Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
74 MOFFATT RD - BUILDING INSPECTION
,ram The Commonwealth of Massachusetts �1 Board of Building Regulations and Standards CITY OF L Massachusetts State Building Code, 780 CMR SALEM Mar `fF'✓) Revised Mar 2011 Building Permit Application To Construct, Repair, Renovate Or De lish a One- or Two-Family Dwelling This Section For Official U Only ! Building Permit Number: Date Ap ied: /�. Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.�ropert A�W: /2e'e 1.2 Assessors Map&Parcel Numbers 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(11) 1.5 Building Setbacks(it) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: — Outside Flood Zone? Municipal❑ On site disposal system ❑ Check ifyes❑ SECTION 2: PROPERTY OWNERSHIP[ 2.1 Owner=d: / ECiN tGlsf Name(Print) City,State,ZIP 74 /A ✓2cl I 7114>_3�5- No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units_ I Other &'Ipecify: PV St&G Brief Description of Proposed Work2: Z;1,61* / 7 9- Py Sour SECTION 4:ESTIMATED CONSTRUCTION COSTS Estimated Costs: Item Labor and Materials) Official Use Only 1.Building $ Z 000 _ 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ 2� C -p ❑ Standard City/Town Application Fee ❑Total Project Cost (Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: / (� 5.Mechanical (Fire $ Suppression) Total All Fees: $ 7 �S SO Check No. Check Amount: Cash Amount: 6. Total Project Cost: $Z ❑Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) /u 'y"Cv License Number E prmnon Date Name of CSL AoIder / List CSL Type(see below) � (/ "e Type Description D 2, 703 U Unrestricted(Buildings up to 35,000 cu.ft. R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding / SF Solid Fuel Burning Appliances / `l40/-574'6(pb 7 �OCW ✓7 �k�ji/,bT/t/r.�OJst I Insulation Telephone Email address D De m . ifion 5,r..22'�Registered Home Improvement Contractor(HIC) / >OZ 7 c/ /D 5 (LOa(I pQGs70S�fS !!57614r— HIC Registration Number xp anon Date HIC Camp ny Na orIVC Regis ant Name No. d ct Email address Cit /Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes .......... ❑ No........... ❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIESS FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize 16t hb Al- to (abet on my behalf, iino all 'matters relative to work authorized building permit application. `L-M-910 -^�f /f /3 Frifvf Owner's Name(Electronic Signature) Date SECTION 7b: OWNERt OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of myJwiowledge and understanding. Print Owne 's or Authorized Ag (Ele tc tore / Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.eov/oca Information on the Construction Supervisor License can be found at www.mass.eov/dos 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of halfibaths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" t�D'.q..11. SOLAR 89F Washington Avenue Natick, MA 01760 ph (508)545-0989 fax (508)545-1141 roofdiagnostics.com/solar Attention: Inspectional Services With this letter I, Jean Dibble authorize you to recognize Joseph Wyld Chirico of Roof Diagnostics Solar of MA, LLC, (CSL# 93115 HIC# 170279) as my Agent, and acting on my behalf may apply and sign for permits pertaining to my SUNRUN PV Solar System installation project located at 74 Moffatt Rd, Salem, MA 01970 . By my signature, I recognize and approve the construction of which the plans are submitted, and willfully accept the responsibility as owner/builder of this project. Owner Signature 02/11/2013 D to Josep yld-Chirico - Authorized Agent z �i i3 Date 1 The Commonwealth of Massachusetts Department of IndustrialAccidents Office of Investigations 600 Washington Street Boston, MA 02111 www.massgov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Roof Diagnostics Solar of MA LLC Address: 89 F Washington Ave City/State/Zip: Natick,MA 01760 - Phone#: 508-545-0989 Are an employer?Check the appropriate box: Type of project(required): 1. I art a employer with 4. ❑ I am a general contractor and I �� 6. ❑ New construction employees(full and/or part-time).* _ have hired the sub-contractors 2. I am a sole proprietor or artner- listed on the attached sheet. 