Solar PV System AC Point of Connection in mor.mounted sunlit conduit at least os°above hour and using the outdoor design ACOuiput Cunent 36.900000 Amps temperature of 47°C or less(all of United States). • Nominal AC Voltage x4ol Volts a.)12 AWG,90°C conductors are generally determine for modules with Ise of 768 Amps < PV CIRCUIT 1: 17MODULES/PARALLEL HIS PANEL FEDBYMULTIPLESOURCE9 or less when pmtectedbyal2-Amp or smaller fuse. (UTIUTYANOSOIAR) b.)10 AWG 90°C condudom are generally acceptable for modules wit lsc of 9.6 Amps N or less when protectedb a 1 SnAorp or smaller fuse. •0 on 1] • • • O O 1 NOTE: NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY •� E 1.o ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR in .r • • • .r she i on I ENVOY BOX PV CIRCUIT 2: 12 MODULES/PARALLEL 8 m P g m ed Q • • • O O I I M a U 1 i MURRAY Z m Q m COMBINER > j s on s • • • �. �, E 1.0 i PANEL 125A/240V I. , to I C od LWO04NR SIEMENS J J w m \yO PO OR EQUIVALENT 60AI240V SIEMENS Q a 3 -- --- \Gs G2 1 UNFUSED 6ON240V ad h J NEMA3 FUSED NEMA3 ? ? , o PV CIRCUIT 3: 12 MODULES/PARALLEL �\f��6L SREC/ANSI LNF222R OR GF222R OR EXISTING METER EQUIVALENT EQUIVALENT ENTRANCE NAME 0 I q\P C 2� O CONDUCTORS 12 • • • O 0 1 \�P RATED:200A Z 1 \\ 15A 81L`/A1 J 0 I \ ISa 1�/1 SUPPLY-SIDE A Q J` • • • ,/� E 1.0 \ 50A SOLAR TAP O NEc1as 121A) SHEET NUMBER: __ _______ 240V/2 \\ MILBANK VISIBLE/LOCKABLE I pANEL00A O JUNCTION BOX 2 \\ 3 100A OR 3 'KNIFE'A/C g 3 y WITH IRREVERSIBLE \ EQUIVALENT DISCONNECT TO EXISTING NEC 2014 Compliant GROUND SPLICE E 1.0 \ E 1.0 U5934-XL-BLG E 1.0 E 1.0 E 1.0 LOAD-CENTER LLI Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Elroy Halfrey Project Address: 28 Mooney Rd,Salem MA A.System Description: The array consists of a 10.455 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(41) 255-watt modules and (41)215-watt micro-inverters,mounted on the back of each PV module.The array includes(3)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecobbrium Solar. B.Site Design Temperature: (From Boston Logan INTL ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12 V) C.Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecolibrium Solar b.Product Name: Ecorail c.Total Weight of PV Modules and mounting hardware: 1726.4 Ibs d.Total number of attachment points: 83 e.Weight per attachment point: 20.8 Ibs f Maximum spacing between attachment points: *See attached engineering calcs g.Total surface area of PV array: 720.94 square feet h. Array pounds per square foot: 2.39 Ibs square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (12)modules,(23)attachments 21.96 pounds -Roof section 2: (12)modules,(23)attachments 21.96 pounds per square foot -Roof section 3: (6)modules,(13)attachments 19.43 pounds per square foot -Roof section 4: (8)modules,(16)attachments 21.05 pounds per square foot -Roof section 5: (3)modules,(8)attachments 15.79 pounds per square foot vivint. S(7',a r 3. Electrical Components: A.Module (UL 1703 Listed) Qty Yingh Energy YL255P-29b 41 modules Module Specs Pmax-nominal maximum power at STC - 255 warts Vmp-rated voltage at maximum power - 30 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.49 amps Isc-rate short circuit current - 9.01 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-2LL-S22 41 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 3 PV circuit 1 - 17 modules/inverters (20)amp breaker PV circuit 2 - 12 modules/inverters (15)amp breaker PV circuit 3 - 12 modules/inverters (15)amp breaker 2011 NEC Article 705.60(B) vivint. Sul a D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 15.3 amps Continuous current adjustment factor 125% 2011 NEC Article 705.60(3) PV circuit continuous current rating 19.125 amps 2.Overcurrent protection device rating PV circuit continuous current rating 19.125 amps Next standard size fuse/breaker to protect conductors 20 amp breaker Use 20 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (10112°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Arnde 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Article 705.60(B) Adjusted PV circuit continuous current 26.9 amps c.PV Circuit current adjustment for conduit£dt Number of current-carrying conductors 9 conductors Conduit fill derate factor 70% 2011 NEC Article 705.60(B) Final Adjusted PV circuit continuous current 38.4 amps Total derated ampacity for PV circuit 38.4 amps Conductors (tag2 on 1-line)must be rated for a minimum of 38.4 amps THWN-2(90°C) #10AWG conductor is rated for 40 amps (Use#10AWG or larger) 2011 NEC Article 705.60(B) 4.Voltage drop(keep below 3%total) 2 parts- 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors(from j-box to point of interconnection) 1.Mirco-inverter voltage drop: 0.31% The largest number of micro-inverters in a row in the entire array is 8 inCircuit 1.According to manufacturers specifications this equals a voltage drop of 0.31 %. 