Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
1 MOFFATT RD - BUILDING INSPECTION
< K 6 0 y /l o oLU INSPECTIONAL SERVICES p The Commonwealth of Massachusetts ;T �e Board of Building Regulations and Standards ;1014 UG sffy ID b Massachusetts State Building Code,780 CMR Revised Mar 2011 Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use-Only Building Permit Number: Date App ' d: Building Official(flint Name) Signature Date SECTION t:SITE INFORMATION 1.1 Property Addre s• 1.2 Assessors Map&Parcel Numbers t lL (, H-- rd . ).1 a Is this an accepted street?yes .X no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record• <7�1Y1 -rh &, SaleM MA Name(Print) City,State,ZIP No and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK (check all that apply) New Construction If Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ Other ❑ Specify: Brief Description of Proposed Work: p V }GLIG Sol0.r SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials 1.Building $ .OD 1. Building Permit Fee:$ Indicate how fee is determined: 13Standard City/Town Application Fee 2.Electrical $ ❑Total Project Costs(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ �� T 4. Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ G Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ J '7 ]) ❑Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 045 2_5 4 2,$ m ILYAe5 V\Q}rr/lLQYI License Number Expiration Date Name of CSL Holder 8 I 1 ' t n S:ixeL List CSL Type(see below) U No.and Street 1 Type Description SCl Ll� �S Q q U Unrestricted(Buildings u to 35,000 cu.ft. R Restricted 1&2 Family Dwelling Lityll'own,SZIP M Maso (/ RC Roofing Covering WS Window and Siding 1-F '�G.� SF Solid Fuel Burning Appliances SIJ Vwa �6Q vivo '&r. I Insulation Telephone Email address Corn D Demolition 5.2 Registered Home Improvermeen,,t Contractor(HIC) CC )�l✓�� So -x 1Jeye�O��ey LLC HIC Registration Number E para on Date HIC Company Name or HIC Registrant Name f�31 N DO W . nnGtSr�larc�JvtvtvLFso r. No.and Street Email address �ryt PrOYo l?>— ��(00� —[$1305301Q5 Ci /Town,State,ZIP Tele hone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ........... No...........17 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize VIV 1VItt So ICl-r to act on my behalf, in all matters relative to work authorized by this building permit application. _ - . - -- - - --__—.....-_.--------_ ----- Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER`OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in th' p ' tion is true and accurate to the best of my knowledge and understanding. Print Ow s r rized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dos 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost' -7 / 7 e DATE(MMIDONYYY) A`oRo CERTIFICATE OF LIABILITY INSURANCE 11/01/2013 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EYTEND OR ALTER THE COVERAGE AFFORn n BY TH POI -IFS BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements). PRODUCER CONTACT MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 PHONE FAX JAM, DENVER,CO 80202-5534cepop IILL$s. No: Attn:Denver. rtrequest@marsh.com,Fax:212.948.4381 INSURER(S) AFFORDING COVERAGE NAIC0 462738-STNDGAWUE-13-14 INSURER A:Evanston Insurance Company 35378 INSURED INSURER e:National Union Fire Insurance CO of PA Mvmt Solar,Inc. 4931 N 300 W INSURER C:New Hampshire Insurance Company 23841 Prow,UT 84604 INSURERO: INSURER E: - NSURERF: COVERAGES CERTIFICATE NUMBER: SEA-002368030-06 REVISION NUMBER:O THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRADOL UBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE POLICY NUMBER MMA)DIYYYY MMIOD/YYYY LIMITS A GENERAL UAMUTY 13PKGWE00274 11/01/2013 11/01/2014 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LI ABILITY DAMA ( REN 50,000 PREMISESSEa accumerxa $ CIAIMS-MADE MOCCUR - MED EXP(Any we person) $ 5,000 PERSONAL B ADV INJURY $ 1,000,000 GENERAL AGGREGATE S 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 X I POLICY PECT R0. LOC $ B AUTOMOBILE LIABILITY 9701067 11101/2013 11/01/2014 CEOM�BBIINED SINGLE LIMIT S 1,000,000 B X ANY AUTO 9701086 11/01/2013 11/01/2014 BODILY INJURY(Per person) S ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS I X HIREDAUTOS X NON-OWNED PROPERTY DAMAGE $ AUTOS Per awdeM $ AUMBRELLA LIAR X OCCUR 13EFXWE00088 11/01/2013 11101/2014 EACH OCCURRENCE $ 10,000,000 X EXCESS UAB CLAIMS_MAD ___ AGGREGATE g 10,000,000 DED RETENTION$ g C WORKERS COMPENSATION 029342334; 029342335 11/01/2013 11/01/2014 w /MIT- oTH- AND EMPLOYERS'LIABIOTYERS ER C ANY PROPRIETORIPARTNER/EXECUTIVE YIN 029342336; 029342337 1110112013 11101/2014 1,000,000 OFFICER/MEMBER EXCLUDED? IN] NIA E.L.EACH ACCIDENT $ C (Mandatory In NH) 029342338 11101/2013 11/0111014 E.L.DISEASE-EA EMPLOYE E 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT E A Enors&Omissions& 13PKGW00029 11/01/2013 11/01/2014 LIMIT 1,0)0,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ANach ACORD 101,Additional Remarks Schedute,N more spam Is nx lrW) The Certificate Holder and others as defined in the written agreement are included as additional insured where required by written contract with respect to General Liability.This insurance is primary and non. ontributory over any existing insurance and limited to liability arising out of the operations of the named insured and where required by written contract.Waiver of subrogation is applicable where required by written mumt with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORD:ED REPRESENTATIVE of Marsh USA Inc. Kathleen M.ParsIce .J�ts.(luix.h[. 4w 4e, ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD I 4931 North 300 West,Provo.UT$4604 • • rx Employer Identification No.: o.: 170438 vivint SOI A Phones(877)404-0129 Fax:(801)765-5758 Mas achusetts HIC Li erase No.: 170848 • d E-Mail: support@vinntsolacwm ppa I www.vivintsola.cam AR No.' 38 1(p4-IS RESIDENTIAL POWER PURCHASE AGREEMENT This RESIDENTIAL POWER PURCHASE AGREEMENT(this"Agreement')is entered into by and between VIVINT SOLAR DEVELOPER,LLC,a Delaware limited liability company("We',"Ile,"Our")and the undersigned Custuarms)("Yoe", 'FC-l"),az ofthe Transaction Data set forth below. Full Name ii r ut two Pull Name rF.,c mi.tarn Customer(s): m ,4ii ,:o r.,o n P-W, os—,:o r,.,n,va Telephone No.: Q}� E-Mail: Property Street Address: Address: City,County,State,Zip: 1.SERVICES ' 'A DESICN AND INSTALLATION. We will design,inslalh service and maintain a sola photovolmic system on Your Property,which will include all solar panels,inverters,meters,and other components(collrtively,the"Systnn''),as further described in the Customer Packet and the Work Order that We will provide to You hereafter. All material portions of the System will be installled by Our employed technicians and electricians,and not subcontractors. With Your cormerasion, We will (i)design, install and connect[he System in malenal compliance wit h all applicable laws;/1i)Complete azl required inspections;and(iii)obtain all required cemficaions and Permits. h order m design a Syystem that meets Your needs,You a i electrical usage history from Your electne utility(the �")and You shall provide Us with copies of Your Utility bills as Wee mat aWe mMY obtain Your Othr than the activation fee described in Section LD,We wI I ddesign and install[he System at no cost u. B. ACTIVATION. You agree to pay Us a one-time activation ee m the amount of We will interconnect the System with the Utility,and cause the System [o generale energyy measured in kilowatt hours (kWh") (the "race nstallation of the System generally rakes one day and is an'iupated m begin and be sabsunit ly complete between two('_)and six(6 weeks hereafter. C. OWNERSHIP OF SYSTEM. We shall own the System n Our sole personal property. You will have no property interest in the System D. OPERATIONS AND MAINTENANCE. We will operate aad'maintain the System(i)at Our sole cost and expense;(ii)in good Condition;and(iii)in inatenal compliance with all applicable law,and permits and the Utility's requirements. E. INSURANCE. We carry commercial general liability insurance,workers'compensation insurance,andpropertyinsurance on the System. For more intormationconceming Ounnsumnce,andtoobwin a copy of Our certificate ofinsurance.please visit: www.vinolrcominsurance. 