7. ❑ Remodeling ❑ P P P ship and have no employees These sub-contractors have 8, ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.: required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12 ❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no � employees. [No workers' 13.E/Other PV `!544� comp. insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. *Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. l am an employer that is providing workers'compensation insurance for ney employees. Below is the policy and job site information. Insurance Company Name:The Hamilton Group/Continental Indem.Co. Policy#or Self-ins. Liic. #: 468185310103 Expiration Date: 10/5/13 Job Site Address:- 7 ' /y/d 1 ' T/ /C,n City/State/Zip:61gkol t Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties ofperjury that the information provided above is true and correct. Signal e / r(Z Date Phone#:508-545-0989 Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector S. Plumbing Inspector 6.Other Contact Person: Phone#: ` A'Rom® CERTIFICATE OF LIABILITY INSURANCE 2/13/2013"r"' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endomement(s). PRODUCER CONTACT NAME: The Hamilton Group, LLC PH ONE FAX MV 3 Wing Drive E41AIL - -221)2 NC No: - - Cedar Knolls NJ 07927 ADDRESS: PRODUCER CUSTOMERIDd:ROOFD-3 INSURERS)AFFORDING COVERAGE NAICN INSURED INSURERA:Selective Way Ins I Roof Diagnostics Solar of INSURFRB:Slective Ins Cc of the S. East Mass LLC 89F Washington Avenue INSURER C:Continental Indemnity Com an Natick MA 01760 INSURERD: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:723267328 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR NSR1 TYPE OF INSURANCE A POLICYNUMBER MWDDPOLICYEFF MMMDY"P LIMITS LTR A GENERAL LIABILITY 52000721-00 10/3/2012 10/3/2013 EACH OCCURRENCE $1,000,000 DAMAGE TO RENTED 100,000 X COMMERCIAL GENERAL LIABILITY PREMISES Ea occurrence $ CLAIMS-MADE E] OCCUR MED EXP(Any onePerson) $10,000 PERSONAL S ADV INJURY $1,000,000 GENERAL AGGREGATE $3,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMPIOP AGG $3,000,000 POLICY r7PRO- LOC $ B AUTOMOBILE LIABILITY A9093006 10/25/2012 10/3/2013 COMBINED SINGLE LIMIT $1,000,000 (Ea accident) X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED AUTOS BODILY INJURY(Per ouldent) $ SCHEDULED AUTOS PROPERTY DAMAGE HIRED AUTOS (Per accident) $ NON-OWNED AUTOS $ $ A X UMBRELLA LIAB X OCCUR S2000721-00 10/3/2012 10/3/2013 EACH OCCURRENCE $1,000,000 EXCESS LIAB CLAIMSMADE AGGREGATE $1,000,000 DEDUCTIBLE $ RETENTION $ $ C WORKERS COMPENSATION 468185310104 10/5/2012 10/5/2013 WCSTAT' OTH- AND EMPLOYERS'LIABILITY S ER ANY PROPRIETORPARTNERIEXECUTIVE YIN E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED' NIA (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 DESCRI TIONoribe antler EL.DISEASE-POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS below DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,If more space Is required) This certificate does not afford coverage for additional insureds. The certificate is only evidence of insurance coverage for the named insured. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. City of Salem 120 Washington Street Salem MA 01970 AUTHORIZED REPRESENTATIVE 01988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009109) The ACORD name and logo are registered marks of ACORD Board of Buildin-- Regulations and Standards Construction Supervisor License License: CS 93115 JOSS#'9 M WYLDCHIRICO 39,DRAPER WAY ATTLEBORO, MA 02703 %•L �y�� Expiration: 5/142013 C'unnnisiioiu•' ' TrK: 10770 ✓�e 'tpommtoouuoealui a�✓f�aoeat�aae�ta i. Office of Consumer Affairs&flusioess Reguletioo j OME IMPROVEMENT CONTRACTOR n Registration`�'U 0279 Type � 'i �Ir Expiration 10t5/2013 Supplement 1 '� ROOF DIAGNOSTICS SOLAR OFI�MASS, LLC. t! 1 I JOSEPH WYLD-CHI 0 P+i it 89 WASHINGTON Y NATICK, MA 01760 Undersecretary 4 its 1� s ©SHA 36-600946031 This card acknowledges that the mciplenl has successfully completed a 30-hour Occupational Safety and Health Training Course in Construction Safety and Health 10SEP_H VV LD-.CHIRICO Michael Mlllsap 4/22/2011 {(miner name-print or type) (Course end dale) e Tom Petersen Architects 0 Planners Mr. Thomas J. St. Pierce,Inspectional Services Director April 27,2012 City of Salem Inspectional Services 120 Washington Street, 3 d floor Salem, MA 01970 Re: Solar Panel Installation Dibble Residence 74 Moffatt Road Salem,MA 01970 Hi Tom, I've reviewed the proposed solar panel installation at this location to evaluate the existing roof structure and the connection of the panels to the roof. Criteria: Applicable codes: 8'h Edition Residential Code(2009 International Residential Code with Massachusetts Amendments) 2001 Wood Frame Construction Manual Design roof load: 40 psf live load, 15 psf dead load, 55 psf total load Design wind load: 110 mph, 35 psf My findings are as follows. 