2.AC conductor voltage drop: = I x R x D (-240 x 100 to convert to percent) _ (Nominal current of largest circuit)x(Resistance of#1 OAWG copper)x(Total wire run) _(Circuit 1 nominal current is 15.3 amps)x(0.00126Q)x(220) -(240 volts)x(100) 1.76% Total system voltage drop: 2 07% vivin#. sol,4,r EcolibriumSolar Customer Info Name: Email: Phone: Projectlnfo Identifier: 12073 Street Address Line 1: 28 Mooney Rd Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Yingli Solar Module Model: YL255P-29b Module Quantity:41 Array Size (DC watts): 10455.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight:40.8 Ibs Module Length: 65.0 in Module Width: 39.0 in Basic Wind Speed: 110.0 mph Ground Snow Load:40.0 psf Seismic:0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load-Upward:820 Ibf Lag Bolt Design Load- Lateral: 300 Ibf EcoX Design Load -Downward:493 Ibf EcoX Design Load- Upward: 568 Ibf EcoX Design Load- Downslope: 353 Ibf EcoX Design Load -Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 Plane Calculations (ASCE 7-10): R1 EcolibriumSolar Roof Type: Composition Shingle Average Roof Height: 20.0 ft Least Horizontal Dimension: 30.0 ft Roof Slope: 41.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.53 0.53 0.53 Roof Snow Load 17.8 17.8 17.8 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Net Design Wind Pressure Downforce 19.4 19.4 19.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 j Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Design Wind Pressure Downforce 19.4 19.4 19.4 psf 71 ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 17.8 17.8 17.8 psf Downslope:Load Combination 3 10.3 10.3 10.3 psf Down: Load Combination 3 11.9 11.9 11.9 psf Down:Load Combination 5 13.4 13.4 13.4 psf Down: Load Combination 6a 18.1 18.1 18.1 psf Up: Load Combination 7 -11.4 -13.5 -13.5 psf Down Max 18.1 18.1 18.1 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 77.3 77.3 77.3 in Max Spacing Between Attachments With RafterfTruss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 25.8 25.8 25.8 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 59.8 59.8 59.8 in Max Spacing Between Attachments With Rafterrrruss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 19.9 19.9 19.9 in Layout EcolibriumSolar i �I I I Skirt o Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. Plane Calculations (ASCE 7-10): R2 EcolibriumSolar Roof Type: Composition Shingle Average Roof Height: 20.0 ft Least Horizontal Dimension: 30.0 ft Roof Slope: 41.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.53 0.53 0.53 Roof Snow Load 17.8 17.8 17.8 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Net Design Wind Pressure Downforce 19.4 19.4 19.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Design Wind Pressure Downforce 19.4 19.4 19.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 17.8 17.8 17.8 psf Downslope: Load Combination 3 10.3 10.3 10.3 psf Down:Load Combination 3 11.9 11.9 11.9 psf Down: Load Combination 5 13.4 13.4 13.4 psf Down:Load Combination 6a 18.1 18.1 18.1 psf Up: Load Combination 7 -11 A -13.5 -13.5 psf Down Max 18.1 18.1 18.1 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 77.3 77.3 77.3 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 25.8 25.8 25.8 in Spacing Results Portrait P 9 (Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 59.8 59.8 59.8 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 19.9 19.9 19.9 in Layout EcolibriumSolar ri i r r Skirt e Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 4 Bonding Jumper maximum allowable overhang. Plane Calculations (ASCE 7-10): R3 EcolibriumSolar Roof Type: Composition Shingle Average Roof Height: 20.0 ft Least Horizontal Dimension: 22.5 ft Roof Slope: 41.