2,TERM,PRIG PAYMENTS•AND FINANCIAL DISCLOSURES The F Energy Price sshhall-increaseleach yearby two andtnmc tenths pstcan Vercena UsAOgoo 1 t esoMmyte of the Staystemnoutp Price"), measured plus in kilowatt hours, will be provided to You Iv the Customer Packet. THIS AGREEMENT IS H SALE OF ENERGY BY US TO YOU AND NOT FOR'I'I IG SALE OF A SOLAR ENERGY DEVICE. B. TERM This Agreement shall be effective as of the Transaction Date and continue until the twentieth(20")anniversary of the In-Service Date(the "Term"). The`In-Service Date"shall be the first day after all of the following have been achieved: (i)the System has been installed and is capable of generating Energy,(ii)all permits necessary to operate the System have been obtained,(iii)the System has been msereonnecte Inspections and cemficates required under applicable law or by the Utility have been completed or received. with the Utility,and(iv)all C. PAYMENTS. Begginning with the first month following the In-Service Date and throughout the Term, We will send You an invoice reflecting the charges for Energy produced y the System in the previous month. You shall make monthly payments to Us by aummauc ymenl deduction from Your designated checking account or credit card. It is Your resp snsibility to ensure that there we adequate 1'uvds or adequate credit limit. There Is no Flan our charge associated with this Agreement. For all payments more than ten(101 da s past due,We may impose a late charge equal to Twenty-Five Dollars(S25) and mscrest at an arcual rate of ten percent(10%),plus applicable taxes. f You continue to fail to make any payment within ten(10)days after We give You writer notice,then We may exercise all remedies available to Us pursuant to Section 13(b), D. RENEWAL. At the end of[he Term,You may elect[o(i)continue with dlia Agreement on a year-to-year basis;(ii)enter into a new Agrcement with Us and cancel this Agreement;(iii)purchase she System at the end of the Term antl wneel this Agreement(the"Purchosr Option') or(Iv)cancel Olis Agreement and have the Syasem removed at no cost m You. Vou will need[o notify Us in writing conceminp Vour election sixty(60)days poor to the end of the Tetra. ff You elect the Purchase Optioq the"Purchase Option Price"will be the[hen-current fair market value of the System bated on an indcpendrnt appraiser's valuation of similazly sized photovoltaic systems in Your geographic reggion. The appraiser's valuation will be providM to You in writing and will be hlnding. If We receive Vour payment of she Purchase Option Price,costs of the appraisal,applicable laces,and all ether amounts tMn _ owing and unpaid hereunder,We will transfer ownership of the System to You at the end of the Term un an"As Is,Where[s"basis. If You elect to have the S stem removed,We will remove the Syystem tram Ynur Fropp��nyy wiNm ninety(9t da}}'s aflu the end oft0e Tcrtn. IF YOU DONOT NOTIFY US OF YOUR ELECTION TO CANCEL RY SENDING A W72lTTEN NUTICE TD US, THh:N THIS AGREEMENT WILL AUTOMATICALLY RENEW ON AYEAR-TO-YEAR BASIS UNTIL YOU NOTIFY US IN WRITING OF YOUR ELECTION'FO CANCEL AT LEAST SIXTY(60) DAYS PRIOR TO THE END OF THE RENEWAL TERM. E. CREDIT CHECK. In connecron with me execmion of This Agreement and at any time during the Term,You hereby authorize Us to(i)obtain Your credit rating and report from credit rcpo0 aggencies;(ii)to report Your payment pCrformance under this Agreement to credit reporting agencies;and (iii)disclose this and other infnrmanon to Our atiliases end acetal or prospective lenders,financing parties,investors,insurers,and acquirers. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE (888) 567-8688. SEE PRESCREEN & OPT-OUT NOTICE(SECTION 29)BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. 3.LIMITED WARRANTY A. LIMITED INSTALLATION WARRANTY. Wz provide a workmanship warranty that the System shall be free from material defects in design and workmanship under normal n arresting conditions for the Tenn. We further warrant that a1 rmflop penetrations We install shall be warned t as of the date of installation. We do not provide any warranty to You with respect m any component of the Syysleet. Any manufacturer's warranty is in ad0nion to,not In lieu vl;this limited installation warranty. This warranty docs not tour problems resulting fiom exposure m harmful materials and chemicals, fire, flood, earthquake,or other acts of god,vandalism;alteration of system by anyone not authorized by Us,or any other cause beyond Our control. B. MANUFACTURERS•WARRANTIES. The Syssera's solar modules carry a minimum manufacturer's warranty of twenty(20 years az follows: (a)during[he firs[ten(10)pCam of use,the modules'clecMcal nmput will not degrade by more than ten percent(10%)from the ortginal[y razed outpput and b Bring theyfim twenty(20)years of use,the modules'electrical output will not degrade by more than twenty percem(20%)from the enginelly rated outyut. The S stem's inverters carry a minimum manufacturer's waffiri often(10)years against defects or component breakdowns. During the Term,We will enforce[hese warranties m'hc fullest extent possible. C. DISCLAIMER OF WARRANTY. EXCEPT AS SET FORTH IN THIS SECTION 3,WE MAKE NO OTHER WARRANTY TO FIOTNEOSS FORYANY PUR USEOOP THE LQUIPMENTSS, IMPLIED OR STA—fu I IINSTALLATION, DESIGN, OPEF RATION, OR MAINTENANCE AS TO THE L OF THE SYSTEM, THE PRODUCTION OR DELIVERY OF ENERGY, OR ANY OTHER ASSOCIATED SERVICE OR MATTER HEREUNDER, ALL OF WHICH WE HEREBY EXPRESSLY DISCLAIM. OUR LIABILITY FOR ANEXTENT REDY BREACH OF ANY EM OR YO R PROPERTY TO AGREEMENTISYOUTACKNOWLEDGE THAT WF.ARE RELYING ON THIS SECTION 3.C. AS A CONDITION AND MULRED ATERIAL ENT INDUCEMENT F ENTER HER THIS AGREEMEM. THERE ARE NO—A iFRNTIES WHICH EXTEND BEYOND THE DESCRIPTION T THE FACE HEREOF. 4.REMOVAL OF THE SYSTEM You shall not make any Alterations(as defined in Section 9 c to the System. If You want to make repairs or improvements to Your Property that require (the temporary removal of the System or that could mLLT ere wd its performance or operation,You must glue Us at(east thirty(30)days'Attar written nous a"Customer-Requested Shutdown"). You agree that any,repair or Improvement to Your Property shall not materially alter Your roof where the System is Intall ora nation for Our removal,storage,antl mnstallation of the Syystem,You agree to pay to Us a Fee equal to Four Hundred and Ninety-Nine Doll $499 afore We remove the System. You shall be required to pay the Shmdown Payment(as defined in Section I If the 5ystem is not reinstalled within[ i O)days of removal. In the event of an emergency affecting the System,You shall contact Us Imme rare y. If We are unable to timely respond,You may(at Your own expense)contract with a licensed and quahlied solar installer m remove the System as necessary to make repairs required by the emergency. You shall be responsible for any damage to the System that results from actions taken by Your contractor. 