1. The new solar panels will imply an additional dead load of 3 psf. The existing roof structure (wood roof trusses @ 16"o.c.,with 2x4 chords and rafters,+/- 1 P-8" span) is sufficient to bear this additional load. 2. The solar panels are attached to the roof with the SolarMount-I rack system by UNIRAC. The rack system, roof connections and connection spacing are rated for 110 mph. This project requires the larger Solar Mount I-2.5 beam(2.5"high)and spacing of flange foot connection to roof at 48" o.c. maximum.Flange footing connections to the rail are not required to be staggered. The flange foot connections to the roof are 3/8" diameter x 4" long lag bolts. I therefore certify that this installation complies with the applicable codes and design loads mentioned above and is acceptable for approval. Please let me know if you have any questions on this information. Thanks! ��%BD ARC Sin ely yours, `gp'�0�p. PFr�pN�0 a No.31821 z °sf HOWELL, Tom Petersen o NJ a Cc:' helcy Peg ler,Roof Diagnostics 'ov 0 ^8gr 6 Country Lane•Howell,New Jersey 07731 •Telephone 732-730-1763,Fax 732-730-1783 0 LLLLL ELL LLEi t,±LLLLLLLL""��,LLLLLLL- 1ELL L LLLtL L I -.,; Pictometry aap 113 ROOF w e> INVERTER#I: AZIMUTH: 201 PITCH:22 JS7 L6 255W POWER ONE 4000 ] F 28 PANELS 4 STRINGS OF l TOTAL STSTEM SIZE c.lZOk■� 3, 3_ 44MODULES ^255w PER MODULELE El 1� ROOF DIAGNOSTIC5 SOLAR AND ELECTRIC. LLC r ;• 51TE MAP JEAN DIBBLE I aY,RA5 Revisiox ;,v eevma:�o�e6 o•saa• LG 255SIC—G2 14 MOFFATT ROAD PANELS-255w SALEM. MA 01910 DATE:21 APRIL 20I2 DWG NO.: tic Roof Mounted PV Array-7.140 kW DC TOTALS: PV system specifications Modules 28 LG 255w NEC 690.53 4 String of 7—V DC:260.4 Rated operating current:34.54 4#6THHN Vmp:30.1 Rated operating voltage:240V 2 Hot/1 Nuetral+1 To Utility Im 7 8 A Max.system voltage:312.48 equip ground National Grid PP Rated short-circuit current35A In 1"PVC VOC:312.48 Polarity of grounded conductor:Ungrounded Max.Voltage:210V Utility Exterior Interior M Meter mR 3 combiner Box 5-#8THHN/ GE60A 4#8THHN co 3 strings Posed 2 Hot,2 Neutral 4#8 THHN Disconnect AC 2 Hot/1 Nuetral+1 @15A +1 equip Ground DC Disconnect 2 Hot/1 Neutral equip ground In''/ PVC 40 amp 600V 1 equip ground In PVC located on In''/PVC 28 LG 255w Inverter Supply side modules connection DC Inverter AC 4 String of 7, disconnect PONE 6000 disconnect DC AC ____ __ _ ______ __ _ _ _ ----- --- -------------- DC groundingelectrode conductor- #6 THHN LG Solar Panels: 3KW-HR Maximum power at STC:255 Centron GPRS 1 Existing MPP voltage:29.8 Smartmeter L Main MPP current 8.23 Single Phase Building distribution Open circuit voltage:37.0 125A Grounding panel Short circuit current:8.67 w/ wireless Electrode Main:200 A Module efficiency: 15.2 connection Maximum system voltage:600 V Maximum series Pose rating:20 A Power tolerance:0.-+3% NEC 690.8 Continuous= 125% Ambient Temp=83+40= 123° F factor of.76 NEC 690.7— Based on-12°F.the correction factor is 1.20 x 37.0 VOC X 15=312.48 Series Isc=8.67A x 125%10.4A/.76=13.7 Using#8THHN(194°F) Drawing: RD-SK- 246 Roof Diagnostics, Inc Name: Jean Dibble All work to comply with NEC2011. All equipment is UL listed for use. One Line Diagram Address: 74 Moffatt Rd Conduit For DC will be PVC outside and Metal insideH, wherever necessary. Salem Ma 01970 Ambient record low:-12 degrees F. Solar Installation Phone: 978 744 7315 Ambient record low high:83 degrees F CV7 LG Life's Good / � 1 Mono TM LG245S1C-G2 Power rom th:Z'ndean, renewable, affo dable.T}a's isIthe dream of solar energy, �a LG is Taking it real with the introduction O, f the Mono:X'O soar module. Loaded rith fea tbres for easy installation, use a n�nance,the Mono X`" modules pro de decades of clean, renewable and Ay a ordable energy for residential,commercial n u.'I fy applications. LG' ong and successful record in the e ctronics industry provides assurance that oos ng LG's state-of-the-art solar modules is an investment in superior standards of design, manufacture and support. World4 7st qOW fund.ora CULusCC ,.mar f Th 1,.. r!,. m Uc.lr:nc_ D..