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.53 0.53 0.53 Roof Snow Load 17.8 17.8 17.8 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Net Design Wind Pressure Downforce 19.4 19.4 19.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Design Wind Pressure Downforce 19.4 19.4 19.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 17.8 17.8 17.8 psf Downslope: Load Combination 3 10.3 10.3 10.3 psf Down:Load Combination 3 11.9 11.9 11.9 1 psf Down: Load Combination 5 13.4 13.4 13.4 psf Down:Load Combination 6a 18.1 18.1 18.1 psf Up: Load Combination 7 -11.4 -13.5 -13.5 psf Down Max 18.1 18.1 18.1 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 77.3 77.3 77.3 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 25.8 25.8 25.8 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 59.8 59.8 59.8 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 19.9 19.9 19.9 in Layout EcolibriumSolar r � Skirt e Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. Plane Calculations (ASCE 7-10): R4 Roof Type: Composition Shingle EcolibriumSolar Average Roof Height: 41.0 ft Least Horizontal Dimension: 17.0 ft Roof Slope: 41.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations E Interior Edge Corner Unit Load 33.6 33.6 33.6 psf 0.53 0.53 0.53 d178 17.8 17.8 psf Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Net Design Wind Pressure Downforce 19.4 19.4 19.4 psf Adjustment Factor for Height and Exposure Category 1.12 1.12 1.12 Design Wind Pressure Uplift -27.2 psf Design Wind Pressure Downforce 21.7 21.7 21.7 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 17.8 17.8 17.8 psf Downslope: Load Combination 3 10.3 10.3 10.3 psf Down:Load Combination 3 11.9 11.9 11.9 psf Down:Load Combination 5 14.8 14.8 14.8 psf Down: Load Combination 6a 19.1 19.1 19.1 psf Up:Load Combination 7 -12.9 -15.3 -15.3 psf Down Max 19.1 19.1 19.1 psf Spacing Results(Landscape) kDescription Interior Edge Corner Unit e Spacing Between Attachments75.1 75.1 75.1 in Between Attachments With Rafterliruss Spacing of 16.0 in 64.0 64.0 64.0 in r from Attachment to Perimeter of PV Array 25.0 25.0 25.0 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 57.1 57.1 57.1 in Max Spacing Between Attachments With Rafterfrruss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 19.0 19.0 19.0 in Layout EcolibriumSolar m Skirt e Coupling 0 Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. Plane Calculations (ASCE 7-10): R5 Roof Type: Composition Shingle ECDlibfiUmSDlar Average Roof Height: 20.0 ft Least Horizontal Dimension: 19.0 ft Roof Slope: 41.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Flat Roof Snow Load Interior Edge Corner Unit 33.6 33.6 33.6 psf Slope Factor 0.53 0.53 0.53 Roof Snow Load Wind Pressure Calculations 17.8 17.8 17.8 psf Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Net Design Wind Pressure Downforce 19.4 19.4 19.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Design Wind Pressure Downforce 19.4 19.4 19.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load Snow Load 2.3 2.3 2.3 psf 17.8 17.8 17.8 psf Downslope: Load Combination 3 10.3 10.3 10.3 psf Down:Load Combination 3 11.9 11.9 11.9 psf Down:Load Combination 5 13.4 13.4 13.4 psf Down:Load Combination 6a 18.1 18.1 18.1 psf Up: Load Combination 7 -11.4 -13.5 -13.5 psf Down Max 18.1 18.1 18.1 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 77.3 77.3 77.3 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 25.8 25.8 25.8 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 59.8 59.8 59.8 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 19.9 19.9 19.9 in Layout EcolibriumSolar #I f i i i M Skirt o Coupling O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. • . Distributed Weight (All Planes) EcolibriumSolar In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 1673 Ibs Weight of Mounting System: 166 Ibs Total System Weight: 1839 Ibs Total Array Area: 722 ft2 Distributed Weight: 2.55 psf Number of Attachments: 83 Weight per Attachment Point:22 Ibs Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 83 ECO-001_102 EcoX Coupling Assembly 56 ECO-001_105B EcoX Landscape Skirt Kit 20 ECO-001_105A EcoX Portrait Skirt Kit 2 ECO-001 103 EcoX Composition Attachment Kit 83 ECO-001_109 EcoX Electrical Assembly 5 ECO-001_106 EcoX Bonding Jumper Assembly 17 ECO-001_104 EcoX Inverter Bracket Assembly 41 ECO-001_338 EcoX Connector Bracket 41