5.ARBITRATION OF DISPUTES Most customer concerns can be resolved quickly and amicably by calling Our customer service department a 877)404-4129 If Our customer service department is unable to resolve Your concern,You and We agree to resolve any Dispute(as define w g binding arbitration or small claims court instead of courts of gencml�Iurisdiction. BY SIGNING BELOW,YOU ACKNOWLED E AND AGREE THAT(p YOU ARE HEREBY WAIVING THE RIGHT TO A TRIAL BY JURY;AND(II)YOU MAY BRING CLAIMS AGAINST US ONLY IN YOUR INDIVIDUAL CAPACITY,AND NOT AS A PLAINTIFF OR CLASS MEMBER IN ANY PURPORTED CLASS OR REPRESENTATIVE PROCEEDING. You and We agree to arbitrate all disputes, claims and controversies arising out of or relating to c.rnam;::nr va„snylm..mr=,.iic nn u'em.a.",.<d. v.._m.eun'rn ins,a.m I uliFied b.im insrrtiman in wrilin 1 by hofh Ymruul Us OP OUR AFPILIA TES. DIREC'IURS, EMPLOYEES. AGENTS, 2I E,VtIAt A('REt t1t,M11 gma: aarmmcnt tic aJJt.ul Toms and OR CONTRACTORS FOR ANY "SPECIAL, EXF,M'PLAItY cold mi N Lsr I Pi k t mo W'mt Un r t vnv ud "poem W or {� INDIRECT. LNCIDENTAL, CONSEQUENTIAL OR PUNITIVE wnc .. m orrr II ah fin Ih I adr erne t I\o hid L's DAMAGES(W'Hf IHER OR NOT THE CLAIM TH'EREF'ORE IS arnl sopci h Il�p Or a ru get mm ............. is 1 I,dixwaemm wvd BASED ON CONTRACT,TORT,DUTY IMPOSED BY LAW(1R 'c p J ,' ppunan'nrk.Io m mi , u rhauf 2x Ul\OIVI EttFC Ae , n II h L Jr." I J i, r the OTHERW ISE).IN CONNECTION WITH.ARISING OUT Of OR �� t I of y an 1 U. n 1 OIr cod to pc h- P 1 p -nrn.ca, IN ANY WAY RELATED TO THE TRANSACTIONS s i sso and I I it I en.. F I d d in:66 CONTEMPLATED BY THIS AGREEMENT OR ANY ACT OR Ay .��t ill y1 ono It iia .y t I n d ng nor m mirn OMISSION OR EVENT OCCURRING IN CONNECTION n. v am a..' I mhy\ a m U] F ua r1 IIM ,Ad, THEREWITH. Y'OU[if REBY WAIVE,RELEASE,AND AGREE ascot LRvISI taW it lar I and 'n nv I � w�r�u NOT TO SUP. UPON ANY SUCH CLAIM FOR ANY SUCH t:imdl ic.l hbee n dn; and ,nu i the al I'll 0ou, DAMAGES. WIIF.TFIER OR NOT ACCRUED AND WHETHER rrwl II risco'" 'alxat. Ifml or 24 NOTICE UI t n, u len ml J in', In nc1, OR NOT KNOWN OR SUSPECTED -1'0 EXIST IN YOUR p rnittcJ 1u be i n ,� ler nus ;t «omni -h II h i, Ing dd' � m me FAVOR. YOU FURTHER AGREE THAT NO CLAIM. ppreahl v n til addtt f rib' th )Ere n t rt t. such m td casae I-AwsuIT. OR ANY OTHER LEGAL OR ARBITRATION >d 'CAl f t wool,h, a l , den p I> _ PROCEEDING IN CONNECTION WITII,ARISING OUF OF OR " cob, Itr, Au -u n I + ill I n,,1A5 m loll N h h o f 1 tt n1 d i m c h . -I , .ael shall B UG WAY' RELATED ED TCR THIS AM RE THAN MAY BE I t t the rl cat )ti�yz , II tt a 17 t9 ' dU BROUGHT, CO IF,i NC)E OR FILED MORE TL1AN ONL M. is.sn PRten rn. u R , n r o n i 6 1i YEAR AFTF-IL'TIIF.INUDEN'f GIVING RISE I O SUCH CLAIM. I ?hanhr l lr ,� : iro I-hi111 tiI I -e W d' gni 1 d" h nr 'f l be YOU ACKNOWLEDGE THAT WE ARE RLI PING ON THIS cdI d I I 1 ,J I'J pr h'h1 d I f silt, SECTION 17 AS A CONDITION AND MATERIAI I m II tK :Ire tl tl \ n i.l II r n 1,01 ti xc d n a r rda/ I DUCE:NE: TO ENTER INTO THIS AG R F:ENI ENT. 1 �. to, f r od,p b ht,nad 1 'c hl h 1 itis i Ih,o,f, in, vbp n hell h Fund, Tc. li1111 hltM. to c.hl w Ibe I8INDEMNIF'ICAII0N. 'Tu the fullest extent permitted by ox%noirri extoofI lin Ih "fi,it'L ta, applicable low, You hereby agree to indemnify advance expenv 27 Cot\FERP AREsto, \ba ,um naF F esl m ,arc and hold hamless Us and Our atfillntes. dilecton, an lo}ces u'n'tcrr rcrcrp ns sl Iib 1 11 .n tnr rn ';r me A t soul p ubl 1 I , Cnns1 l PJI I 111 111 I -cin nr "Conn, contractors and Our successors and assigns cast it 'Co,erecPerson") ersnn1 Iron any and all third partsclaims, actions. crmb n..a5l ne 1I.nt IAfP u1 ILmm e .CI t re,rn ph ,1I. I tI ,yrI s, >s . c cHs expenses(mcludmg Nasomble atlun,evsrcs and expenses) ,,it lis hatlt wl l damages, liabilities, um tics. losses obligations upm ius, emands .....'diem and hensofany kmdor nature In connection a Ith arising out of,or ,,"I o 11.1111 in any way mimed to(i)Your breach of this Agreement.or(i i)YomTHIS it ufn S. t x_8- neghgence or willful misconduct; prn,idcd that Your 29.PRF�LREF.N .AND SPT-OIIT �'UIICESED ON indemnification olhgamms under this Section 18 shall nut apply d' "PR. the harm or damage that is the basis for such third party claim INFORMA'I ION IN YOUR CREUI'C 1LEPC/RI INDICATING occurred while site of Our employees or agena was at Your Property THAI Y'OU MEET C'.ER'fA1N Cl2TI'ERIA. PHIS OFFER IS NOF RIA. IF and sucarm m h hor damage as solely caused by the active negligence GUARANTEED IF YOL; DO NOT MEET OUR CRITE urwilllulntiscnncluct,,Psuchemployeeoragent. YOU UO NOT WANT' TO RECEIVE PRESCKEENED OFFERS 19.SUBROCATION. You agree ro release all C'uvered Persons 01: CREDIT FROM US AND OTHER COMPANIES.CALL THE front any claims of an% parties suing through Your authority or in CONSUMER REPORTING AGF.NC'.IFS TOLL-FREE, (888) 567- Your name, such as Your.Insurance company, and You aggrree m 8688;OR W RITE: EXPERIAN OPT OUT,P.O.BOX 919 ALLEN, defend Us aeainst any such claim. YOU AGREE TO NOTIFY TX 79013; TRANSUNION NAME REMOVAL OPTION. P.O. YOUR INSLNANCE COMPANY OFTHIS RELEASE. BOX 505 WOODLYN, PA 19091; F(IJIFAX OPTIONS. P.O. 20.AMENDMENTS AND WAIVERS. lh1 AE cmeat.nay only be anoldcd nr BOX 740129 A"TLANTA,G:\ 30374-012.1. r r 1 ,YLi I vl. In.. IvVe.'rvil. (i)any aspect of the relationship between You and Us,whether based in contract, g tort,statute or any other legal theoryry (ii)this Agreement or any other agreement concerning the suhl'eet matter hereof; (iii) any breach, default, or termination of this Areement; and (iv)the interpretation,validity,or enforceability of"this Agreement,includin the determination of the scoQe or applicability of this Section 5(each,a Dispute"). Prior to commencing arbitration,a party must first send a written`Notice of Dis ute'via cerithed mail[o the otter .party. The Notice of Dispute must describe the naNre and basis for the Dispute and the reliefsought. ItPYou and M are unable to resolve the Dispute within thirty (30) days, then either p ma commence arbitration. The arbitration shall be administered by JAMS pursuant to rts Sveamline Arbitration Rules and Procedures(available ar: http://www.JamsadccoMmles-streamlined-arbitration,the"JAMS Ru/es'")and under the mics set forth in this Agreement. The arbitrator shall be bound by the terms of this Agreement. No matter[he circumstances,the arbitrator shall not award punitive, special,exemplary, indirect,or consequential damages to erthcr party. If You initiate arbilmtioq You shall be responsible to pa $25U. All attorneyys' fees,travel expenses,and other costs of the azbiValion shall be borne by You and Us in accordance with the JAMS Rules and appplicable law. The arbitration shall be conducted ata mutually agreeable looa[ion near Your Properrttyy. Judgmcut on an isitmlion award may be entered in anyy court of cum tent jurisdiction. Nothing in this Section 5 shall preclude You m We from seeking provisional remedies in aid ofarbivation horn a court ofecompe[entjudsdiction. NOTICE:BY INITIALING IN THE SPACE BELOW YOU ARE AGREEING TO HAVE ANY DISPUTE ARISING OUT OF THE MATTERS LNCLUDF,D IN THF, ARBITRATION OF DISPUTES^PROVISION DECIDED BY NEUTRAL ARBITRATION AS PROVIDED BY APPLICABLE LAW AND YOU ARE GIVING UP ANY RIGHTS YOU MIGHT POSSESS TO HAVE THE DISPUTE LITIGATED IN A COURT OR JURY TRIAL. BY INITIALING IN THE SPACE BELOW YOU ARE GIVING UP YOUR JUDICIAL RIGHTS TO DISCOVERY AND APPEAL. IF YOU REFUSE TO SUBMIT TO ARBITRATION AFTER AGREEING TO THIS PROVISION, YOU MAY BE COMPELLED TO ARBITRATE. YOUR AGREEMENT TO THIS ARBITRATION PROVISION IS VOLUNTARY. YOU HAVE READ AND UNDERSTAND THE FOREGOING AND AGREE TO SUBMIT DISPUTES ARISING OUT OF THE MATTERS INCLUDED IN THE`ARBITRATION OF DISPUTES PROVISION TO NEUTRAL ARBITRATION. I/WE AGREE TO ARBITRATION AND WAIVE THE RIGHT TO A JURY TRIALRb..al 91� 6.NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT: (i)this Agreement, n the A Terms and Conditions,(iii)the Customer Packet,and(iv)the Work Order. These documents are expressly ( ) to the relationship between You and Us. P y incorporated into this Agreement and apply B. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT. C. DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ ALL OF ITS PAGES. You acknowledge that You have read and received a legible copy of this Agreement,that We have signed the Agreement,and that You have read and received a legible copy of every document that We have signed during the negotiation. D. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES You are entitled to a completely filled in copy of this Agreement,signed by both You and Us,before any work may be started. (E(. YOU MAY 3 CANCF,L THIS'fRANSACTION A7 ANY T[ME((PR))IOR TO THE LATER OF: ([)MIDNIGHT OF THE THIRD TE)BUSINESS NOTICEOF CANOE LA ION BELOW OR AN EXPLANAHTION OF THIS R GHT.ALLATION THE SYSTEM. SEE VIVINT SOLAR DEVF- E C_ CUSTOMER(S): By BY t Printed Name: Printed Name: �- T IA. Title: Printed Nume: O Y a• 'T�k/..K. Transaction Daley (_21 , FOR INFORMATION ABOUT CONTRACTOR REGISTRATION J-21 CONTACT THE MASSACHUSETTS OFFICE OF CONSUMER AFFAIRS AND BUSINESS REGULATION:TEN PARK PLAZA,SUITE 5170,BOSTON,MA 02116, , (617)973-8700 OR 888-283-3757. y ____________________________.-_ NOTICE OF CANCELLATION Transaction Date: AR No YOU-MAVCANCEL THIS TRANSACTION N WITHIN THREE(3)BUSINESS S O ABOVE, TER) NTIL T A IN LLATION OF THE SYSTEM. IF YOU CANCEL,ANY PROPERTY TRADED IN,ANY PAYI MAD Y YO R N I KAUI OR SALE,AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED. IF YOU CANCEL,YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDENCE,IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED,ANY GOODS DELIVERED TO YOU UNDER THIS CONTRACT OR SALE, OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP OF THE WITHIN TWENTY(2200 DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION,YOU MAY RETAIN OR DISPOSE ELLER,OR IFS OIU AGREE. TO-RET OUT ANY THER URN HELGOODS TO THF. SELLER IGATION. IF YOU FAIL AND FAIL TO DTHE OSO THEN YOU REMAAVAILABLE TO IIN MA LLOR DELIVER A SIGNED AND DAAN E It TED COPY OF THISGA RCANCEL ATIONTNOTICE OR ANY OTH BNSACTHIN WR[T EN NOTICE,OR SEND A TELEGRAM,TO VIVINT SOL.�t DEVELOPER,LLC,AT 4931 N 300 W,PROVO,UT 84604 PRIOR TO HE LATER OF: (I)MIDNIGHT OF THE THIRD 3 )BUSINESS DAY ATT THE TRANSACTION DATE,OR(II)THE START OF INSTALLATION OF TE SYSTEM. 1 IEBY CANCEL THIS TRANSACTION: Date: Customer's Signature: fop.iisln 1::913 N.n,I�.Iur lArcMpv.l.Lt'.\II NiNliu llmrecl. ADDITIONAL AI 'FERNIS AND CONDITIONS 1. REPRLSENI'A1107ilS AND \WIRR\NIIFS Youwannot\ J Ther,ammonite this Agreement ntt Four D otticel to Y�ou andYou u will le mli'lted to ea nun 'h td III b ❑' n11 act )'ll fnnne b W P )➢ A 2a thf irlaym nl 'll be Lem t m I np I t I JY r the _ I to mp I ar(1 1 th r lsev I f t(5 v a (r year Pru, n A ha' Ill 1 I 'c he'll'l r let theP ➢n-11 lyuh M1I<61 n stalledi pl 'ip b bl las (the1 for Pay.1.1 AlaoAon vm Ila 'gum llgl rs It )Y - r1 to t1 p mU NeT frf 4 Ile f t hpl th S}It'mt V 'n coat vel pin vnAl Ile :m tl nF u } Irpa ndOYo idol WI hi h N [ lh.h J)g an Ncrp - Lot 11 Agnm I,d or baee h 1 i I O> rt t t 1 fi eir thr.Aep r t th(11 :aloe at_m t to p +powd tons el of Y ur p+h t Pr>Fm} fore-fe s a l r t J tnotion a� la,Y J u It Y nde u d Nm s m 4 Ac mot that t let simple I Y. II n n Imm 6Ie 1 ut n col' mix n r ss m a d n r a J by You s nit f brr ah I Y w hl at J r any Ag n v t Y it grcI that roc de th Full U t mus ons bre m r J r J I t the I I 'A A fi 1_'1(h) W h 11 11 F d neo t f f Y ur P•mprrty,Lind Wt II k 'th Your milk Aprt uol r u t is ext ll II tl n7i Oen c1 su :.r..and nen to lnnf it is Agn [Pt t11. th a and It me of 8. OUR 9ENVIn 15 fill alt A4 Il m ell p f amu et Q) ed l Scer 1216 �� ) OF DEFtULI ra Commune D lb It A-C roe De u11 :hell tans ih In i IraTe Ibv the sot We 'll ell tprkn tory CT Wt E1TS 1 J lo�m t h o O p+slnnel t Ale«theI t A4 all pm ale th - t Y thenen I a s o f a f1F v T l t t f In r mak am. P'vnem ape Your m ole V t Yo t etago,-O Ee..0 In maln a .t at this io n it N t 011i do,,o head 'nd ' rl Union, temed You Popov t 111 t: Ida Lh Atrd n WW n yn sttl r c ftl 'II' oil,(IDI tay. It Is II,,I V inch 11 al ,I'll Fail ;00 Your grant crl n n 'G ( et0( . If Rol d vt 'thttl nctc ` '« to in ,Itr blbuti J 'thsA a d ard,IwIme iset careal with im,,Nam Sio..Lot w,ft Ii, to niZIfibmill me holot.urn. :uoYoq Nmv Ourrday .11,W } - ncn t f: hlln ( )Yen d YYLx, ,and(it) k r i Wi tm ri 1 l _rnCh el 'rt i Indata (t 11ars mry n tnl � III m N UtlI cellnotour III,NCP ' f 1 h1 -ev Iffl n n rpe ll for uo Ind a proper, d. d t sat en withindarty 130)da IIT WIT gill YOU Your mal nruminantk kM1 d(adInternetOrel t )connections W tr tiul failureit) hovide I )Your hal pu 1 v heYml_-thdW PYrte (h)(a alts L ., s 11 tile SYtar u 1 v tI.lYLou, bttytp Y dltattonit ( IY(tPLO MnY Aon J r haL NII h Inarm W III lu n d:a ' m 1 t L t t b1 t t f I n pn. xhnc (h)Rt d} bar Ct ncr -on It 1t I by,kill, nc N II p J -p d C I rte It h W\ I i 1�1`II me nal . elle the A enol n ns11J S 't necsr-n ctr nn.btA kn (Jr tnnm th':\ m r Jdemand Y uy to Defiul Py u (')I eth onJt m ltd fi 'r doormat I t ohs Calot 'n to c¢Jb Ssmohm tpl > Your Property,but deny 1 c loam eoffiE tyit 0r' .' rt Wemp, tOu It vlr lir I tamd Sister t broA POU III Acid is.IJ tOm 'I t ,food mwt Ike word iil h O r It Au or t rad Lir Y lea n the k k the 9wh -,I red IIx IPI hk l -( )timet t Loch o Your l roti'n C" the fi rn 'n t th ani alt 'W. I. AVII to fo o ( Ient acoll n . 