•:::tomb for Dur:,b.hi Customers iesl assured of cutting-edge Or LG solar modules are designed v:ilh slim and technology and depondabiliry,when they sec the r 8 durable ghss to be light in weight while also being Ss LG logo on every cell.The LG logo reflects the able to withstand heavy loads up to 5400 Pa. high standards that have guided LG for more than SD years. pm'iiw to ,• • io. +3% LG provides rigorous quality testing to solar Aev c". .a t—dtln" L b o modules to assure euslomn s of the stated pov:er LG's laboratory has earned the stamp of approval outputs of all modules,v.1th a positivo nominal Test/ from both TUV Rheinland and Underwrilers ""^'"• tolerance starting at O%. Lab. LaL•oratodes as an official testing laboratory, another sign of LG's commitment to excellence. CO: The Mono X"'module is the first in the world El aulhurized to display the CarbcnGee Cei Gfiec' 25w LG AWays stands by its products with sterling a aco,, Label,To be certified,the Mono X'"passed warranty policies.The Mono X'"support policy a rigorous Life Cycle Assessment from raw ® IS includes a 10-year product%vananly,a 12-year mat=rials to end of use. 90%power vernnty,and a 25-year 80%power ::•arrant% O O 0 Mechanical Properties 0 Electrical Properties(STC') - h Cells 6 x 10 LG24551C-G2 Call vendor LG Maximum power at STC(Pmax) 245 Cell type Mmineysfalline MPPvolhge(Vmpp) _ 29.8 Cell dimensions 155 x 156 mmz/6 x 6 in' MPP current(Impp) 3.23 . . . - --. #of bulbar 3 Open circuit voltage(Voc) 3:.0 Dimensions(L x W x H) 1632 x?86 x 42 rnm Shod cirmit mrant(Ise) 8.67 6425 x 3S.82 x 1.65 in _ Module efficiency(%) 15.2 Maximum load(Pa)' 5460(113 pef) Operating tomponturo('C) -40--90 Weight 19 kg/ 1189 lb Maximum system voltage(V) 600 Connector type' Tyce connector lP 67 _ _ Muimum series fuse rating(A) 20 Junction boz IP 65 pith 3 byres,diodes Power tolerance(%). O-t3 Length of cables 2x1000 rnn/2 x 39.37 in .p�„r,v:�cts:� :rs ro ¢m.er„1er,m:,.,a0w e'/RA�,�e„lo:•,,,,n.,.:�,�se.au is •.tl,11.IEC I:aMu& 'R+-11.4,pam--.I:ni:arueeaW:k.4,mbwiM LG El,,,—I in—and WmlWr 0 Certifications and Warranty 0 Electrical Properties(NOCT') Certifications IEC 61215 Ed.2,IEC 61'30,VL 1T03 Product warranty 10 Years LG245g1C-G2 Output warranty of Amax 12 years-90% Maximum p.or(W) 172 25 years-80% MaA.,m powervoltage(V) 2725 Maximum power current(A) _ _ 6.31 0 Temperature Coefficients Open circuiholtage(Voc) - _ 3445 Short circuit current(IrQ 6.70 NOCT A3.732'C Efficiency reduction Pmpp -0,469%/K Vre:n loon W/m'1.Zoo wlmy c 4.5% Voc _ -0.125 V/K,-0.33E%/K ve..<r rn lrzet:r.om,,,roa<r:a�no c.nx�o<r.w:ellr„d�.na eoe Allmr.,me�:ru<me<r.w..zo'0. - Isc i78 rnA/K,0-043%/K •.na.c..e l...h 0 Characteristic Curves 0 Dimensions(mm/in) o 'i �I i 31 x < a. v .wow 5 a u T eoow ' 4 {00 W ••w•Nr\� 1 200 W O 5 10 15 20 25 .10 35 40 Velt.,y.M _ Ido EI¢o _... .. ._ ....._...__....____ ..._._... . n `\ - Isc F 100 e0 .. VO< ...... 6 y e eu Pmax � -T6 -4a -25 0 2e 50 75 so Tmmpemfure CCl �C n.e meaoo l.a.....n T,.rt I1h.mn..n,;r ula•^•d;-y l.e..+ n /yZ� I1LI'7-.■i/V7�111 LG CI I -c l5> I ICJ 0., n d rin;, NJ 0., Life's Good v y 9 , .eT. on L n :.r.e gn re a e ❑� [ o ei-one® AURORA [hongingrheShopeofeower Photovoltaic Inverter a General Specifications Outdoor Models PVI-5000-OUTD-US Pill-6000-OUTD-US -- High-Efficiency, 5kW to 6kW Inverters Installer Friendly Aurora*grid-tie transformerless inverters offer a unique combination of •Reverse-polarity protection minimizes potential damage caused by ultra-high efficiencies, installer-friendly designs, long service life,and miswirinp during installation. competitive initial acquisition costs; significantly increasing return on. •Front-panel mounted LCD display provides real-time updates for all investment