'c t II Ipv t'ImnY 11rP rat w"def 11 Coat 'd i t1 4s[i f 1 IP tin C)Ri eo t h t tndt tin b g dm( '1 eels yolhar xv sl hlemU of SIT in We 'Y ' 'he System I,he It doiUllt-'"iamb( J--Av J PPI llla ' OS 11 Dfi It. A5ef OJ 1P ah11 LI ❑raw y 1 d se 1 q c n ed t i lih til C abl Inn tl t r, I t the I II 't l)0 w h t pet y 1 fh 9. YOUR DUTIES ( )U I th Yat Y a a ill th E y t 1 mnational Mgt ler'thisAkre t nod d f t 1 Fait of ti d P only d r n l Tl rtu y - n ¢ tel V At hunts._ } hot[ su th'r florist(m days after} g ' ! It ounce its h ill c Or fill 0 ur role lb I Vrp uu olds [ In � Illy IhIH 'mlh led lmemt bankLIJA inoV vo ri s +or nvahlnn pas Ou'dbts as rhy mature (Raet<v t tp . meth Sit vnh t mi 'to ua E idi R dtt t1 S(I Ula11r 11 SII Dtaul a -and 1s rnwbYou tit cion 'rah cllth ' tMr dot dal I L titin ray- It n 'tY l'—\kr met' J Locator nm I,] fit Scale tom Your colt l(Yotl It n' vnhro'dC nl'nl t r l t nal t of p f i f Pr,fl adl (q tit sl Id lwl n.c n th torn td'v al Mc to Intel We yhKY tI SI UW Iv tOStr Alt Ito s" Y atoll Yu the,Ae irul 1pl It Nt thtadbNn, Arte You nil) In V- J : ndit s p ��all t Ill ItI I 1 ng h flM1 r m Ito. Ygn nrnt Alterations 1 and(it) }xt Jar Id itunion,i o tsrllta It O :amml t i J S n it We fall to no' A System to Jim System Yon III 'p t'iIic r "Ja L too Sfr tot- eaimed a 1 1 1'np t ➢ sats Svi. IJ Lina O) -A b to'rm P penal y r a by Y r V t' ass b L t f9 ImmJY [,in, fan the no f th -W h l: O r c mat f 1 lo, 1h AI_r o S Y mail 1 1 trim II troo } I pm not-install tholla P r If rah' Ab cert u t t U f t I a -n N tivn I t h1 roc Your tau[lik Jrc - mblI R is Jar shn7mE of theSome.is" t CIoo-1'Csm Ili nSect Ito SJIrD11tY -Imp yroU tl Iletao 11 u or A III'. f m t Ilam d(i)n i r' ) wd rad t an Lina ti it I a rent Fh DeJ it�m r shell be vn1 mm rq vI to J Dollar-IV)pct Na ro dill I ¢1x 1 -y t t fY P pert IA Nor ,t You:hall out,insialed. tow t at a Thdoctiontlive pe¢rat lS//pr see,( t in D Nr I . o Ptall ei SLB IIplu. till mol oho I n n illy home n w avo a nth va with n dom heChh11tIP m rat Vona'. holly elle s the f rh 6y:t I and, the n of a ur m :vmor.and Cut u[ p li Ilh JI that lit"e.P n mv ti ti tiom. Y n I tobtain N tht rt n in n I mom... It n n i m t d - Aute c t (111 Y II p)• II lose, r Aller Y o p l U N Def It P.ptn L We ill m M r r h p of the ask he,1 n r- e f i s ll) ape I flu S n n I,drug all Sy am n You n As I Whom I Tons I i n J Eeg Pshieldb'th S t W 1111 hu 11 IFRNIN 110N (I1mm tt nub Still W Y nym I d' ret L bl 1 ' mer rad P of ray tan a J'n I t t Our h p t Cnn n r tbi Aerc, n( n tin r' Io tM1 Its S Dire upu Jel e f iron JµSyrt (v�Chv ifA the Nitre ray nm wlab > ey ns xiet Yu' Ci phb occurrence of,Cast rDtleIt. WN I too) (i a p h n1n m tip, bsstem all ts'[stall t Yon:I II pay O lar d rtl p Liv and fay-ani tenii t o t f this c Aproemrnt,other Na under[hcircumstances which U here r (')thin al p s n Joe u the,Jam t m elm mak S Il m theSys[ s I not d Io YOU ander ev[m Section 12 or"110. t m D W 'II or thio. 41v n nal fit, the I S « Onre them You 'hall t .pons bl to Oen thSymen, d ItIone all rw op I tet on�"Ire Z5. 11\V< Ami U. r Lord,tax f e J x'Tm for income old p operty w el t t t t I [Ills 1v m r W e ll have (unhtr liability, t0 You. that O Ix .'ball ry ale S i 9 1 (h)f her A Iger" Up o Ou Ib1 S�,ra t m C Yam m y le mft k Ile Agreem a O p m Linea Ne Tellico,Y 0.11p ppJ -n O nv q)p m. in cemento-9th teens c n 'TCa tion t ( I n SII Default, document necessary for L:I buin am Au nb is rte ri all n " IS SYSIF (SHUTDOWNS (a5 95 f,�h and InaJJt. n Ou neht to slwt acnifcann that are unvihmcJ,alb wted Milford m the System, rhe E !b^ n don tire Sys[en f m r t e c Y ate the S st 'I We rnsnuibly en n wI mteT to thereon (collect ly the .SJis Imemn): ( m nv hshloo,that Property conditions or Litt•ibis ofpervert- III Property to hone not permit; iotercomnv.iio I,net neon 16 e m t ts,end rN dnannrnns mqn'ed by under Chir control whether c t order hour cont 1 M2 nhaf th the sale w veritb Our ownershi o interest in the, o oin inn of IIIc System n tCafeN Sh9rdnwn). Dorm•Lime pcndmty of n Set0v ifytitin-and env dooumrnt nnnamn 1 Vt In the the U f i) VV yy Sym J Sys[ Inns¢ Q) I m�Nut fi Y,.a eh II pm nptl n11, l_ I(m) Latt ausv Y t r N 's the SII III, I v}meet (h1 Pr a V or Yp tl ng ntTig w'tM1 torr uprnu t0 S t m (a)Your nJatY rat Y u P I t 1 'anYp uV.1 tion, rnithat - Pnrpms l ort b ncc pmnf[vnAmrons m cntvnlhrm that may."mthe Or Force a for" c 'F 3me S c rDce t4 V w trill t m vftemen eogmt--- PP 11 Sy n n pc' m n g f 1 Yo tnkc vnY emencnc>sd o th rosP'et to the Energy the produced is II a Sy Ytem ()Into vo a hour Div t pt� It r rwnneattoe Sy Y n f 1 m 1 n pry am t f L of T maters.h II he Cu turner to the lot)n het urs I'f n t iTTr uo - moll ion t(1 Fo c 4lojeurt DtF It d Stu�r'1 st Bent, (,i) u"r by< UL 1 t Our n rd action oReaction, h that the 10 5\I E UF'-SbL\li{ VFR(Y (tl Selo. 1'EI en r t f3cei nb re Energy I (hill , t,11 P y t Ile Shoal n c ay u nen ler elect ty to\1 or w(be Sc D t W III " II n Y You 'lFFuyl l s 11 f the ' (Itilly, Y II Pay 1 tl' SI the o Pa n L (eat, to Pan t the pmd c d h it Syv n. f tl no, J ek al loss rah a.pmn n rh Ene daft 4hwd P y r I II equal N sun tee io .J 1 [m rgv in that va i t( Ls m V r 0 P I h n the Sys[ m r a nn.t {to You,in fl o IA h d to l J 'e IoW SedioT A Jim N F ray that lotto Pmprrc Icdrical hint. Encr}y t n n th Ss r m wall h J IicereA t. You in fluorination Produced hisce toes 9,acm e os d Perth o hmd t t )it t lac to <omplia« 'N all y 'r mrne Ito IRI[ fb.('Y m V ggm tw an U 11le y to w ort t are nal ut W ofia aJ w N ; hot it Enere ohm uuu n u pav Li v an u n d c u vk fl Agmt c t ') II he show I Jlimit J ete Id b in ah e f t III n such huWt W(1U P bmr.g un tnNn oral J shall n 1 h xubj cu -p'baton nal I t It u 1 dmI chilli tv e+. Drtem i t Of 0 u t f E errgg b t".Old ha he n prtvlJunnB rcw pm ut Mu't n 1 mA W s rah[ it o tsps bitM Y th which fthe duration hallo bLod(4lduring theInt nvr after rah SnLee hur"p d shall he p yahk- II a nes Iur by Y yr b rs 1 :tint Fxc pr Its Date,on commabol elely III Production d(H)ofte,the firm 'rzr Rer tl e 5 ice 1 pe n Iby ft,N ue fCa Ilton Y henh IlnehLY mYh m IMtc,h-edt Cul p t n IN S�a and daring same p Win th p rcju[ r canal tti a Yl,ren u,to re kreal,gplance rata S 1 bra t year JULhmd pu ant Io Lithium O Nm-S ton is emotions,faro .M1 died ; maty interest 1n III `yatorn fcl Limit S11 Ohhcnton to Defier. WE Do NOT and eighty URC)day, O' lu4mo m r st d1 ler m terminate this \�ARRNT OR GUARANTEE Off Ax1lIFi,'7]'$F�NPkCY PRO]I I3Y Imuncern,vitand reqquire} IIpav the Dermitlmhrbll. _ 1 THE SYSTEM FOR ANY PERIOD OR ANY COST SAVINGS, W n not n ,jilt IG FC/RCE M1fA.IEURE ❑Y o'We a Cbl [ perlorm toy I the ors fat our o public scry a compmr Tod do not ax oo c a ry t blie r a of t tnv or puh[I under Nis Agreement 1 nose f t Force 11 j re F t. s such all led parts will lore court. s n stllpfv Von encrg 1 4 irm c w We are bill suhje I W t excuwd irm h t ,pe forma affected h the Fort M J vrc E'art.('acrdrd Iers It,,rt bO too, oun o u us O 'tg theTerm,You t Jerson I then Yo1 Na[the s pen- I h obi g Y of n<Brenner woPI Lina fns rte J".all nymi rc room chroman tour rhe Jy.tem in b er tel 11 lou nceA ry . h than reachedby t rc Ma E t. F aIle F N strll m v JAn anal energy them lion shell b<sol I, a punsthe acohwnm such Otto f a m the eea condition r ire stun M1csnn 1 the ontml ofN afF r d part htch,by Ne Ul t n Y e ofd f khl o w n .aid tea' mol hall be xpetrcl l mold H OYVNERSHIPOFSNSTEM (1 (h mh ftl S t m ll hall Jwhichby the e t f 1 diligencesuch party 'W mI hav n hblc to s and hold all 0'pen got n the System yam r est' ou.hall I n note t u nc in i Cn4 but not limited t Lieu. h a p1 a rntel wMority pnprt r [ th S11St rthe Syt Interests ceptt. (�N Ermines than tlethl oat NepmT tie rnwlu Whorl rrrhh it led Nei J Sy,j c ate. d C) t d) s p y L% I bl J Yonr Ln I ty Such mhon has bun Jointly n t toted and d I(,e llplurmcJ) failure so 11Man or r I 'ig program Ibr tht F rb" Ill.,,N Systemlee. You v t kcal minimum n Permit.license, I hp,,.,.