in solar-power installations. critical operating parameters. •RSd85 and USB communications interfaces. Industry"Leading features and Performance •Integrated DC switch available in compliance with NEC Standard, •High e0lclencles deliver more energy—up to 97%(96,5 CEC). Article 690"Solar Photovoltaic System"(USA) •Two inputs with independent MPPTs, optimize power from multiple •Anti-islanding protection arrays oriented in different directions. •Compact size and high power density.600OW max of output power in r a. ,, iA ,„ -"` •, �.; .; 'r a box just 38 518"x t213116 x 711/16' d PVI-5000-DUiD 5kW Unmatched Applications flexibility PVI-6000.OUTO BkW •Full-rated power available up to 50'C ambient temperature. •Dual Input sections with parallel option,with Independent high-speed Auror7Easy municator software simplifies monitoring via PC. MPPTs,optimize energy harvesting from multiple arrays oriented in AuroraControl datalogger Is available for remote control different directions. via Internet,modem or GSM •Wide MPPT operating range:90 to 580VOC Field-Proven Reliability •IP65(NEMA 4)rated enclosure withstands the harshest environmental conditions. • Front-mounted heat sink resists contamination,enhancing coofing and increasing reliability and long-term efficiency. • Grid-connected operation according to international standards, UL1741AEEE1547 8 CSA-C22.2 N.107.1-01 • Ten-year warranty,optionally extendable to fifteen and twenty years. MVMIT007 AURORA wer Photovoltaic Inverter High Efficiencies Across a Broad g00% Range of Operating Conditions 97 PVI-5000andPVI-6000 inverters provide 2061240271 96.8, Vac selectable outputs,at up to 97%efficiency(GEC c 96.5 96.5).The graph to the right demonstrates the high 75% 96,2 efficiencies, across a continuous range of input f 9 voltages and load conditions,for the PVI-6000. ; 95. The graphs below depict the industry-leading performance of all models at three discrete 50% v '95.3 MPPT-voltage reference points, and a continuous o [' .195 range of load conditions. t "a 94.7 30% 94.4 94.1 a ,.. 93.8 .20% 93.5 r 93.2 95� ' 92.8. 250 300 345 400 480 - DC Voltage(V) t f00 .......,.......1........-------. ------1------- ,-----..-............... .. es ---..a...... , no x +emva 70 i 0 01 0,2 0,3 0,< 0,5 0,8 0,7 0,8 0,9 1 %of ROW Output P*Mr AURORA MCMIT-6077,9f Photovoltaic Inverter - INPUT PARAMEIERS(OC Side � Nominal DC Power 5.15 6.18 Total Max.Recommended DC Power 5.3 6.4 ODerednp MPPT Input VOAage Range CI 90 to 560 360nomina Full Power MPPT Range M 140.530 1 170-SM Mex.l Yalta _ 600 Acbvadon Voltage M I 200 nominal(ad]uslaNe within 120-350) No Of Independent MPPT Trackers 2 y Max.Input Pourer Each MPPT M 4 4 No.Of DC I 2(1 each MPPT( 2(1 each MPPT( Max.DC Gument Each MPPT A 18(22 short drwit) 18122 short arcuh Thermally Protected DC Side Varfstor 412 for each MPPT) DC Switch Integrated(Ratirrg:600Vdd25A) 4(2 POSITIVE,2 NEGATIVE) DC Connections SCREW TERMINAL BLOCK 3 KNOCK-OUTS:G161/Tor G1'(using ring reduction) CONDUCTOR CROSS SECTION:MAX AWG4 OUTPUT PARAMETERS AC Side Nom el AC Power Max.AC Power 5000 6000 Grid Connection singe phase/split phase i Nominal AC Voftaae Ranne M Delauh:240V SOIA phase Optiarrel:208 or 277 sirmle phase fsetfi re uimd) Mumum AC Volta Ranged 187.2.224.6;216.259.2;249.3-299.2 Nominal AC Fn*incy IHzj60 Max.AC Line Current A 24 20;18(30 short drain 29;2521.6(30 short ccaitl AC Side Varfstor 2(Uve-Neutral!Live-PE SCREW TERMINAL BLOCK AC Connection 3 KNOCK-OUTS:G18t/T or G 1'(using ring reduction) CONDUCTOR CROSS SECTION: AWG418 Une Power Factor 1 AC Current Distortion HD !2%at rated power with sine wave voltage Max.Efficien 97% EC EfWerkcv 96.5% Feed In Power Threshold 20 Night Tim Cons lion <2 Isolation - Translormeraess ERVIRORMEIttAI PARR AFM Coolino Natural cooimg AmbientTTe f°CI -25l.60(ouLW p9mrar derabng above 50•J El coustical Noise dBA c 50®1 mt Environmental UP Rating — - IP65 Relative Humldiy 0.100%andensin MECHANICAL _ 6'3f Dimensions HxWxDl __ Inches 385/WxJ2116'x7111i Weighty rosl —_ -- 66 OTHER DI lap_-_ --� YES(Alphanumeric 2 lines) RS485(Spring terminal Nock-Conductor cross section:0,08-1,5mmyAWG28-16) mmunicatlon USB connection(Service) ` 'aurora Easy-Control'system for remote control(Optional) Slandards and Codes Aurora inverters comply with standards set for grid-Ned operation,safety,and electromagnetic compatibility including,U1.174111EEE1547 6 CSA-C22.2 N.107.1.01, VDE0126,CEI 11-20,DK5940,CEI64.8,NEC 67683,IEC 61727.EN50081,EN5DO82,EN61000,GE CerMiation,El Real Decreto RD166 ODO de Espana JO, Ass AURORA 0 AfY �-e O/l 9 P Photovoltaic Inverter Changing the Shop?of Power Block Diagram and Operating Configurations eo�1 GFC1 Fllff "ftGM hurter 4 � PJAmy 4 VeFfiWVma :.':::. BaAeO&mttl 06etr05Po2oe Vnoar 000V Mi erumeswr eyamn eeetrmer P f Inverter electrical block diagram i ---------------------------------------------- Be s¢neb • 1 P ftPW12 i MPPT 1 i -MPu112 — i AC Oulpul ' MPPT2 OCIAC tIIV@rier I i t Pvla8110-0uTn•8I Pvla000-0uTo-3 r ew.1.1 knoAD,2409 1 Power-One Inc. 740 Calle Plano Camarillo,California-930124593 I 8esales-us40power-one.cDm www.power•one .com � N y GREENFASTEN" PRODUCT GUIDE - GF-I GFI-L r 1 � ff `� � � Q�MHbMO V/6WNM1 t © MnilMp i ^ F(F � 1 K 0 0 N 1 y 0 E ' r v r n r � T ® - a SECTION A-A f N><D Qn �c � o w S ©EtoFns;en 5dc,0 Nl concen:poreaed vMer coDYr;ck Nl.igbts reserved.03/81f1 g�,q-I a, A GREENFASTEN'" PRODUCT GUIDE - GF-I " , t k GFI-L812 r 1 1 l� 7 —8.000 .005 — R.38 032 0.88±.01 ;l v w _ 12.00,- .125 / 0•30+.01 0 �+ a r \ C 11 4A k p N tf�-- ' !'• s 3.00� .125 V 4.00+ .125 .26}.01 — r — .05 may P M D` M ' W e w m � Finish Options BLK= Matte Black BRZ= Medium Bronze ?� LL MLL= Mill Finish i � o 1 0 Ec.Favii S*,G IV comem proteaed wide.copl*IEIn A7 gIiu reserved.0318111 Sec.4-2 111 1 e a GREENFASTEN'" PRODUCT GUIDE — GF—I i $ I Bracket Options - CP Round .x 0 .377+.002 06 7H R U ALL 31 0 .875±.010 X 820 u � v v 01.75 a.lr a 4� O 1 � O 1 C 1 � N p E r � i l h fi c w r\ c � U W t � I 11 ®lcfmtrn W,,,u AOcomem wmwedwderco v€cANrH,b and 03/8/I1 Sec.4-3 J GREENFASTENTO PRODUCT GUIDE — GF-I Bracket Options- CP-SQ It ------y ' • . � : I .3752:.008 / y is • m I � 2.000=.025 �{ i � ! • 1 K � o Ax N 2.000 A.025 W o n � L !/ V i n r c n 0.377t.010 THRU CD .875±.010 X 82' NEAR SIDE 0 Y N Compression Place 2" X 2" Mill Aluminum w ! r 0 EcAslen S*Q M mncen:prormed S�4-4 / i +t GREENFASTEW PRODUCT GUIDE — GF-I Bracket Options - F-I I I • r. 2.25 I' 2.04 2XR .06 �r 1.00� I !: 1.00 .88 J, r {��VJ, IJI 38 Unless Otherwise Noted all R .02 1.13 I 2.25 � 006 � v I 0 .377+.002 THRU ALL I � 'il CI II `:•� ;,; :i: 0 .875±.010 X 82°, NEAR SIDE a 1.00 Cr IXI II IW E r o IIA I M 2.00 M ° i ie 2 'E E nl i iii iu N ` m r n U O 1 � w I ®Eca1»srcn SMe,Q Mmmen:pmlecicd urber cop�liglle Nl,iy111s resents.03/9lll SE .4.5 r 1 ! ,• , u GREENFASTEN`" PRODUCT GUIDE — GF-I d Bracket Options - L-101-3' t "Y A R•06 ,.<• 25 •41 r� L , i. 3.00 2.25 R.13 1.65 v 3 N 31 -------------------------v R19 w� C Ib ,006 ' c L 0 .377+•002 THRU ALL 0 •875±•010 X82°, NEAR SIDE I I j ' r I r � o i� 75 y � ro w 1 i 7 FiE<olozren$0/vN1 AU mmenrprorened under ropyriEla Mriyilu mserKd. 0718i11 $ee.46 t I � GREENFASTENr" PRODUCT GUIDE - GF-I Bracket Options- L-102-3" 2X .38 i K ^�6— e — 2X .94 r t, Q Jry 1.13 1.88 s Lf 0.38 THRU 0.88 X 82° NEAR SIDE E i E _ � V I M a ri n `n O to i , Y `1 e LL 0 w t I II 9&oknien SoInrG9 AN mnien;DrotMed wrier copyrie m AA r Him reservM.0318/1 1 $ix.47 q , i jp { GREENFASTEN'" PRODUCT GUIDE - GF-I Bracket Options L 102 6" .41 h ( I 6.00 + 5.25 t t Q 1 13.65 e 38 + 3.09 p 1.49 r � t77"� }� o —� 3.00 � 2.00 -� I N p 1.50►{ +.006 0 .377_.002THRU ALL ' i r 1.00 / U 0 .875(+010) X 82°, NEAR SIDE / v c W r � o I c i11 � O �r W F � 1 p. 0 EaFa,wo 501ma AU mnmm Vm wa d,.,e,coDYrik t A fi&�d 0318111 SE A-8 GREENFASTEN'° PRODUCT GUIDE — GF-1 t r� Bracket Options-Z-101 .63 F .38 I I I I I I I — .41 y.. 1.25 .19 � �� .19 1 I 1 1 I� c 4X R.10 f 3 2.75 1 ( 31 l E 1.50 +.006 rr .377-.002THRU ALL 0 .875±.010 X 82°. NEAR SIDE 0!0 � 1.SO0 0 I 75LT w 7s ! I ®EwFasrerr 5obr®Ag vMej,VwJWa urldcrr copYrigl¢AN riglo rt Yr 4..C31811I Sec.49 I t I FLANGE NUT END CLAMP 0 OP MOUNTING FLANGE NUT CLAMP MID CLAMP T-BOLT 0 UGC-1 CLIP T-BOLT SOLAR MOUNT RAIL -T-BOLT UGC-1 i CLIP RAIL O 00 U x IN Ac @ 000 00 Installation Detail ©2008 UNIRAC. INC. SolarMount Rail ALBUQUERQUE,, NM 87 Oz EUSA Top Mounting Clamp PHONE 505.242.6411 