[V - -t d d rah t h p n h . ado tl e S tent and Svtr in Interests free f all li n s and ncumhmnces In)I'Losainuft t mely and t able comorefti.1 clmrt t ,Main and Tomnry n N :me) label Pr t1 Nnu 1 it Sym Nora then ton q the Liner which rhe So t n n dispute.trika rk stopp 6 mos-down, ek oft thwd earthy k fi a, It gllJoing, aur tl t1�f mP rr 1 t filing h U' You and W bucby ray that a 1J epidemic.c. to nil t e o n 1 on h g of dis(.rbanue. theSY ten Id th Sy t m Interests hell r n Our:oleper or I 1 upen a nJ sh II act of J th,we lub 1 ty of I t cin f tit Utility, N 1 rnt d pPbes or nm he d«med ur th n m l a: I t _t Into IIF really fl t m1. pp 4 L P v It s uCC J by one N ton th rice[d Pry,or Lou, be dhncd by still ld v. It Rom Limned that the alit fN LJn a V P 1mt rl'"T em, d J t oft aIT toI'll,y. S $hull mol be o repair. rcmornol alteration. un as n modernizationof m 1].I IM1tITAT10N ON UABR ITt Vn t d wn I N i ( t W m m ter n�dfnt to.Your Pmlcny O vt 1f A ,, You herb ratio no U and Our 'Y Y n Propert' penonm pnpn} t'purwnvl safUy of pptx n' n or on Your rnpbvety agents,and wmrngors e 6 t atcrss Lina se 1 p ,.,ft)sO N r Pmpen III)Ynu an wld nolo .ole to u -d tb env snrsmct th mI m W n11y(D- .mil operate,and rufl m o it S tem ll o EJho t the'f n O Jar Y ur l ppee tyy a tl is cr torr (c)III rat Y pa t+l x b s A + I to If Our r hos in,a IMS Aerecme n and the S Lie m and i'")wk nal 7 a f Iur o f rhe b n v tin l ed hyo Sy t rad n n On N vlu t f t m 1"5,pcnY or orremaro6l, i ' m, n u cu a the sr « atall t. pert itsc [rat Ile tf S :n ay nr'I e . I' t Amp rl freer u sme fell maintenance repon, - <I tl System The I mgO ' IIs f .r Y d tl I[n o t nn n 1 e d ul mM r f th J I m thus P Arm dual nmion license taaplW a Intel., I �i 11 b IIF for I ht be lost a xYm d l❑ Sv'r m lu l-t open tc pupal} (D I's 1 cam lrlu m p t ery-OJ)do"at)cr[IY raw I courts n pro rad Ux all,time t rn o a dtterm rte in ul enc' 1 r port n if an} f w, pmpeny I ss p + vl inlmt Lir the Sv.'r 1 fit it,,end Of the fm IQt Npec,alt SX i m O J slY v thou 1nN Id b P n ath}Our fatter a to loosen Our negligcnte,of v U. t. k fit g. d n old ms w t I of m or a l mii t n TO,ls, Iallu a of Ne Sy+um ora Swam irmwllmvon no s lap 1 n it filo O pin Syne dJi S t tura et, NOI WITHSTANDING ANY BREACH OF THIS A(aRLEMENT, suchClllmc to I.oll you, he I•nn 1m.mteA.Poppe undersand ohm thformule Systolic hl markedtand }NY" FAILURE OF THE SYSTEDI,OR AW NEGLIGENT ACT 'InifJ $(Jv rp Liv THAT CAUSED ANY' INJURY OR LOSS (WHETHER li \SSICNtIFCI &TRANSFER her > trent tW y :ti Lon ll Lir PROPERTY DAMAGE. PERSONAL INJ(1RV OR DEATH) 'f0 an f ( i en Pan11 this At (� rot al th Sy:}m 1 t x1 ANYONE, WE AND YOU A( REE THA'C UNLESS SUCH e tfi utY r n1.- t W t y it IC hna Iur t oto O rrighr. Jer ih YCe n t We III 1 etlnrliability'Or bfgiwuaJ INJURY OR LOSS WAS CAUSED BY A PARTY'S GROSS di:Am eta up nNe IRct ens of I s 6nm t IbltrrJ���fi n- NEGLIGENCE, FRAUD, OR WILLFUL INJURY, SUCH Y it cal p orda V. 'III thr xy (L))Jay tin write nntncc t t t pr pi 1't PARTY'S LIABILITY ARISING OUT OF OR RELATING TO 11 ole 0I YOVP Pn Thislnu mw sl IIIel1 then of ,the v PSW punt ase rt Flee P'P rp nyT tfrrr )antN tin pr'd Fte Of FFIIS AGREEMENT SHALL IN NO EVENT EXCEED THIS Icor tmishr. Youwll al' pnwidu aJJit m l W mwi urcem'dinP,1 Z10,, DGPAUL'F PAYMENT. YOU .4NU WE AGREE THAT '7H[S Transferee that wr rezmnably reyuen. lieu will.reyuest that Prnpeny'F1,I'st AMOUNT IS A FAIR REPRESENTATION OF THE; DAMAGES agree t writing an Us ohm Pmpeny Frnrs4nv wit nssunmc Ymv o ligan( s under THAT YOU OR WE EXPECT TO INCUR IN THE CASE OF ANY the "'Then rt enr. 'in p r 1'r n:f tee xh II n it la 3uth mqr mm m u htfun the d t You upen (I Vt vii rl l W Aueml nL th'[Pmocny'Crn t feat Is INJURY OR LOSS FIEREUNDER. L deyuary 'red t r d -t moon a Yn r klib ii, u d i(IiS Ac xn.m 4 r NO CLAIM SHALL BE MADE BY YOU AGAINST US OR ANY Yn pony hamkre -fus. w vsdun t Y r bl t on. u Acr tliis Agrta em. We a +•n,�, Workers' Compensation Insurance Affidavit: Sand¢!ea s/C®nksaet®rslEfiestsacdans/Plumbers AyyUcaant Informatiomm Please PaiBt Legibiv Name (s,uinessiorganizatiamAndividual): Vivint Solar Developer, LLC Address:4931 North 300 West City/State/Zip:Provo, UT 84604 Phone#:801-704-9389 Are you an employer? Check the appropriate box: Type of project(required): 1.® I am a employer with 10 4- E] I am a general contractor and I employees (full and/or part-time). : have hired the sub-contractors G_ E] New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. [] Remodeling ship and have no�Pto ees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9 Building addition [No workers' comp. insurance comp. insurance.[ required.] 5. E] We are a corporation and its 10.0 Electrical repairs or additions officers have exercised their C repairs or additions 3.❑ I am a homeowner doing all work 11.0 Plumbing myself. [No workers' comp. right of exemption per MGL 12.E] Roof repairs insurance required.] c. 152, §1(4), and we have no employees. [No workers' 13.0 Other comp. insurance required.] 'Any applicant that checks box p I must also Callow the section below showing their workers'compensation policy hr[a nmation. t Homeovsners who submit this affidavit indicating they ace doing all work and then him outside contractors must submit a new affidavit indicating such. Con tractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must pmvide their workers'comp.policy number- I arse an employer that is providing workers'compensadoan insu ante for my employees. Below is thepolicy andjob site information. Insurance Company Name:lk ew Hampshire Insurance Comany Policy# or Self-ins. Lic. #:02934'(2228 Expiration Date:1111-,0-.1-14 Job Site Address: ' C C 'p�1 City/StateMp: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). az lire to secure coverage as requires ectlou" o c. ISZ can Iead to the imposition of criminal --- of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of tip to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. Ida hereby/�w/�and. M pa and penalties ofperfury that the information provided above is true and correct Suture: 4 A91-e Date' Phone#: 801-704-9389 Official use only. Ido not write in this area, to be completed by city or town official. City or Town: Penmit/d.icense # Issuing Authority(circle one): 1.board of health 2. Building Department 3. City/Town Clens 4.Electrical Inspector 5. Plunnbiug Inspector 6. Other Contact Person: phone#• µ' 10 lark Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor registration Registration: 170848 Type: Supplement Card VIVIiNT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, LIT 84604 Update Address and return card. Mark reason for change. ;i ,pi Bmia�misnnu [j Address [71 Renewal F-] Employment Lost Card ,.a �✓ne l�mmarsae,oxruaca��z,s�i�?na �- f£ce of Consumer Affa(rs&Business Regulation License or registration valid for individul use only -w E 1.NPROVEM'E 5T CON•TRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation egistration:. 170848 Type.: 10 Park Plaza-Suite 5170 Expiration: 7;Sf201E Supplement Card Boston,MA 02116 VIVINT SOLAR DEVELOPER LL-- JAMES L;.JAMES SHERMAN 4931 NORTH 300 VNEST PROVO, UT 84604 Undersecretary Not valid without Signature -- Massachusetts -Department of Public Safety Board of Building Regulations and Standards Con,tructiun Supcn ism License:CS-0:525-4 Bt P!A`AEi-YSII' - x SAUGU'S JJA 011,LO Expiration Commissioner 08128/220'f4 f L 4931 North 300 West Structural Group Provo,UT 84604 P: (801) 234-7050 Scott E. Wyssling, PE Head of Structural Engineering scoff.wyssling@a vivintsolar.com July 24,2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Tachuk Residence 1 Moffatt Road, Salem MA AR#3195373 10.20 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 8 dimensional lumber at 20" on center. Collar ties were not present during the inspection. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached ZEP calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 34, 12 and 2 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure"B", Zone 2 per(ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivi t. ~ Page 2 of 2 B. Loading Criteria 10 PSF=Dead Load roofing/framing 40 PSF=Live Load (around snow load) 5 PSF= Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "ZEP Code Compliant Installation Manual', which can be found on the ZEP website (zepsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 lbs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation,the pullout value, utilizing a penetration depth of 2 1/2", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 Yz'with a minimum size of 5/16"lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every third roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than three (3) rafter spaces or 60"o/c,whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. ery truly yours, ��ZH 0F'NgS'r9 �.e E CyT Scott E. Wy ling, o ciw ti MA License No. >o FGis7 FSSIONAI bAbOQ'9�'. JUNCTION BOX ATTACHED TO OS OF 1-PVC CONDUIT ARRAY USING ECO HARDWARE TO FROM JUNCTION BOX TO ELEC PANEL KEEP JUNCTION BOX OFF ROOF Q) -—- -—-—- U I I � _ o �w cna om � f' I adz -No O D ti U PV SYSTEM SIZE: 10.20 kW DC O 1 , I I � E ) I I C m v/ or= < mo N � U Z m m m > Z m Q_ N N Q SHEET I , NAME: UJ Z ~ J 1 ( d L---- ---- --- --� SHEET NUMBER' t (40)Tnna Solar TSM-255 PA05.18 MODULES WITH A — PV INTERCONNECTION POINT, PV SYSTEM SITE PLAN O Enphaw M215-60-2LL-S2n-ZC MICRO-INVERTER LOCKABLE DISCONNECT SWITCH. T— MOUNTED ON THE BACK OF EACH MODULE ANSI METER LOCATION, SCALE: 3/32"_ 'I'-O" 8 UTILITY METER LOCATION a V CIRCUIT 93: V 11 MODULES C 1p me mw y/LQ7 ��2 O Roof Section 1 � v z Roof Azimuth:232 Y^1cl o Roof Tilt:34 maS' C /—CHIMNEY COMP.SHINGLE-----\ CIRCUIT#2: n COMP.SHINGLE-----\ 13 MODULES .---ROOF VENTS) am a m $ ^n TIE INTO METER# y w U 588 6558 z to > � to Roof Section 2 w to z m RadAft, 32 w z RooFTh 1212 to ¢ <3 PVCIRCUIT#1. to ia0 16 MODULES EZ SHEET NAME: UBBER O ZQ O4�01 � tY a SHEET Roof Section 3 NUMBER: RRoofAarn k142 PV SYSTEM ROOF PLAN N SCALE: 1/8" = 1'-0" a MOUNTING PV3.0 DETAIL CLAMP V Q $ PV MODULES, TYP. MOUNT SEALING WASHER OF COMP SHINGLE ROOF, y�o PARALLEL TO ROOF PLANE OWER SUPPORT �L¢' ��z adz FLASHING 4,;,._;.:. �m.y;.:.;,:.:.. U L U � co LAG PV ARRAY TYP. ELEVATION NOT TO SCALE CLAMP ATTACHMENT • NOT TO SCALE p� o b M •e n P AT Ma T = CANTELEVER U4 OR LESS a L=PERMITTED CLAMP SPACING F+A"�raxT SEE CODE COMPLIANT LETTER FOR 5 m "' MAX ALLOWABLE CLAMP SPACING. u0i PHOTOVOLTAIC MODULE COUPLING CLAMP > ' E rc K m wwzm w Z r3� z z <¢ E o SHEET NAME: F U) Z J m mwTmm umnc O F p PV SYSTEM MOUNTING DETAIL SHEET NUMBER: MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE �1 ccd NOT TO SCALE l Inverter Ratings(Guide Section 4) Inverter yourseNel Enphase M21 S60.21A_-52x-ZL Conduit and Conductor Schedule MODULE DETAIL Ma.oC Val..an, 45 value TeeM�ne sulptim Was Gouge xotcnnduGnrs Conduit Type Lineup si:e /I� Max Power®40°C 215 Watts t e nee-THWN�2 12 AWG =4 � NIA-Free All •DNominal AC Voltage 240 VoltsTrina Solar TSM-255 PA05.18 - Max AC Cumene 09Pmps1 mued(EGCIGECI aPWG NIA-Free Nr Vup an SOLAR MODULE Max OCPO Rating 20 Amps 2 10 AWGMax Number et Panelv(SirWit 1] 2 nd OAWGde ] AAWG A, ONOTES FOR INVERTER CIRCUITS(Guide Section8 ad 9l: eAwc pp3 nd �aom 1)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS - (1)a Enpha98 M21S60-2LL-SPX-ZC SWITCH MEET THE REQUIREMENTS? PV Module Ratings @ STC(Guide Section 5) zi i ModeMake/Model Irma Solar TSM255PA05.+8 MICRO-INVERTER AT YES NO XNA l m~ EACH MODULE.ATTACHED Max Power-Point Cument(imp) 8.36MAm WITH ECO HARDWARE 2J IF GENERATION METER REQUIRED.DOES THIS METER Max Power-Point Voltage lVmp) 305 Y^rq0 SOCKET MEET THE REQUIREMENTS? Open-timet Voltage(Voc) 379 U YES NO XNA short-circuit Current gsc) 8.92 2 3.)SIZE PHOTOVOLTAIC POWER SOURCE(Di CONDUCTORS Max Series Fuse QCPD) 15 U BASED ON MAX CURRENT ON NEC 69053 SIGN OR OCPD Nominal Maximum Power at STC(Preal 255 CU f- MICROINVERTERCONNECTION _ RATING AT DISCONNECT. Maximum system Voltage 1o000ecysoo(uL) 0 TO ENGAGE TRUNK CABLE 4.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Vold Temperature Coelatlent ^ TO INVERTER OCPD AMPERE RATING Sade Guide Season 9). V 5.I TOTAL OF 3 INVERTER OCPD(s1.ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide Section 6 and 6 and Appendix En, PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN 1.)Lowest expected ambient temperature based on ASHRAE minimum mean extreme Nfi BARE CU GROUND NEC 690.64(BX2XxU7 XYES NO dry bulb temperature for ASHRAE location most similar to installation location: -19°C (GROUNDING ARRAY) Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%dry bulb temperature for ASHRAE location most similar to installation location: 39°C Sign for inverter DICED and AC Disconnect 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47°C in the United States(Palm Springs,CA is 44.1°C).For less than 9 current-carrying conductors Solar PV System AC Point of Connection in mor-mounted sunlit eemuit at least 0.5^above root and using the outdoor design AC Output Current 36.000000 Amp. temperature of 47°C or less(all of United States). Nominal AO Voltage 1 2401 VOLS a.)12 AWG 90-0 conductors are generally acceptable for modules with lsc of 7.58 Amps �< PV CIRCUIT 1: 16 MODULES/PARALLEL THIS PANEL PED By MULTIPLE Bounces or less when protected by a 12-Amp or smaller fuse. b.l 10 AWG.90°C ccondudorre e agenerally acceptable for modules with Inc of 9.6 Amps (UTILITY AND SOLAR) or less when protected by a15-Am m or smaller fuse. �� ,6 • • • O O 1 NOTE:NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY `a E 1.0 ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR •� 2 . se is as de ENVOY BOX de PV CIRCUIT 2: 13 MODULES/PARALLEL N I I 0 O m m 13 • • • O i Nor 0 c 1 I MURRAY z m x j COMBINER > w E 1.0 PANEL 125A/240V tode • • • LWO04NR SIEMENS us w z m \yOC-p0 OR EQUIVALENT 60A/240V SIEMENS ¢ ¢ , ; \GAG 1 UNFUSED 60A(240V w h ¢ s I PO\�.2Q NEMA3 FUSED NEMA3 z E o PV CIRCUIT 3: 11 MODULES/PARALLEL I o\F SREC/ANSI LNF222R OR GF222R OR EXISTING SHEET I TSO\ , METER EQUIVALENT EQUIVALENT ENTRANCE NAME: 4\�>' O CONDUCTORS 11 • • • O O \O,p' 20A RATED:200A W Q +5A z 7i 0 15A M SUPPLY-SIDE A Q ✓• • • • J• x/, I soA SOLAR TAP C3 I NEng..+zlM SHEET _ NUMBER: \\ MILBANK VISIBLE/LOCKABLE l pgNEL240V1200A O a JUNCTION BOX 2 \ 3 100A OR '3 'KNIFE'A/C 3 3 WITH IRREVERSIBLE \\ EQUIVALENT DISCONNECT TC EXISTING NEC 2014 Compliant GROUND SPLICE E 1.0 \ E 1.0 U5934-XL-BLG E 1.0 E 1.0 E 1.0 LOAD-CENTER Il.l T Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: John Tachuk Project Address: 1 Moffatt Rd,Salem MA A.System Description: The array consists of a 10.2 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are (40) 255-watt modules and(40)215-watt micro-inverters,mounted on the back of each PV module.The array includes (3)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Emhbdum Solar. B.Site Design Temperature: (From Boston Logan INTL ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Dcsilm Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A. System Description: 1.Roof type: Comp. Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecollbrlum Solar b.Product Name. EeoRall e Total Weight of PV Modules and mounting hardware. 