UNIRAC.COM Universal Grounding Clips URASSY-0006 5:` =utc�oU Cecail Itrary`C>D`-..2=.SSY—JC'E—Salor IAcjnl Roil—UGZ-1 ,^.lip—TC[ fbur: ,larp.dvc. _'/22;21OE 3r17:`3 N,f k cU t 0.75— 000 N U INO 00 SolarMount ©2008 UNIRAC. INC. Standard Rail 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA PHONE 505.242.6411 UNIRAC.COM UNIRAC-300001 ,HN — Smart Synch° V the smart grid intelligence company" I CENTRON® GPRS SmartMeter SmartSynch's AMllntelli9 9 enceT metering solution features a communications module that is integrated into the Bran CENTRON electricity meter.The CENTRON SmartMeter communicates h - with a server running SmartSynch's Transaction Management System^^(TMS)and complies_ J with ANSI C 12.19 protocols for data storage n transmission. P 9 e and onset scion. r This solution delivers actionable intelligence(critical usage and rate data)over secure public } � wireless networks(such as AT&T and Rogers Wireless)and the Internet-in lieu of cumbersome and expensive private networks.This makes mass deployments quicker,easier,and more - scalable,providing a significantly greater Return on Resources(Rol?) for utilities. p Unlike proprietary,closed-architecture solutions,the CENTRON SmartMeter is essentially a future-proof investment in technology.its standards-based IP connectivitymakes it ad table /fran aP i and field-upgrodable to support today's censoring and communications needs,as well as tomorrow's opportunities,better than any alternative. Functions & Features Wireless Networks Hardware Components { •GPRS • Radio Control Module Board(RCM) Advanced Metering Functionality • Capacitor Storage Bank(CSB) • • GS Flexible Internal Modem le Two-Way Data Retrieval Antenna •Scheduled and On-Demand Reads • Tit Detector • Interval Reads(5, 15.30,60 minutes) • Temperature Sensor • Reol-Time Interval Reads •Automated Register,Self-Reod&IOU Retrieval Operating Ranges r, • Demand Resets Temperature • Real-Time Meter Event and Alarm Retrieval • Real-Time Power Outage and Power Restoration • Operating: (GPRS): :1-400 •Service Diagnostics and Tamper Detection • Transmission(GPRSJ:(-40°C,+g5°CJ •Tilt Detection Humidify r d • Meter Clock Synchronization •0%to 95%non-condensing • SmartMeter Status Display Accuracy • Automated Meter Registration • Meets ANSI 12.20 for accuracy class 0.5% • Secure and Encrypted Data Transmissions • Bi-Directional Metering Regulatory& Industry Specifications • Over-The-Air SmartMeter Module firmware • FCC Part 15 Class B t Upgrade • ANSI C37.90.1-1989:(SWC) Supported Meter Forms • ANSI C 12.20(Class 0.5)-1998 • Class 20:3S,4S • PTCRB Certified • Class 100: IS • Network Carrier Certified • Class 200:2S, 12S.25S • Measurement Canada Certified OSmarlSynch.Inc.4400 Old Canton Road • Class 320:2S Jackson.Mississippi 39211 ( 1-88&362-1780 .,s vi.snio0synch.corn Hardware Specifications Smart Synch- Hardware Component Description Radio Control Module Board(RCM) 32-bit ARM processor,256K RAM,512K flash Capacitor Storage Bank(CSB) Supplies peak power for data transmissions and all functions during power outages-no batteries required �) GSM/GPRS Modem GSM modem communicates with head-end using GPRS and SMS services Internal Antenna Flexible dual frequency GSM antenna for the modem ' Tilt Detector Detects unauthortsed movement or removal of the device )) Temperature Sensor Monitors all temperatures to ensure correct radio operation 1 { Temperature Ranges Supported Meter Forms Operating:]-40°C,+85°C] Class 20:3S, 4S Transmission(wireless):[-40°C, +85°C] Class 100: IS Class 200:2S, 12S,25S Humidity Range Class 320:2S 0%to 95%non-condensing Regulatory&Industry Certifications FCC Part 15 Class B Accuracy ANSI C37.90.1 -1989:Surge withstand Capability (SwC) ` Meets ANSI 12.20 for accuracy class 0.5% ANSI C)2.20 (Class 0.5)-1998 PTCRB Certified f Measurement Canada Certified Network Carrier Certified Input/Output Signal or Interface Definition/Values fffc Module Power Input Voltage 120 VAC Meter Serial Interface 3.3V/TTL compatible asynchronous t Integration The SmartMeler module is a fully integrated,under-the-cover option inside the CENTRON meter.The CENTRON GPRS SmarlMeter is shipped as one complete unit,ready for field deployment. Version and Compatibility Information CENTRON Meter Hardware: Supported meter forms,classes,and types,equipped with battery CENTRON Meter Firmware: TBD SmariModule: CENTRON GPRS SmarlMeter Module r r SmartSynch TMS: Version 7.20 or higher About SmartSynch: Headquartered in Jackson.Miss..SmartSynch has been developing successful Smart Grid Intelligence solutions for the utility industry since 2DD0.The company's clears-tech innovations in the two-woy delivery of real-time energy usage doto over public wireless networks(AT&T,Rogers,etc.).in lieu of private network build-outs,have to date simplified SmarlMeter deployments far 100 major North American utd8ies,while enabling green-energy initiatives and delivering significantly higher Returns on Resources. Unlike proprietary,closedbrchifecture solutions,SmarlSynch's SmariMelers represent future-proof investments in technology.The standards-based IP connectivity enabled in every SmortMeter deployed makes them adaptable and remotely upgrodable to support today's sensor and communlcotions needs,as well as tomorrow's opportunities.better than any all Motive. Cop ht®20W.SmortS nch Inc..all ri hts rezeried. - SOLARMOUNT Top Mounting UniRac Grounding Clips and WEEBLugs - 225.6 UGC- 7 Top °t mounting clamps A Module I q ;} iboll Nib Figure 26.Slide UG lrounding _ ems UGC-I dip into top mounting slot ofmil. Intertek Torque modules in place on top of eo„re„m re _ _ Aitionn doneatenaterangpat- ucsr.�u.,dm _ iaadona will petegroandinneod. through mU(aee Fiy 3,ressrte side). SolorMounl$rail[any lypai F(gure 27-Inserta boltin the WEEBLUg - ahantnum railor through the dearance hole is thestainlesssieel. - fkr .euher.Place rhesiainim steel ` - -- flatwasher on the bok oriented _ so the dimples will contact the ! - aluminum raliL Piece the htgportion a. on the bolt and stainless steel flat ! washer.histal(staml6s steeeiflat " washer,lockwasherandnut WEEBW9 t Tighten the nutunnl he dimpleg a- t 1 Ten I-ely embedded mtii therdU l - a ndlug.Theembedded dunppl.make - SlWcislis Steel p) cmdencgas�ighf regoodelectrcal oonnct W6stiar(WEER) - mtdmsuregoode]]ecru�ical mrmecNon beiwern thealuminumrad and the J+'"�ro yp�yn elipsend lwv-ewW eep ol'. INg tlaaugh the WPEB. '��'� l t�l6ral .. ` . ..•>M� (any type) Figure 28.UGC-I layout for even and odd number of modules in row. ox-denotes prates to install UGC-7. Even Number ofAlodules in row Odd Number of Modulo in row •°'U N I RAC@ Pub ne2011 June 011 �� m2DII Dr Unirag lnc A min GROUP COMPANY Ail rights reserved. Wiley Electronics LLC Washer, Electrical Equipment Bonding and Lug (WEEBLug) The WEEBLug is a device for bonding a solar array. The WEEBLug consists of two parts: a stainless steel washer(weeb-6.7)and a tin-plated copper lug. The washer is designed to provide a reliable gas-tight electrical connection with anodized aluminum pieces. The lug allows the lay-in connection of an electrical equipment grounding conductor. The WEEBLug may be attached to the top of a mounting rail with a captive bolt, or fastened to any aluminum piece after drilling a suitable size clearance hole(see part number list below). Figure 1.WEEBLug Usage: Insert a bolt in the aluminum rail or through the clearance hole in the aluminum piece. Place the washer portion on the bolt, oriented so that the dimples will contact the aluminum piece. Place the lug portion on the bolt and washer portion. Install stainless steel washer and nut. Tighten the nut until the dimples are completely embedded and the lug and aluminum piece are flat against the body of the WEER. The embedded dimples will make a gas-tight mechanical connection and thus ensure good electrical connection between the aluminum and the lug. copyright 2006 Wiley Electronics LLC Figure 2.WEEBLug mounted on rail. • Material: 304 stainless steel,tin-plated copper • Listed to UL467 by ETL • Torque to 10 ft-lb using general purpose anti-seize • Maximum electrical equipment ground conductor size: 6 AWG • Use with '/," hardware (included) • Outdoor rated Part number: WEEBL-6.7 for use with 1/4 inch mounting hardware WEEBL-8.0 for use with 5116 inch mounting hardware WEEBL-8.2 for use with 8 mm mounting hardware copyright 2006 Wiley Electronics LLC