1880 lbs d.Total number of attachment points: 87 e.Weight per attachment point: 21.6 lbs f Maximum spacing between attachment points: * See attached engineering talcs g.Total surface area of PV array: 704.4 square feet h.Array pounds per square foot: 2.66 lbs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (20)modules,(42)attachments 29.09 pounds -Roof section 2: (8)modules,(30)attachments 12.53 pounds per square foot -Roof section 3: (6)modules,(15)attachments 18.8 pounds per square foot vivint. . 3. Electrical Components: A.Module (UL 1703 Listed) Qty Trina TSM 255-PA05.18 40 modules Module Specs Pmax-nominal maximum power at STC - 255 watts Vmp-rated voltage at maximum power - 30.5 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.36 amps Ise-rate short circuit current - 8.92 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-2LL-S22 40 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 3 PV circuit 1 - 16 modules/inverters (20)amp breaker PV circuit 2 - 13 modules/inverters (15)amp breaker PV circuit 3 - 11 modules/inverters (15)amp breaker 2011 NEC Article 705.60(6) D.Electrical Calculations 1.PV Circuit current PV circuit nominal current 14.4 amps Continuous current adjustment factor 125% 2011 NEC Article 705.60(B) PV circuit continuous current rating 18 amps 2.Overcurrent protection device rating PV circuit continuous current rating 18 amps Next standard size fuse/breaker to protect conductors 20 amp breaker Use 20 amo AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed V above the roof surface Add 22°C to ambient 2011 NEC Anide 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% - 2011 NEC Anlde 705.60(8) Adjusted PV circuit continuous current 25.3 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 9 conductors Conduit fill derate factor 70% 2011 NEC Anicle 705.60(B) Final Adjusted PV circuit continuous current 36.2 amps Total derated ampacity for PV circuit 36.2 amps Conductors (tag2 on 1-line)must be rated for a minimum of 36.2 amps THWN-2 (90°C)#10AWG conductor is rated for 40 amps (Use#10AWG or larger) 2011 NEC Article 705.60(8) 4.Voltage drop(keep below 3%total) 2 parts: 1.Voltage drop across longest PV circuit micro-inverters (from modules to j-box) 2.Voltage drop across AC conductors (from j-box to point of interconnection) 1.Mrco-inverter voltage drop: 0.31"/o The largest number of micro-inverters in a row in the entire array is 8 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.31 %. 2. AC conductor voltage drop: =I x R x D (=240 x 100 to convert to percent) = (Nominal current of largest circuit)x (Resistance of#10AWG copper)x(Total wire run) = (Circuit 1 nominal current is 14.4 amps)x (0.0012652)x(210 . (240 volts) x(100) 1.58% Total system voltage drop: 1.89% vivint. • - t EcolibriumSolar Customer Info Name: Email: Phone: Project Info Identifier: 6348 Street Address Line 1: Street Address Line 2: City: State: Zip: 01970 Country: United States System Info . Module Manufacturer: Trina Solar Module Model:TSM-255 PA05.18 Module Quantity: 40 Array Size(DC watts): 10.2 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight:44.8 lbs Module Length: 65.5 in Module Width: 39.625 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load-Upward: 820 Ibf Lag Bolt Design Load-Lateral: 300 Ibf EcoX Design Load- Downward: 493 Ibf EcoX Design Load- Upward: 568 Ibf EcoX Design Load- Downslope: 353 Ibf EcoX Design Load- Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-Ib Module Design Moment—Downward: 3655 in-Ib Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 Plane Calculations (ASCE 7-05): 1 Roof Type: Composition Shingle Average Roof Height: 25.0 ft Least Horizontal Dimension: 16.0 ft Roof Slope: 34.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.66 0.66 0.66 Roof Snow Load 22.2 22.2 22.2 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -17.1 -20.1 -20.1 psf Net Design Wind Pressure Downforce 16.0 16.0 16.0 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -17.1 -20.1 -20.1 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf Aso Load Combinations Description Interior Edge Corner Unit Dead Load 2.5 2.5 2.5 psf Snow Load 22.2 22.2 22.2 psf Downslope: Load Combination 3 11.7 11.7 11.7 psf Down: Load Combination 3 17.3 17.3 17.3 psf Down: Load Combination 5 18.1 18.1 18.1 psf Down: Load Combination 6a 25.5 25.5 25.5 psf Up:Load Combination 7 -15.9 -18.9 -18.9 psf Down Max 25.5 25.5 25.5 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 64.6 64.6 64.6 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 21.5 21.5 21.5 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 42.5 42.5 42.5 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 14.2 14.2 14.2 in IBM NMI ISM M - - \ \ \ ƒ � . . ■ D © � Plane Calculations (ASCE 7-05): 2 Roof Type: Composition Shingle Average Roof Height: 15.0 ft Least Horizontal Dimension: 13.0 ft Roof Slope: 12.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 1.06 1.06 1.06 Roof Snow Load 35.6 35.6 35.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 9.4 9.4 9.4psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.5 2.5 2.5 psf Snow Load 35.6 35.6 35.6 psf Downslope:Load Combination 3 7.8 7.8 7.8 psf Down: Load Combination 3 36.5 36.5 36.5 psf Down: Load Combination 5 11.8 11.8 11.8 psf Down: Load Combination 6a 35.0 35.0 35.0 psf Up:Load Combination 7 -14.5 -24.9 -38.1 psf Down Max 36.5 36.5 36.5 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 49.1 49.1 49.1 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 16.4 16.4 16.4 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 29.7 29.7 29.7 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 16.0 16.0 16.0 in Max Cantilever from Attachment to Perimeter of PV Array 9.9 9.9 9.9 in Layout it All k x � w a�"a .ad h y Naq r 'yti ry Skirt e Coupling 0 Clamp Plane Calculations (ASCE 7-05): 3 Roof Type: Composition Shingle Average Roof Height: 15.0 ft Least Horizontal Dimension: 12.0 ft Roof Slope: 2.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 1.0 1.0 1.0 Roof Snow Load 33.6 33.6 33.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -17.5 -27.0 -37.6 psf Net Design Wind Pressure Downforce 6.9 6.9 6.9 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -17.5 -27.0 -37.6 psf Design Wind Pressure Downforce 6.9 6.9 6.9 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.5 2.5 2.5 psf Snow Load 33.6 33.6 33.6 psf Downslope: Load Combination 3 1.3 1.3 1.3 psf Down: Load Combination 3 36.0 36.0 36.0 psf Down: Load Combination 5 9.4 9.4 9.4 psf Down: Load Combination 6a 32.8 32.8 32.8 psf Up:Load Combination 7 -16.0 -25.5 -36.1 psf Down Max 36.0 36.0 36.0 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 49.7 49.7 49.7 in Max Spacing Between Attachments With Rafter(fruss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 16.6 16.6 16.6 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 30.1 30.1 30.1 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 16.0 16.0 16.0 in Max Cantilever from Attachment to Perimeter of PV Array 10.0 10.0 10.0 in Layout 1011 1 Skirt Coupling 0 Clamp Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 1792 lbs Weight of Mounting System: 174 lbs Total System Weight: 1966 lbs. Total Array Area: 721 ft2 Distributed Weight: 2.73 psf Number of Attachments: 87 Weight per Attachment Point: 23 lbs Bill Of Materials Part Name Quantity ESEG01 CLASA EcoX Clamp Assembly 87 ESEGOICOASA EcoX Coupling Assembly 47 ESEG01 SKKTA EcoX Landscape Skirt Kit 12 ESEG01 SKKTA EcoX Portrait Skirt Kit 4 ESEG01 CPKTA EcoX Composition Attachment Kit 87 ESEG01 ELASA EcoX Electrical Assembly 3